What button is pressed to save the displayed address and exit address mode?

*

The sounder bell connects to which terminals?

+3 , -4

2 wire smoke detectors should be tied to this terminals

-1

What 2 keys should be pressed for 3 seconds when setting a keypad address?

1 & 3

Where should the home premises be connected to on a RJ31x?

1 & 8

What zone should 2-Wire smoke detectors be on?

1 Z+/-

What size plastic grommets must a control panel have?

1/2 inch

What kind of outlet should the power supply be plugged into?

110 VAC unswitched

What is the master Code after defaulting the panel?

1234

Additional standby battery required for fire alarm installs?

12V 17.2ah

Battery charge voltage ?

13.8 VDC, max charge current 650mA

How many button zones can a vista 20p have installed?

16

How many PRM devices can be supported in an XH install?

2 max PRM devices per install

What value resistor is required for a 2 wire smoke detector?

2,000 ohm resistor

Which terminals are tip on an alarm panel?

21 & 23

Connect phone line Direct connect cable wires these terminals

21-24

Which terminals are ring on an alarm panel?

22 & 24

What is the standby battery duration required for fire installs?

24 hour

Which terminal is used for earth ground on an alarm panel?

25

What is the max number of keypads supported in a takeover?

3

What is the PIM light sequence when starting up?

3 blinks every 5 seconds

How many transmitter zones does a vista 15p support?

34

If installed, how many amp fuse should be used?

3A

What size battery fuse should be used?

3amp

Where should incoming telco be connected on a RJ31x?

4 & 5

What is the minimum battery capacity required for emergency burglary standby?

4 hours

Pim panel lead must be connected to what teminals?

4,5,6 and 7

How many transmitter zones does a vista 20p support?

48

How many wired zones can be installed on a vista 15p?

6

Non compatible Honeywell keypads will need to be replaced with which model keypads?

6160

What is the max number of zones an XH takeover can cover?

64

What resistor value should a 4 wire smoke detector use?

750 to 10,000 ohm resistor

How many wired zones can be installed on a vista 20p?

8

How many zones does the Honeywell 20P support?

8

How many wired zones can a single PRM support?

8 wired zones

How many OHM resistor is need for the external alarm sounder?

820

How long does a PIM stay in pairing mode?

90 seconds

How do you determine the total standby load on the battery?

Add 100mA to the total of AUX power output and remote keypad current

What must be done if a customer has partitions in a takeover?

Advise the customer we do not support partitions and either cancel the call or eliminate the partition.

What is a prerequisite for wires in a control panel?

All wire must be jacketed cable

What variety of smoke detectors do PRM devices support?

Both 2 and 4 wire smoke detectors

Which 4 wire smoke detector can NOT be taken over?

Brinks 2112ATL/TL

What function does the #6 do on a honeywell keypad?

Bypass

What function does the #9 do on a honeywell keypad?

Chime

What function does the #8 do on a honeywell keypad?

Code

EOLR zones should be used on this type of installation

Commercial

What are 2 approved wire connections for control panels?

Dolphin B Connectors or Wire nuts

Double balanced zone should never be installed here

Fire exits

Which two security panel models can be taken over?

Honeywell Vista 15/20P firmware version 3.0 or newer

In a panel swap installation, which model of panel is installed?

Honeywell Vista 20P

Which 3 keypads are compatible with XFINITY Home System Takeover?

Honeywell6148, Honeywell6150, Honeywell6160

Where should a PIM not be installed?

Inside the panel

What function does the #7 do on a honeywell keypad

Instant

What is the purpose of a sounder?

Makes noise in an Alarm event

What function does the #4 do on a honeywell keypad?

Max

Which NFPA code requires the condition of panel wiring to be neat and workman-like.

NFPA 70

Equipment should be installed to this standard.

NFPA 72 chapter 2

What function does the #1 do on a honeywell keypad?

Off

What is the part number for the PRM power transformer?

RE012-16

What is the part number for the PRM battery?

RE043

What function does the * do on a honeywell keypad?

Ready

What colors are the PIM panel lead colors?

Red, Black,Green, and Yellow/White

What is the National Electrical Code for a take over installation?

Sections 396 and 800 Part II

Wired contacts on a detached garage, workshop, or the like may be taken over and included on our system IF it meets this NEC code.

Sections 396, and 800 Part II

What function does the #3 do on a honeywell keypad?

Stay

If an existing system is powered down upon arrival, which 4 requirements must be met?

System must not use any RF keypads, Powering-up the system must only require the battery to be connected and transformer plugged-in, No signs of over heating with transformer, System indicators must show green" or "ready" upon powering-up

What function does the #5 do on a honeywell keypad?

Test

What supply's current to the alarm sounder?

The Battery

What label must be attached and visible on a honeywell keypad?

UL Notice

How many smoke detectors can a PRM support?

Up to 16 depending on current draw

When must fire alarm verification be disabled?

When using smoke detectors with the PRM

What type of keypad is required for a PRM install?

Zigbee

When Installing supplemental power what will be required?

a transformer and battery

This must be installed if the total power draw of the security system exceeds 600mA.

additional supplemental power

What is the typical battery life for sealed lead acid battery?

around 3 years typically

What function does the #2 do on a honeywell keypad?

away

Double balanced zone should be only used in what zones

burglary zones

What must be replaced with service date of installation written on it in a takeover?"

control panel battery

What should be connected to ECP terminals 4-7 in an alarm panel?

keypads and other addressable devices

What type of connections are not supported for system upgrades on control panels?

scotch locs

What terminal should the red wire from the PIM go to?

terminal 4

What terminal should the black wire from the PIM go to?

terminal 5

What terminal should the green wire from the PIM go to?

terminal 6

What terminal should the yellow/white wire from the PIM go to?

terminal 7

What should be done with an old control panel battery?

terminals taped and left with customer

What is the maximum distance between the power supply and control during a PRM install when #22 gauge wire is used?

up to 20 ft

What is the maximum distance between the power supply and control during a PRM install when #20 gauge wire is used?

up to 30ft

What is the maximum distance between the power supply and control during a PRM install when #18 gauge wire is used?

up to 50 ft

What firmware version is required for Honeywell Vista panels for a takeover?

v3.0 or newer

Zone doubling and double balanced zone can only be done on this panel

vista 20p

What zone should 4-Wire smoke detectors should go to?

zone 2