Sterilization and Disinfection Bb Test
after every case
Furniture and equipment should be damp-dusted with a disinfectant
Shelf life
Length of time a wrapped package remains sterile while in storage
Ionizing radiation
Method of sterilization with cobalt 60 used by manufacturers
Skin surface
On which of the following would an antiseptic be used
humidity
One factor affecting ethylene oxide sterilization is
sterilant
Packaging must allow for adequate removal of air, adequate penetration ofthe______________, and direct contact with the items.
Terminal decontamination
Process of rendering all articles free of pathogens at the end of an operative procedure
chlorine compounds
A higher concentration of __________ disinfectant agent will inactivate HIV andHep-B.
intermediate level
70-90% ethyl or isopropyl alcohol, phenolic germicidal solution such as hexachlorophene and carbolic acid, iodophor solution, and sodium hypochlorite (household bleach) are examples of which type of disinfectant?
10 hours
Activated glutaraldehyde requires total immersion of instruments for_______________ for sterilization.
lensed instruments
Activated glutaraldehyde, although not the first choice, can be used on which of the following?
Antiseptic
Agent that inhibits the growth of microorganisms on animate surfaces
Bactericidal
Agent that kills bacteria
Bacteriostatic
Agent that retards or prevents bacterial growth
coagulation of cellular protein
Autoclaving destroys microorganisms by:
red biohazard bag
Blood soaked sponges should be disposed of in a ___________________.
confined; contained
During a surgical procedure, contamination should be __________ and_________ to as small an area as possible.
packages were exposed to sterilization conditions
During steam sterilization, the heat-sensitive tape is intended to indicate that:
Ethylene oxide
Highly explosive and flammable gas used as a chemical sterilant
on their side
How must basins be positioned when sterilized in the autoclave?
covered for transport to Central Processing
If a washer-sterilizer is not adjacent to the operating room, instruments should be ___________________.
With one basin stacked inside the other and separated by a towel
If two basins are wrapped together for sterilizing, how should they be packaged?
confirm that the pack has been exposed to the sterilization process
In an autoclaved pack, an internal indicator is used to:
open
Instruments may be placed on instrument racks, stringers, or secured with towel clipsto maintain a/an _____________, fixed position when placed in sets.
expensive
Steam sterilization is preferred to other methods because it is the least ______, most efficient, and the safest method of processing heat and moisture stable items.
Autoclave
Steam sterilizer
Saturated steam
Steam that contains the maximum amount of water vapor
Vapor/Sterrad
Sterilization used primarily for endoscopes and fiberoptics
Hot air or dry heat
Sterilization used primarily for oils, petroleum products, and bulk powders
Sterilant
Substance that kills all forms of living matter including spore bearing ones
20-30 minutes
The cycle time for the Steris sterilization system is________.
bioburden
The efficacy of steam sterilization depends on lowering and limiting the ______on the items to be sterilized
Steam
The following are all examples of sterilization systems for heat sensitive items EXCEPT
biologic monitors
The only method of monitoring that assures that items are sterile and the sterilization conditions have been met is__________.
endoscopes
The peracetic acid sterilization system is a self-contained unit most commonly usedto sterilize ___________________.
Bacillus stearothermophilus
The spore-forming organism used to test the proper functioning of steam autoclaves is:
request the drill bit be resterilized
The surgeon notices debris on a drill bit at the time of use, and hands it off to be flashed. When the instrument is returned, there is no indicator in the flash pan. The surgical technologist should:
Three minutes
What is the MINIMUM time required to sterilize unwrapped metal instruments at 270 degrees F (132 degrees C)?
paper-plastic peel packs
What is the method of packaging an item that has an open end that can be closed withself-sealing adhesive or sealed with heat called?
Ethylene oxide
What method of sterilization requires a period of aeration?
penetrable by the sterilization agent
When an article is prepared for steam sterilization, the packaging materials must be
washer-sterilizer
When handling contaminated instruments after a surgical procedure, excessive bioburden should be removed by using an automated or manual method of decontamination, such as placing them into the___________ or hand washing each item.
biological indicators
Which method of monitoring uses live, nonpathogenic, spore-forming bacteria available on specially commercially-prepared strips or ampules that is placed in a test pack?
rigid containers
Which method of packaging items for sterilization is made of anodized aluminum, stainless steel, polymer, or polymer-metal combination that cannot be punctured?
250
Which of the following Fahrenheit temperatures must be reached in order to kill bacterial spores?
size of the sterilizer
Which of the following factors DO NOT affect the sterilization process?
radiating heat
Which of the following is NOT a method of sterilization?
non-porous to prevent escapage of the sterilizing agent
Which of the following is NOT a recommended characteristic for packaging materials?
moist heat
Which of the following is used with steam sterilization?
mechanical monitors
Which of the following methods of monitoring the sterilization process has devices such as thermometers, timers, pressure gauges, and recording devices?
chemical indicators
Which of the following methods of monitoring uses heat-sensitive tapes or paper strips impregnated with a chemical ink that changes color when exposed to the correct temperature and time?
sterilization
Which of the following processes destroys all microorganisms on inanimate objects including spore-bearing ones?
The by-products are water and carbon dioxide.
Which of the following statements is FALSE concerning the advantages of gas/plasma sterilization systems?
Ethylene oxide is a method of sterilization used for equipment which can withstand the extreme pressure and temperature.
Which of the following statements is a FALSE statement concerning the principles of ethylene oxide sterilization?
gravity displacement sterilizer
Which sterilizer allows steam to enter at the top of the chamber and then displaces theair downward?
pre-vacuum
Which sterilizer mechanically pulls air out of the sterilizing chamber and replaces it with steam that immediately penetrates the wrapped items
two wrappers, sequentially
Wrapping a small item with muslin or nonwoven fabric requires
Glutaraldehyde
__________________ has a broad anti-microbial range, effective against vegetative bacteria, mycobacterium tuberculosis, fungi, and viruses.
Bowie-Dick tests
____________________ are a special test performed on pre-vacuum (high vacuum) sterilizers to monitor the efficiency of the vacuum pump and the presence of air leaks and/or gases in the steam.
Ultrasonic cleaner
_____uses high-intensity sound waves to assist in the cleaning of instruments through a process called cavitation.