277 book

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

How much heat is needed to raise the temperature of 1 gallon of water 1C° at atmosphere pressure?

1 cabrie

in the US the traditional unit of measure for heat is the?

BTU

the thermocouple ____ junction is heated to create a temperature difference that generates a emf

measuring

in an automatic optical pyrometer, the filter passes radiation directly from the ___ to the ___

modulator ; detector

the filament of a manual optical pyrometer will ___ when you have adjusted it properly

disappear

the coefficient of thermal expansion is the basis for the ___ thermometer

bimetallic

an optical pyrometer senses the ____ of emitted radiation

brightness

which pyrometer can be used only for the visible light range?

narrow band

the advantage of using an optical pyrometer to calibrate high-temp thermocouple is that the optical pyrometer

does not physically touch the thermocouple

the ability of a surface to send out radiant energy is called

emissivity

when used in high temperature applications, liquid-in-glass thermometers should be

charged with nitrogen above the filling liquid

paints, crayons, and labels that change ____ can be used to determine if a process has reached a certain temperature

color

the main purpose in winding a bimetallic strip into helix is to

fit a longer strip into a small space

the proper amount of water is especially important in the use of a(n)

ice bath

which of the following are you most apt to use for calibrating temp instrument in the field?

platinum resistance thermometer

an advantage of the averaging thermometer bulb is that it

provides a rapid response to temp changes

temperature can be determined with ____ cones that soften droop as temperature increases

pyrometer or seger

pyrometer measure ____ heat, from which temperature is inferred.

radiated

an RTD measurement ____ to convert temperature changes to voltage signals

resistance

You can compensate for thermocouple reference junction temperature deviations with

resistors

advantages of RTDs include all of the following except?

self-powering capability

the ITS-90 instrument calibration standard is based on the

temperature at which substance change state

resistance thermometers and ____ indicate temperature by sensing changes in electrical resistance

thermistors

color-change indicators are dependent on both temperature and ____

time

the fix points for temperature scale calibration are the melting point, freezing point, and ____ point of certain substances.

triple

if pressure remains constant, an increase it thermal energy is required for

water to vaporize to steam

a liquid compassion bath is used to calibrate

working thermometer

the hypothetical temperature at which a substance would have no thermal energy is referred to

absolute zero

to correct the reading of a bimetallic thermometer

adjust the length of the strip

what is currently the most commonly used filling liquid in liquid-ib-glass thermometers?

alcohol

if an object at 100k radiates 100w, how much energy will it radiate if you heat it to 200k?

200w

which of the following is equivalent to 95* F in the Celsius scale

35*C

instruments certified by ___ are primary standard instrument and be used to calibrate other instrument

NIST

RTD lead wire measurement error can be overcome by?

calibrating the instrument