Motor Controls 3

¡Supera tus tareas y exámenes ahora con Quizwiz!

Most DC motor contactors consist of ? set(s) of contacts.

1

What are the six steps used when troubleshooting a system

1) Define the problem 2) Decide what needs to be tested 3) Decide what type of test to perform 4) Correct the problem 5) Verify correct operation 6) Determine the cause of the failure

A single voltage DC motor has ? leads.

4

Control of the ? is used to control the speed and rotation.

Armature and Field voltage

The magnetic ? coil produces a magnetic field between the breaking contacts that forces the arc up, increasing the length of the arc and causing it to dissipate faster.

Blowout

A technology with all network devices connected to a central network media or cable identified as the backbone.

Bus

What type of flow meter depends upon the twist of the tube containing the flowing fluid to sense flow rate?

Coriolis

When analog control devices are located large distances from each other, which type of signal is preferable for installing the control wiring?

Current

Factors to not consider when installing a VFD

HP, speed, or torque

Which basic troubleshooting technique includes four levels of testing?

Information funneling

? are installed on power lines feeding VFDs to lessen the effects of harmonics generated by the VFDs.

Line reactors

Constant temperature and calorimetric sensors are types of ? flow sensors.

Mass

4 components to build a PLC-

Power Chasy Processor I/O mods

The ? limits armature current in a motor during starting and accelerating.

Rheostat Starter

A technology with all network devices connected to a network media or cable, which is connected in a loop.

Ring

A technology with all network devices connected to a common device called a hub or switch.

Star

Allen bradleys programming software includes RS Logic but not ?.

Step 7

A specification for an Ethernet® network calls for a 100BaseT system. What type of cable would be used for this network?

UTP (unshielded twisted pair)

What type of flow meter requires that particles must be present in the fluid being monitored to reflect signals back to the flow sensor?

Ultrasonic

A(n) ? flow sensor uses an object called a bluff body, which is placed in the fluid flow to produce whirlpools or eddies in the fluid flow stream.

Vortex

Motor control systems that control motor speed without feedback data for torque or speed are called ? control systems.

closed-loop

DC ? are used for analog signal control.

current and voltage

How do you troubleshoot a control valve?

induce 0-10v or 4-20ma signal into it

AC/DC, DC current-sinking, DC current-sourcing, and transistor-to-transistor logic (TTL) are the four most common types of ? circuits used in controller input modules.

input

Brushes on a DC motor should ?.

move freely

Controller input and output modules have ? between the field device power and the controller or motor drive system power to eliminate noise and operational problems.

opto-isolation

Braking resistor when using a dynamic breaking are ? with the armature.

parallel

Regenerative braking returns the regenerated power of a DC motor back to the ? .

power source

The architecture of the PC and PLC systems are similar with both featuring a motherboard, memory, expansion slots, and a(n) ? .

processor

DC drives use a ? method to smoothly accelerate and decelerate the motor.

ramping

A tachometer/generator produces a feedback voltage which is directly proportional to the ? of the motor.

speed

2 or more thermo couples.

thermopile

Speed and ? are two physical quantities that must be controlled in a motor drive.

torque

Power factor in synchronous motors have ?.

unity power factor