IFSTA 6th Edition Chapter 17: Fire Control

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

Protective clothing used for ground cover fires should meet the requirements for NFPA¨: A.1001. B.1205. C.1799. D.1977.

1977 p.1054

Firefighters and the public should stay at least ___ from underground transmission lines during a fire. A.100 feet (30 m) B.200 feet (60 m) C.300 feet (91 m) D.400 feet (120 m)

300 feet (91 m) p.1033

Which of the following may provide firefighters the BEST access to a basement fire? A.A window well B.An above-ground window C.An interior open stairwell D.An interior enclosed stairwell

A window well p.1019

If a vehicle using ethanol or methanol is on fire, use only ___ to extinguish. A.water B.Class D fire extinguishers C.aqueous film forming foam D.Alcohol Resistant Class B foam

Alcohol Resistant Class B foam p.1046

Nozzle selection is based upon which of the following factors? A.Size of building B.Stream reach needed C.Available water supply D.Ease of hoseline deployment

Available water supply p.1009

How should a Class D fire be extinguished? A.By dousing it with water B.By directing hose streams onto it C.By using dry chemical extinguishers D.By shoveling Class D extinguishing agents onto it

By shoveling Class D extinguishing agents onto it p.1037

Which of the following techniques are the MOST essential part of any ground cover operation? A.Lookouts B.Safety zones C.Escape routes D.Communications

Communications p.1056

Which of the following is one of the FIRST priorities at a fire in a protected structure? A.Shutting a control valve B.Deploying a master stream C.Stopping the flow from a sprinkler D.Connecting to a fire department connection (FDC)

Connecting to a fire department connection (FDC) p.1027

Which of the following is used to shut down the water supply to the entire fire protection system? A.FDC B.Control valve C.Sprinkler head D.Sprinkler system

Control valve p.1027

Which strategy is typically selected when property is not salvageable? A.Direct B.Indirect C.Offensive D.Defensive

Defensive p.1006

Which of the following is a guideline for vehicle fire attacks? A.Rescue vehicle occupants first B.Position hoseline behind exposures C.Attack the fire from a 90-degree angle D.Deploy hoseline that will provide a minimum of 95 gpm (360 L/min)

Deploy hoseline that will provide a minimum of 95 gpm (360 L/min) p.1039

In which type of fire attack is water applied directly onto burning fuels until the fire is extinguished? A.Gas cooling B.Direct attack C.Indirect attack D.Combination attack

Direct attack p.1013

Which method for attacking ground cover fires is action taken against flames at its edge or closely parallel to it? A.Direct attack B.Indirect attack C.Offensive attack D.Defensive attack

Direct attack p.1054

Which of the following should be done once the fire has been controlled? A.Remove air bags B.Remove fuel tanks C.Disconnect the battery D.Disconnect automatic locks and windows

Disconnect the battery p.1042

At fires in electrical transformers, which type of extinguisher should be used? A.Water B.Class A foam C.CO2 extinguisher D.Dry chemical extinguisher

Dry chemical extinguisher p.1033

Which of the following is the primary location for shutting off power? A.Power line B.Transformer C.Electric meter D.Electrical panel

Electric meter p.1023

Which nonfire hazard may be found around military training areas? A.Explosives B.Animal traps C.Unstable trees D.Rolling or falling debris

Explosives p.1057

Which of the following is a long narrow strip of fire extending from the main fire? A.Head B.Flank C.Island D.Finger

Finger p.1052

Which of the following statements regarding burning characteristics of ground cover fires is MOST accurate? A.Heavy fuels burn faster than lighter fuels. B.Fires spread faster when fuels are close together. C.Fuels that contain more moisture burn with greater intensity D.Loosely piled fuels burn slower than those that are tightly compacted.

Fires spread faster when fuels are close together p.1051

Which of the following slows the transfer of heat to other combustibles and reduces the chances of overhead gases igniting? A.Gas cooling B.Direct attack C.Indirect attack D.Combination attack

Gas cooling p.1015

Which of the following is the area of unburned fuel next to the involved area? A.Spot B.Green C.Finger D.Perimeter

Green p.1053

Which kind of ground cover fire is slow moving and smoldering? A.Crown fire B.Ladder fire C.Ground fire D.Surface fire

Ground fire p.1050

If a fire is ventilation controlled, what will happen if a door is opened? A.Fire will self-extinguish B.Overhead gas layers will cool C.Heat release rate will significantly increase D.Added oxygen will decrease fire development

Heat release rate will significantly increase p.1012

Which of the following is the side of the fire opposite the head? A.Heel B.Black C.Origin D.Green

Heel p.1053

Who makes the decision to make entry? A.Safety officer B.Incident commander C.First-arriving firefighter D.Rapid intervention crew

Incident commander p.1011

Which type of fire attack is made through a window or other opening, directing the stream toward the ceiling to cool the room? A.Gas cooling B.Direct attack C.Indirect attack D.Combination attack

Indirect attack p.1014

Which method for attacking ground cover fires is used at varying distances from the advancing fire? A.Direct attack B.Indirect attack C.Offensive attack D.Defensive attack

Indirect attack p.1054

Which topography features may alter air flow and cause turbulence? A.Aspect B.Chutes C.Drainages D.Local terrain

Local terrain p.1052

In fires in the upper levels of structures, which of the following determines the method of fire attack? A.Available hoselines B.Available personnel C.Location of the stairway D.Location of the standpipe

Location of the standpipe p.1016

Which of the following guidelines should be used when switching strategies? A.Turn off radios in order to maintain radio silence B.Abandon hoselines when strategy change is made C.Split away from team in order to cover more ground D.Maintain situational awareness to recognize changes in fire behavior

Maintain situational awareness to recognize changes in fire behavior p.1007

In passenger compartment fires, what nozzle pattern should be used through a broken window? A.Narrow fog pattern B.Medium fog pattern C.Direct stream pattern D.Direct straight stream pattern

Medium fog pattern p.1042

Which strategic transition may be necessary when the situation rapidly changes? A.Indirect to direct B.Direct to indirect C.Offensive to defensive D.Defensive to offensive

Offensive to defensive p.1007

Which of the following is one of the ten standard fire fighting orders? A.Post lookouts when there is possible danger B.Treat all incidents like a hazardous materials incident C.Wear standard firefighting structure gear at all incidents D.Fight fire passively, providing for exposure protection first

Post lookouts when there is possible danger p.1056

Hoseline selection should be based on which of the following factors? A.Potential fire spread B.Location of exposures C.Water pressure available D.Number of available apparatus

Potential fire spread p.1008-1009

What should be done for a fire involving a hydrogen-fueled vehicle? A.Extinguish the fire immediately B.Request hazardous materials team C.Cut A, B, and C posts for easiest extrication D.Protect exposures and allow fuel to burn off

Protect exposures and allow fuel to burn off p.1046

Which of the following is required for firefighters participating in ground cover fire fighting? A.Web belt B.Bunker gear C.Nomex hood D.Protective footwear

Protective footwear p.1054

Which of the following pre-entry considerations is critical to firefighter safety and effectiveness? A.Identifying exposures B.Ensuring adequate water flow C.Reading fire behavior indicators D.Evaluating available forcible entry tools

Reading fire behavior indicators p.1012

Which alternative energy source will include a shutoff switch on the electric meter? A.Solar panels B.Hydrogen cells C.Nuclear power rods D.Fuel-powered generators

Solar panels p.1024

What fire streams are most effective at fires involving small unattached structures? A.Fog streams B.Master streams C.Narrow streams D.Straight streams

Straight streams p.1047

Which kind of ground cover fire burns on the soil surface, consuming low-lying grass, shrubs, and other vegetation? A.Crown fire B.Ladder fire C.Ground fire D.Surface fire

Surface fire p.1050

Which kind of fuels include grass, field crops, and downed limbs? A.Aerial fuels B.Ladder fuels C.Surface fuels D.Subsurface fuels

Surface fuels p.1051

Which of the following statements regarding ground cover fires is MOST accurate? A.They are very slow moving. B.They are usually very small in size. C.They are always caused by natural events. D.Their characteristics are very different from fires in burning buildings.

Their characteristics are very different from fires in burning buildings p.1049

Which of the following statements regarding commercial basements and subfloors is MOST accurate? A.They are only comprised of steel girders B.They are usually less robust than residential basements C.Those made of metal floor supports have little chance of failure D.They may have similar construction to those in residential structures

They are usually less robust than residential basements p.1020

How may elevators be used at fires in upper levels of structures? A.To transport equipment to the fire floor B.To transport personnel to the staging area C.To transport empty SCBA to the staging area D.To transport firefighting tools to the fire floor

To transport personnel to the staging area p.1016-1017

Which of the following should be determined during vehicle incident size-up? A.Type of fuel B.If engine is still running C.Vehicle make and model D.Number of victims and their ages

Type of fuel p.1039

What tactics should be used at incidents involving liquefied petroleum gas vehicles? A.Extinguish fire immediately B.Approach from a 90-degree angle C.Use gas detectors to determine leaks D.Direct fire streams at bottom of LPG tank

Use gas detectors to determine leaks p.1044

Which of the following is a guideline for electrical emergencies? A.Cut power lines upon arrival B.Move any vehicles that are in contact with electrical wires C.Stay at least 20 feet (6 m) from power lines when raising ladders D.Use lockout/tagout devices when working on electrical equipment

Use lockout/tagout devices when working on electrical equipment p.1036

Which of the following may be used as interior exposure protection? A.Proper use of forced ventilation B.Use of fire-rated walls and doors C.Applying water spray between fire and exposure D.Opening doors between fire area and unaffected area

Use of fire-rated walls and doors p.1021

Which of the following is a visual indicator of an alternative fuel vehicle? A.Vehicle size B.Vehicle year C.Vehicle color D.Vehicle profile

Vehicle profile p.1042

Which of the following should be used to ensure that floor assemblies over basement fires are safe for personnel to work? A.Thermal imager B.Sounding of the floor C.Visual inspection of floor joist D.Temperature check of floor joists

Visual inspection of floor joist p.1019

Which type of control valve extends horizontally through the wall with a target and valve operating nut on the outside of building? A.Post indicator valve B.Outside stem and yoke C.Wall post indicator valve D.Post indicator valve assembly

Wall post indicator valve p.1028

What should be done if smoke is visible at an electrical vehicle incident? A.Chock wheels B.Secure vehicle C.Turn off ignition D.Wear full PPE and SCBA

Wear full PPE and SCBA p.1045

Which of the following is an influence on ground cover fires? A.Weather B.Size of fire C.Cause of fire D.Ignition sources

Weather p.1049

A master stream device should enter a structure: A.in a straight line. B.at an upward angle. C.in a circular pattern. D.at a downward angle.

at an upward angle p.1029

Class D fires involve: A.combustible metals. B.transportation vehicles. C.stacked and piled materials. D.energized electrical equipment.

combustible metals p.1037

Class C fires are those involving: A.combustible metals. B.transportation vehicles. C.stacked and piled materials. D.energized electrical equipment.

energized electrical equipment p.1031

At fires involving stacked and piled materials, fire streams should be directed at the: A.middle of the fire. B.extreme edge of the fire. C.exposures surrounding the fire. D.ground, deflecting up onto the fire.

extreme edge of the fire p.1047

At fires at commercial high-voltage installations, the entry team must wear: A.full PPE, including SCBA. B.vapor protective clothing. C.wildland firefighting clothing. D.chemical protective clothing.

full PPE, including SCBA p.1034

If a firefighter is inside the gradient field of a grounded power line or feels a tingling in the legs, they should ___ away from the area. A.run B.hop C.walk D.crawl

hop p.1037

Liquefied petroleum gas is stored: A.as a solid. B.in a gaseous form. C.in a liquid state under pressure. D.in its purest form as butane gas.

in a liquid state under pressure p.1026

Fuel tanks on a natural gas vehicle are often located: A.under the hood. B.in the trunk area. C.under the vehicle. D.behind the rear tires.

in the trunk area p.1043

In its pure form, natural gas is: A.butane. B.ethanol. C.propane. D.methane.

methane p.1025

The deployment of a master stream device requires a minimum of: A.one firefighter. B.two firefighters. C.three firefighters. D.four firefighters.

two firefighters p.1030

The shutoff valves for water are located: A.underground. B.inside the house. C.at the water department. D.near the electrical meter.

underground p.1026

If a ground cover fire starts near transmission lines: A.extinguish the fire immediately. B.wait for the fire to self-extinguish. C.extinguish the fire using only Class A foam. D.wait for the fire to burn away from the point of contact.

wait for the fire to burn away from the point of contact p.1032


Kaugnay na mga set ng pag-aaral

Mastering Biology Questions (Chapter 3)

View Set

Chapter 2: The project management and information technology context

View Set

chapter 22 mylab & quiz questions

View Set

Gel Electrophoresis, Gel Electrophoresis

View Set

Nutrition Chapter 11: The Fat-Soluble Vitamins: A, D, E, and K

View Set