EPA-CORE

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

The molecule found in CFCs and HCFCs that depletes ozone is

Chlorine

How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act

$44,539

Which ASHRAE classification means slightly flammable?

A2L

Which of the following is an example of a non-condensable

Air

Which of the following has the highest Ozone Depletion Potential?

CFCs

Before shipping any used refrigerant cylinders, check that the cylinder meets what standards:

Department of Transportation

Recover any remaining refrigerant and then render the cylinder useless, then recycle the metal is the proper disposal method for

Disposable cylinders

Which type of refrigerant contains no chlorine?

HFCs

HCFCs contain

Hydrogen, Chlorine, Fluorine, and Carbon

Which international agreement (Treaty) regulated the production and use of CFCs, HCFCs, halons, methyl chloroform and carbon tetrachloride

Montreal Protocol

Which of the following refrigerant has a GWP of "1"

R-1233zd

Which of the following refrigerants is an HFO

R-1234ze

What are refrigeration and air-conditioning compressor heaters used for

To reduce the amount of refrigerant in the oil

HFCs

will not damage stratospheric ozone, but have a high GWP

The condenser

changes a high-pressure vapor to a high-pressure liquid

A refrigerant cylinder designed to hold recovered refrigerant has a

grey body and yellow top.

The low-side test-pressure data-plate value should be used by a technician to determine a safe pressure for:

leak testing

A high-pressure appliance containing 210 lbs. of R-407C refrigerant must be evacuated (recovered) to a level of

10 inches of vacuum

The rupture disk on a low-pressure chiller has a burst pressure of

10 psig

A comfort cooling system that contains 50 pounds or more of R-410A is leaking. What will be the new maximum allowable annual leak rate starting in 2019

10%

A single chlorine atom can destroy how many ozone molecules

100,000

Reusable refrigerant containers under high-pressure must be hydrostatically tested how often

5 years

The EPA's leak repair requirements apply to appliances with a charge size of

50 pounds or greater.

When charging a chiller, refrigerant vapor is introduced into the system before charging with liquid. This is because

Liquid charged into a deep vacuum will cause the refrigerant to boil and may lower temperatures enough to freeze the water in the tubes.

If a reclamation facility receives a tank of mixed refrigerant, they may:

refuse to accept the refrigerant or charge extra for processing it.

The use and release of CFCs and HCFCs has a far reaching effect on

the stratosphere

An ozone molecule contains

three oxygen atoms

To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis defines

Reclaiming

Clean refrigerant for reuse by separating the oil from the refrigerant and removing moisture from the refrigerant by passing it through one or more filter driers, is the definition of

Recycle

Which refrigerants can be mixed in an appliance

Refrigerants cannot be mixed

Silicone elastomers, for use in seals and gaskets, are not compatible with which refrigerants

HFOs

The chlorine in CFCs and HCFCs:

will not dissolve in water.

When is it essential to take measures to help release trapped CFC, HCFC, or HFC refrigerant from the compressor oil during refrigerant recover

When using passive recovery devices on small appliances with non-operating compressors.

Before shipping any used refrigerant cylinders, what standards should be checked

Department of Transportation The Significant New Alternatives Policy (SNAP) Underwriters Laboratories *All of the above*

Crop loss, eye disease and skin cancer have been attributed to:

Depletion of Stratospheric ozone

What is the Significant New Alternatives Policy (SNAP) Program?

EPA's program that identifies refrigerants with lower overall risks to human health and the environment.

Which of the following refrigerant has a GWP closest to "1"

R-1233zd

The compressor

changes a low-pressure vapor to a high-pressure vapor


Kaugnay na mga set ng pag-aaral

6.3 endochondral and intramembranous ossification

View Set

Nitro-Lift Technologies, L.L.C. v. Howard

View Set

pharm prepu 41 diabetes mellitus

View Set

Chapter 2, Squares and Square-roots

View Set

BADM 324 Exam 1 Homework Question Answer Guide

View Set

Mental Health - Prep U - Chapter 24

View Set