35 humidity control
The drainage outlet for a humidifier should be at least ___, the open drain .
1 " above
Human comfort requires a relative Humidity between
30 and 50%
Humid air in
A
Warm air duct
A
Water pan
A
Special chemicals remove moisture from the air by
Adsobrtion
A category of humidifiers that project small water droplets into the air, either by mechanically flinging water or by forcing water through a nozzle
Atomizing humidifier
Drain connection
B
Humidstat
B
On off switch
B
Pump
B
A type of central humidifier that is installed between the supply, returning the plenums
Bypass humidifier
Air outlet
C
Humidistat
C
Water supply connection
C
Water vapor
C
Capillary tube
D
Crystal plate
D
Drum motor
D
Power line
D
Water that has been treated to remove minerals .
Demineralized water
Casing
E
Electric wave generator
E
Overflow drain
E
Water level adjustment screw
E
A category of humidifiers that add moisture to the air through evaporation
Evaporative humidifier
Absorbent filter
F
Blower
F
Dry air out
F
Water pan
F
Which humidifier uses a pad consisting of numerous layers of a tight metallic mesh wetted by water delivered from above?
Fixed air filter
A humidifier solenoid valve opens, when the __ running
Furnace and blower are
Air inlet
G
Drum motor
G
Power plug
G
Drum
H
Motor control
H
Humidistat is a control device that response to
Humidity
Drain
I
Float
I
A unit with a spinning disk that flings water against a diffuser which atomizes the water on impact
Impeller humidifier
Condensate pan
J
Solenoid valve
J
Evaporator
K
Water line
K
Frost control
L
Compressor
M
Untreated water with 5 to 15 grains / gal . of mineral content .
Medium hard water
Condensor
N
Filter drier
O
Which humidifier uses a series of porous materials that wick water upward to be evaporated, by passing air
Plate
A unit with a series of spinning plastic discs with shallow grooves
Rotating disk humidifier
A unit with a water pan and rotating drum covered with an absorbent sleeve
Rotating drum humidifier
An electromechanical humidistat hydroscopic element response to a decrease in humidity by
Shrinking
Natural , untreated water ( such as rainwater ) with a low mineral content
Soft water
Water in which an ion exchange has replaced unwanted minerals with the water soluble sodium salts
Softend water
A sample of air is able to hold more moisture
The higher is dry bulb temperature
True or False ? Water treatment compounds . can be used regularly to prevent bacterial growth algae , or scale buildup in a humidifier
True
True or false air change is per hour refers to the number of times the entire volume of air in a condition spaces were placed in one hour
True
A type of central humidifier that it starts at the bottom of the duct work
Under duct humidifier
A type of humidifier that uses its own heat source to create steam
Vaporizing humidifier
Unchewed water with over 15 grain/gallons of mineral content
Very hard water
Dehumidifiers remove moisture from the air by maintaining a coil ____of the air
below the dew point
humidifier's water feed line should be tapped into a building's .
cold water line
Dehumidification may be accomplished with special chemicals called
desiccants
The ideal water to use in humidifiers to prevent both duct deposits and foreign matter from entering the airstream is
distilled water
To humidify a single room rather than an entire building, it is best to use a
portable humidifier
A ratio of the moisture content in the air compared to the maximum amount of moisture that the air can hold at its current temperature describes
relative humidity
A float switch on a dehumidifier is intended to
stop operation of the dehumidifier
A humidifier must be mounted level if the humidifier has a
water reservoir