Ch.19 and 20
Electrical isolation
An advantage of using a transformer with a separate winding secondary is
Leads
For an inductor the induced voltage VL always BLANK the current by 90 degrees
Leads the current I by 90 degree
For an inductor, the induced voltage VL always
Mutual inductance
the ability of one coil to induce a voltage in another coil nearby is referred to as
False
The amount of inductive reactance equals two li times the frequency plus the inductance
1 uH
For the most part, inductor values below what value are not practical for use in electronic circuits
Leakage flux
For two coils with mutual inductance, any magnetic lines that do not link the two coils result in
Increases
How is mutual inductance affected when primary and secondary inductances are increased and coupling is made tighter
False
The amount of current in an ac circuit with only inductive reactance is equal to the applied voltage divided by the inductance
Apparent power
The amount of power the transformer can deliver to a resistive load is called
False
The combined parallel inductive reactance will be greater than the lowest branch reactance
True
The constant factor 2 pie indicates the circular motion from which a sine wave is derived
Infinity ohms
The dc resistance between the primary and secondary windings of a transformer should always measure
Coefficient of coupling
The fraction of total flux from one coil linking another coil is the
Inductance
The general use of BLANK is to provide minimum reactance for relatively low frequencies but more for higher frequencies
It opposes a change in current
The polarity of a coil's counter end is always such that
Opposes
The polarity of an inductor's counter end is always such that it BLANK a change in current
True
The rate of flux change is greatest when the alternating current passes through zero
Transformer
What component uses mutual inductance to step up or step down an alternating voltage
Variac
What is a common piece of test equipment used to increase the ac voltage slowly while monitoring the operation of the equipment being repaired
Eddy current
What is a current that flows in a circular path through the cross section of a transformer core that results in a loss
Impedance matching
What is it called when a transformer is used to achieve maximum transfer of power from a generator to a load when the generator and load impedances are not the same
Tight
A high value of coefficient coupling is called BLANK coupling
False
A steady dc current can induce a voltage in coil
False
An induced voltage across a coil is actually the result of inducing electrons to move in a conductor; however there is no induced current
False
In a series circuit containing two inductors and a voltage source, the current is less in the inductor with the higher inductance
Ohms
Inductive reactance is measured in
False
The base unit for inductance is the gilbert
Less than the lowest branch reactance
The combined parallel inductive reactance branch will be
Henry
The symbol for inductance is L, and the unit is the BLANK
Increases
With iron core coils the hysteresis and eddy-current losses BLANK with frequency
True
Although L can be determined when XL and f are known it's value is determined strictly by its physical construction
Wire
BLANK -wound resistors have enough inductance to be evident at ratio
Air core
BLANK coils are used in rf circuits because higher frequencies need less inductance for the required inductive effect
Inductance
BLANK is the ability of a conductor to produce voltage when the current varies
Inductive
BLANK reactance is equal to two time pi times frequency times inductance
True
Counter emf or back emf is also known as bucking voltage
1/T
Frequency is equal to
628 ohms
How much is the XL for a coil with negligible resistance that has 62.8 V across it with 0.1 A of current
True
If the number of turns of a coil is doubled in the same area and length , the inductance is increased by four times
True
In a parallel circuit with two inductors and voltage source, the voltage is the same across both inductors and is equal to the voltage source
False
Induced voltage is the result of flux cutting across an insulator
True
Inductance is the ability of a conductor to produce induced voltage when the current varies
False
Inductance is the characteristic that opposes any change in voltage
Ohms
Inductive reactance is measured in BLANK
Sine wave ac
Inductive reactance only applies to
Below
Inductor values BLANK 1 uH are generally not practical for use in electronic circuits
Mutual coupling
Mutual inductance is also called
True
One Henry is the amount of inductance that allows one volt to be induced when the current changes at the rate of one ampere per second
True
Since reactance is an opposition in ohms , the values XL in series or parallel are combined the same way as ohms of resistance
True
The higher the frequency of the alternating current and the greater the inductance the XL opposition will be increased
True
The inductive reactance is the ohms of opposition that an inductance has for sine-wave current
True
The inductive reactance of a coil is result of the inductor's counter end with a varying current
Open
The most common trouble in coils is an BLANK winding
Turns ratio
The ratio of the number of turns in the primary to the number in the secondary is the
Volt-amperes
The unit of apparent power is
Henry
The unit of mutual inductance is the
The same way as ohms of resistance
The values of XL in series or in parallel combined
False
There is inductive reactance for steady direct current
Direct
There is no inductive reactance for steady BLANK current
Laminated steel
To minimize transformer core losses while maintaining high flux density, the core can be made of
False
Too much current flowing through a coil will increase its permeability and inductance
True
Very often XL can be determined from voltage and current measurements
True
XL is measured in ohms
True
A coil had more inductance than the equivalent length of straight wire because the coil concentrates magnetic flux
Capacitance
A coil has some BLANK between windings
True
A typical air-core rf inductor is called a choke
True
Air-core for rf applications have induced values in mH and uH
True
The ability of a conductor to induce voltage in itself when current changes, is its self -inductance
Self inductance
The ability of a conductor to induce voltage in itself when the current changes is its BLANK
Equal to
The amount of current in an ac circuit with only inductive reactance is BLANK the applied voltage divided by XL
0 ohms
What is the inductive reactance for steady direct current
120 mH
What is the mutual inductance for two 400 mH could L1 and L2 that have a coefficient of coupling of 0.3
1 A
What is the primary current for a transformer with a 1:10 turns ratio that has 720 V across 7200 ohms in the secondary
Lenz
What law or theorem states that the reaction VL opposes its cause, which is the change in i?
Inductive reactance
What results from an inductor's counter end with a varying current
Alternating
When BLANK current flows in an inductance the amount of current is much less than the dc resistance alone would allow
Reflected impedance
When a transformer is used to change or transform a secondary load impedance to a new value as seen by the primary, the secondary impedance is called
The current is less than the dc resistance alone would allow
When alternating current flows in an inductance
True
When alternating current flows in an inductance, the amount of current is much less than the dc resistance alone would allow
Capacitance Inductor
When it is necessary to measure the value of an inductor, a BLANK analyzer
Higher than the primary
When the secondary of a transformer has more turns than the primary the secondary voltage is
Hysteresis loss
Which of the following is a transformer core loss
120 Hz
Which of the following is not a typical frequency rating for a power transformer
Provide electrical isolation
Which of the following is not an advantage of using an auto transformer
Block dc
Which of the following is not an example of how XL is generally used
Auto transformer
With an BLANK the secondary is not electrically isolated
Increase with frequency
With iron-core coils, the hysteresis and eddy-current losses
Is equal to the power in the primary
With zero losses assumed for the transformer the power in the secondary
6.28fL
XL equals