test 1

Ace your homework & exams now with Quizwiz!

the cross secrional area of a 4awg thhe/thwn copper condutor is square inches

.0824

where a branch circuit is rated at 20 amps the smallest circuit conductors that be installed are awg copper

10

generally nec definitions are located in artcle

100

the circular mil area of a 10 awg bare copper conductor is cmils

10380

chapter 1 in the nec contains articles 100

110

where a branch circuit is protected with a 20 amp fuses the smallest circuit conductors that can be installed are awg copper

12

where a branch circuit is rated at 20 amps the smallest circuit conductors that can be installed are awg

12

ignoring the effects of voltage drop a 20 ampere branch circuit requires conductors

12 awg copper

branch ciruitts that serve a are reqired to be rated at 20 amperes where installed in a house

123

receptacles that are located in can be connected to a small appliance branch circuit in a house

123

which of the following actual readings would be considered to be considered to be nominal 240 volts

123

refer to article 100 definition for continuous load in the nec according to 210.19 and 210.20a times the current drawn by the load

125

refer to article 100 definition for continuous load in the nec according to 210.19 the branch circit conductors for a continuous load shall be sized at not less than times the current drawn by the load

125

refer to article 100 definition for continuous load in the nec according to 210.19 the minmum branch circuit conductor size before the applicatin of any adjustment or correction fators shall have an allowable ampacity equal to or greater than the noncontinuous load plus percent of the continuous load

125

refer to the article 100 definition for continuous load in the nec according 210.20a the over current protection for a continuous load shall be sized at not less than of the current drawn by the load

125

which of the following actual readings would be considered to be considered to be nominal 120 volts

125 114

which of the following actual readings would be considered to be considered to be nominal 120 volts

128 110

if a wire 375 feet long has 500 ohms of resistance what is the resistance of 10oo feet of the same wire

1333 ohms

where a branch circuit is protected with a 15 amp circuit breaker the smallest circuit conductors that can be install are awg copper

14

where 10 awg thhn thwn copper circuit conductors are connected to 20 amp circuit breaker the circuit is considered to be a amp branch circuit

15

where 12 awg thhn thwn copper circuit conductors are connected to 20 amp circuit breaker the circuit is considered to be a amp branch circuit

15

3 hours 20 minutes -1 48 minutes

1hr 32min

what is minimum number of 20 ampere branch circuits for small appliances required in a residence

2

the nec requires one separate ampere receptacle branch circuit for bathroom receptacles because cord connected appliances used in residential bathrooms such as curling irons and hair dryers use a lot of current

20

the nec requires two separate ampere receptacle branch circuits for kitchens because cord connected appliances used in residental

20

where 10 awg thhn thwn copper circuit conductors are connected to 20 amp circuit breaker the circuit is considered to be a amp branch circuit

20

which of the following actual readings would be considered to be considered to be nominal 208 volts

206

section of the nec states that a refrigerator may be supplied by a separate 15 amp circuit

210.52 b 1 exception 2

where 6 awg thhn thwn copper circuit conductors are connected to 25 amp circuit breaker the circuit is considered to be a amp branch circuit

25

which of the following actual readings would be considered to be considered to be nominal 240 volts

250 233

3 hours 20 minutes +1 48 minutes

308

the code reference for gfci protetion of receptacles in commercial garages is found at

511.12

for a single family dwelling with a total of 3500 square feet of occupied area the minimum number of 15 ampere lighting branch circuits is

6

you timed your helper and it took him 2 1/2 hours to dig a trench 20 feet long. if you get another helper who will work at the same pace how much time will it take both of them to big an additional 100 feet

6 hours 15 minutes

the of a conductor must not be less than the rating of the over current device protecting theconductor

ampacity

circuits that have a nominal voltage rating of 120 volts may have an actual operating voltage of

any of these

in construction of commercial and industrial the quantity and rating of electrical circuital circuits is usually designed by the

architect

point z is

arrow

article 210applies to branch circuit calculations for the purpose of determining the size of a service or feeder are covered in

article 220

how is wire diameter expression the awg standard

as a whole number

in a dwelling such as your house how many 20 branch circuits are required by the nec to supply power to an area where a clothes washing machie is to be plugged into a receptacle

at least one

how many 20 amp small appliance branch circuits are reqired by the nec to supply power to receptacles in dwelling kitchens such as in your house

at least two

wire sizes 4/0 and smaller are expressed in

awg

residential boat hoist motor is required to be gfci protected

both 1 2

nominal voltage includes a range of actual circuit voltages that are the nominal voltage

both a and b

the nec considers installation under a covered walk way or canopy to be a location

damp

when calculating loads to determine the size of a 120/240 volt 1 3 wire service the lighting load in amps is calculated by the lighting load in volt amps by 240 volts

dividing

the nec require at two 20 amp small appliance branch circuits to supply power to counter top receptacles in kitchen of a house

does

the nec require at least two 20 amp small appliance branch circuits to supply power to counter top receptacles in commercial resaurant kitchens such as dair queen

does not

the nec considers an installation inside a building to be a location

dry

in construction of one and two family dwellings the quantity and rating of electrical circuits is usually designed by the

electrician

which if these trade size 1/2 inch raceways has the the smallest inside diameter refer to the appropriate table among those shown in nec chapter 9 table 4

eletrical nonmetallic tubing

the NEC definition for is electrically connected to or is a source of voltage

energized

all 120 volt 15 or 20 ampere receptacles in unfinished basements in homes must have

gfci protection

although the nec contains many exceptions in general the ampacity of the branch circuit conductors protective dev must have an ampacity that is or equal to the rating of the ocpd

greater than

gfci is an abbreviation stands for

ground fault circuit interrupter

point x is

hook

wire sizes up through 4/0 are expressed in American wire gauge awg wire sizes larger than 4/0 awg are expressed in

kcmil

although the nec contains many exceptions in general the rating of the branch circuit conductors protective device must have a rating that is or equal to the ampacity of the brsnch circuit conductors connected to it

less than

the diameter of wire is usually provided in a unit of measurement called a

mil

nec stands for

national electrical code

nfpa stands for

national fire protection association

the code reqires which of the following residential to be gfci protected

neither 1 2

branch circuits that serve a are required to be rated at 20 amperes where installed in a school

neither 123

are at least two 20 amp small appliance branch circuits to supply power to counter top receptacles in commercial restaurant kitchens such as dairy queen

no

in a dwelling does the nec permit the circuit installed to a washing machine receptacle to also be connected to the light over the washing machine

no

how many 20 amp small appliance branch circuits are required by the nec to supply power to countertops in commercial restaurant kitchens such as pappa bar b que

none are required

the to9tal number of electrician working for one electrica company is 123. another electcal company has 40 fewer electricaians how many electricians work for the second company

none of there

where 4 awg thhn thwn copper circuit conductors are connected to 30 amp circuit breaker the circuit is considered to be a amp branch circuit

none of there

point w is

rim notntch

point y is

star

branch circuits are rated rated according to

the ampere rating of the overcurrent device

the nec defines a branch circuit as

the circuit conductors between the

the definition of s branch circuit is

the circuit conductors between the final over current device protecting the circuit and the outlet

when calculating loads to determine the size of aservice the lighting load in volt amps is calculated by multiplying the floor area times the value shown in table 220.12 of the nec

true

when circuit conductors larger than the minimum required by the nec are installed the rating of a branch circuit is

unchanged

according to nec section 240.4b if the ampacity of a conductor does not match up with a standard fuse rating what are you allowed to do

use the next higher standard rating

if the apacity of a conductor does not match up with a standard circuit breaker size you are allowed to according to section 240.4 b in the nec

use the next higher standard size breaker

the nec considers an installation underground to be location

wet

are at least tow 20 amp small appliance branch circuits required by the nec to supply power to counter top receptacles in residential kitchens

yes

does the nec permit a 120 volt receptacle for a gas range to be connected to a small appliance branch

yes

figure 108.016 shown above is a residential kitchen a refrigerator will be installed in this residential kitchen and will be located in front of and connected to receptacle 11 does the nec permit receptacle 11 to be connected to a circuit that is not a small appliance branch circuit

yes

refer to figure 108.014 this kitchen is in a house and receptacle 8 is used for gas range control power. does the nec permit receptacle 8 to be connected to one of the 20 amp small appliance branch circuits

yes

refer to figure 108.014 this kitchen is in a house. does the nec permit receptacle 11 to be connected to a circuit that is not one of the 20 amp small appliance branch circuits

yes

refer to figure 108.014 this kitchen is in a house. does the nec permit receptacle 11 to be connected to one of the 20 amp small appliance branch circuits

yes


Related study sets

👾 Code.org Unit 3: Animations and Games Lessons 1 - 12

View Set

Ch 40: Nursing Assessment: Musculoskeletal Function

View Set

J'ai un chat - je n'ai pas de chien!

View Set

AP COMP GOV: Mexico VS UK VS Russia

View Set

Physiology - Questions - Block 3 - BRS - Renal

View Set