Fundamentals of CT
List five components of the CT imaging system.
1) Gantry 2) X-ray Tube 3) Generator 4) Detectors 5) Filters 6) Scanning console/computer 7) Table 8) Slip rings 9) Collimators 10) Detector arrays
Dual Source CT scanner includes one x-ray tube
False
6th generation CT scanners has a rotating array of detectors that allowed a helical/spiral scanner
True
Array processors 1) read converted data from detectors 2) reconstruct raw data into cross-sectional images 3) measure radiation dose of patients a) 1 and 2 only b) 1 and 3 only c) 2 and 3 only d) 1, 2 and 3
a) 1 and 2 only
How many degrees of indexing was the 1st generation CT scanner able to use. a) 1º b) 30º c) 180º d) 360º
a) 1º
Fourth generation scanners employed detectors that were: a) Curved/nonrotating b) Linear/rotating c) Curved/rotating d) Linear/nonrotating
a) Curved/nonrotating
Which of the following types of scanners used water bags? a) First generation only b) First and second generation c) First, second and third generation d) Water bags have never been used with CT scanning.
a) First generation only
First generation scanners were only capable of imaging the: a) Head/brain b) Extremities c) Chest, abdomen and pelvis. d) A and B are correct.
a) Head/brain
Which of the following is the most effective type of CT detector? a) Scintillation b) Xenon gas c) Linear array d) Photodiode
a) Scintillation
Nutating refers to the process of: a) Tilting the detector ring b) Tilting the x-ray tube c) Tilting the gantry d) Translation
a) Tilting the detector ring
Which type of beam did 4th generation CT scanners utilize? a) fan beam b) cone beam c) pencil beam d) electron beam
a) cone beam
Which type of beam did 2nd generation CT scanners utilize? a) fan beam b) cone beam c) pencil beam d) electron beam
a) fan beam
How many detectors did the 1st generation CT scanner include? a) 1 detector b) 2 detectors c) stationary multidetectors d) curved array of detectors
b) 2 detectors
How many degrees of indexing was the 2nd generation CT scanner able to use. a) 1º b) 30º c) 180º d) 360º
b) 30º
Second generation scanning employed: a) Pencil beam/a single detector b) A fan beam/multidetectors c) More indexing (compared with first generation scanners) d) B and C are correct
b) A fan beam/multidetectors
Which of the following sources of radiation were used in Hounsfield's first primitive CT scanner? a) X-ray b) Americium c) Radium d) Radon
b) Americium
Beam-shaping filters are designed to: a) Remove higher-energy photons from the beam b) Change the spatial distribution of the beam c) Decrease subject contrast d) Restrict the path of photons coming from the x-ray tube
b) Change the spatial distribution of the beam
Which of the following x-ray beam geometries is used by modern, multidetector CT scanners? a) Pencil beam b) Cone beam c) Fan beam d) Pinpoint beam
b) Cone beam
First generation CT scanners used _____ beam scanning. a) Cone b) Pencil c) Fan d) Pinpoint
b) Pencil
Which generation of CT scanners was the first to use a curved array of rotating detectors? a) Second b) Third c) Fourth d) Fifth
b) Third
Fifth generation CT scanners were specialized for what specific scan? a) cholonagraphy b) cardiac imaging c) brain imaging
b) cardiac imaging
Which type of beam did 3rd generation CT scanners utilize? a) fan beam b) cone beam c) pencil beam d) electron beam
b) cone beam
Which type of beam did 7th generation CT scanners utilize? a) fan beam b) cone beam c) pencil beam d) electron beam
b) cone beam
CT scanner x-ray tube voltages range from ______ to _____ kilovolts (kV). a) 60; 100 b) 80; 120 c) 80; 140 d) 100; 160
c) 80; 140
A CT gantry includes all of the following components except: a) Collimators b) Detectors c) Central processing unit d) Bow tie filters
c) Central processing unit
Which generation of CT scanners is associated with the term "EBCT" and the use of an electron beam gun? a) Seventh b) Sixth c) Fifth d) Fourth
c) Fifth
Generators are often times located within the gantry. These types of generators are typically: a) Full wave/three-phase b) Medium frequency c) High frequency d) Multiwave/two-phase
c) High frequency
How many detectors did the 4th generation CT scanner include? a) 1 detector b) 2 detectors c) stationary array of detectors d) curved array of detectors
c) Stationary array of detectors
In sixth generation CT scanners, which of the following elements rotate around the patient? a) The x-ray tube b) Detectors c) X-ray tube and detectors d) No choices are correct
c) X-ray tube and detectors
How many detectors did the 7th generation CT scanner include? a) 1 detector b) 2 detectors c) multiple rows/multisection d) curved array of detectors
c) multiple rows/multisection
Which type of beam did 1st generation CT scanners utilize? a) fan beam b) cone beam c) pencil beam d) electron beam
c) pencil beam
How many detectors did the 2nd generation CT scanner include? a) 1 detector b) 2 detectors c) stationary multidetectors d) curved array of detectors
c) stationary multidetectors
How many degrees of indexing was the 3rd generation CT scanner able to use. a) 1º b) 30º c) 180º d) 360º
d) 360º
The term "translation" is associated with _____ generation scanners. a) First b) Second c) Third d) A and B are correct
d) A and B are correct
Beam-shaping filters are generally composed of: a) Aluminum b) Copper c) Teflon d) A and C are correct
d) A and C are correct
Which of the following terms is associated with seventh generation spiral-helical technology? a) Multisection scanner b) Multidetector scanner c) Multiple detector array scanner d) All choices are correct
d) All choices are correct
Spiral-helical CT scanning is based on: a) Sequential data acquisition. b) Slip-ring technology. c) Volume data acquisition. d) B and C are correct
d) B and C are correct
The process related to the first computed tomography scanner was called: a) Computer-assisted tomography b) Reconstructive tomography c) Hounsfield tomography d) Computerized transverse axial scanning
d) Computerized transverse axial scanning
When image data is acquired by a CT scanner, it goes through a process known as: a) Convolution b) Photon flux c) Digitization d) Quantization
d) Quantization
All power to the gantry of a spiral-helical CT scanner is conveyed via: a) High-tension cables b) Rotating wire brushes c) Photon flux d) Slip rings
d) Slip rings
In multislice CT scanners, detector systems with equal-size detector elements are called _____ arrays. a) Linear b) Curved c) Adaptive d) Symmetric
d) Symmetric
How many detectors did the 3rd generation CT scanner include? a) 1 detector b) 2 detectors c) stationary multidetectors d) curved array of detectors
d) curved array of detectors
Which type of beam did 5th generation CT scanners utilize? a) fan beam b) cone beam c) pencil beam d) electron beam
d) electron beam
First generation CT scanners were made to scan which specific part of the body? a) chest b) extremities c) abdomen d) head
d) head
Data Acquisition System (DAS) are in charge of: a) Amplify and digitize the date before it reaches the computer b) encodes measurements into binary data c) measures radiation d) transmits binary data to computer e) all of the above
e) all of the above