Rad Quality 4

Ace your homework & exams now with Quizwiz!

Which of the following would be used to minimize magnification? -

1 &3 (smallest OID possible ,longest SID)

Spatial resolution increases with how many blurs?

3

MF= SID/SOD whats the answer? SID=40 OID=10

40(SID) - 10(OID)= 30(SOD) 40/30= 1.3MF

What is the formula for magnification factor?-

All 3

Focal spot decreases with _______??

All of the above

What happens with geometric unsharpness? ______??

All of the above

Control motion=_________?

All of the above.

What needs to increase to improve radiographic image quality? -

Increase SID (longest SID possible)

When you decrease the tube angle, shape distortion will be ___more or less_____.

Less

What are two ways to minimize magnification?

Long SID, Small OID

What are the formulas for Magnification Factor?

MF= object size (OS)/ image size(IS) MF=SID/SOD

________SID and _______ magnification. *______related.

More SID, less magnification. Less SID, more magnification. INVERSELY

Resolution improves when _____ decreases.

OID

Resolution is improved with? -

OID decreases, increasing your SID

What is used to minimize magnification? -OID -SID -Focal Spot

ONLY OID & SID

How do you reduce distortion?

Place the image and IR parallel to IP

Resolution improves when _____ increases.

SID

What do you increase to improve image quality?

SID

True/False: Overall magnification is not distortion.

True

True/False: Unsharpness is NOT effected by kVp.

True

Which of the following may be used to control motion during a radiographic examination?

all 3 (shortest time possible, precise instructions to pt., immobilization devices)

Geometric un sharpness decreases as? -

all of them

As focal spot size decreases-

all of these

Which of the following can be done to help compensate for an angled part? -

angle the tube and the IR

What two things can you do to compensate for part angulation?

angle tube and IR

Degree of resolution______?

bony trabecular pattern

When evaluating the degree of resolution on an actual radiograph image an effective image tissue to analyse is?

bony trabecular patterns

The best method for controlling motion when the patient is unable to cooperate is to? -

decrease your time, while maintaining same mAs

Factors affecting recorded detail include? -

focal spot size

What factor effects recorded detail?

focal spot size

What happens to your image when your part is not lined up to CR?

foreshortening

Which one of the following occurs when the part is improperly aligned with the CR? -

foreshortening, (or elongated)

Materials with ______ will attenuate more x-rays.

high atomic #

When OID increases, magnification ________.

increases

What motion always has a negative impact?

involuntary motion

Which of these can negatively impact recorded detail? -

involuntary motion

Unsharpness is not affected by which of the following? -

kVp

An examination of body parts with large inherent OID warned a ________ whenever possible? -

larger SID

The greater the SID the -

less magnification

when improving radiographic quality you want to use long _____possible, and use short _____ possible.

long SID and short OID

What is the best way to reduce magnification? -

long SID, small OID

What happens if you increase your OID? -

magnification increases

The three primary geometric factors affect image quality are? -

magnification, distortion, focal spot size

What are the 3 geometric factors?

magnification, distortion, focal-spot blur

Whats the best method to control motion?

maintain mAs by decreasing time

What do you do with your CR when you want to reduce distortion?

make CR parallel to IR

How do you compensate for an exam with lots of OID?

make more SID

Which of the following human immobilizers is used to keep the patient in position while the following people are available? -

male relative to hold

Xray beam is divergent which means ______ is impossible.

minification

Because x ray beam is divergent-

minification is impossible

What is the formula for object size?

object size= image size (SOD/SID)

what are the factors that effect distortion?

object thickness, object position, object shape

What effects subject contrast? -

patient thickness

Proper alignment ___________?

perp and perp

Properly alignment is achieved when the CR is ______ to the part and ______ to the IR. -

perpendicular, perpendicular

What effects subject contrast?

pt thickness

Patient thickness affects image quality by which things? -

radiographic contrast, magnification, and focal spot

Pt thickness effects quality by effecting what 3 things?

radiographic contrast, magnification, focal spot blur

Motion of pt, xray tube or IR reduces __________.

radiographic quality

What radiographic qualities determine sharpness? (2)

recorded detail & distortion

Which of the following radiographic qualities determine the sharpness of detail in a finished radiograph? -

recorded detail & distortion

Increasing SID does what things?

reduce magnification, improve spatial resolution, reduce pt dose

When the pt is reversed what do you do to the tube?

reverse

If the position of the patient is reversed, the direction of the tube angle must be _______ to maintain the same relationship. -

reversed

If you decrease your tube angle which of the following will occur? -

shape distortion will decrease

Distortion is the best representation of? -

size & shape

Distortion is a misrepresentation of ________ &________.

size and shape

___focal spot size reduces penumbra

small

What effects shape distortion?

tube angulation

What is the correct name for the loss of recorded detail due to the use of a large focal spot? -

unsharpness

________-loss of recorded detail due to large focal spot.

unsharpness

What do you use when you want to reduce focal spot blur?

use smallest focal spot

How do you reduce focal spot blur? -

using smallest focal spot as possible

Which of the following affects shape distortion? -

x-ray tube angulation


Related study sets

Connect: CH2, Connect Ch:3, BPI02, CH:4, CH: 5, BPI06, BPI07, CIS CH:6, CIS CH:7, CIS: CH 8

View Set

Incident Handling - Mobile Security and Privacy

View Set

Music Appreciation Final Exam Study Material

View Set

PassPoint: Pharmacology and Medication Management

View Set

Cost Accounting Exam #1 MC (Conceptual)

View Set

Intro to Marketing Exam 1 (University of Iowa, Nancy Abrams)

View Set