Procedures - Chapter 1, Part E - Digital Imaging

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

Radiographic contrast in the digital image is primarily affected by: A) kV B) signal to noise ration C) application of processing algorithms D) matrix size

C

The current range of spatial resolution for digital radiographic imaging systems is between: A) 1.0 - 2.0 lp/mm B) 10 - 50 lp/mm C) 0.5 - 1.0 lp/mm D) 2.5 - 5.0 lp/mm

D

___ is the application of specific image processing that alters the pixel values across the image so as to present a more uniform image appearance.

Equalization

What three factors affect distortion in digital imaging?

SID, OID, CR alignment

Which of the two pixel sizes is most critical in maintaining high resolution digital images?

acquisition

List the terms describing the two pixel sizes used in digital imaging.

acquisition pixel size, display pixel size

Digital processing involves the systematic application of highly complex mathematical formulas called ___.

algorithms

Highly complex mathematical formulas used in creating the digital image are termed:

algorithms

Post-processing that adds text to images.

annotation

which one of the following factors will result in an increase in noise? A) excessive mAs B) scatter radiation C) high kV D) decrease in pixel size

b

In digital imaging, the term ___ replaces density as applied in analog-based imaging.

brightness

In post-processing, window level controls the ___ of the digital image

brightness

The intensity of light that represents the individual pixels in the image on the monitor is termed:

brightness

List the six image quality factors to evaluate digital images.

brightness, contrast resolution, spatial resolution, distortion, exposure indicator, noise

In post-processing, window width controls the ___ of the digital image

contrast

The difference in brightness between light and dark areas of an image is known as ___.

contrast

A digital imaging system's ability to distinguish between similar tissues is ___.

contrast resolution

The greater the bit depth of a digital system, the greater the:

contrast resolution

The range or level of image contrast in the digital image is primarily controlled by ___.

digital processing

In addition to acquisition pixel size, spatial resolution in the digital image is controlled by ___.

display matrix

What is the minimum pixel size that can be displayed by a monitor?

display pixel size

The misrepresentation of object size or shape as projected onto radiographic recording media is ___.

distortion

Exposure latitude is also known as ___.

dynamic range

Post-processing that increases brightness along the margins of structure to increase visibility of the edges.

edge enhancement

A numeric value that is representative of the exposure the digital image receptor receives is termed the ___.

exposure indicator

Dynamic range is also known as ___.

exposure latitude

T/F: Brightness cannot be altered in the digital image once it has been processed.

false

T/F: Changes in kV have little impact on patient dose with digital imaging

false

T/F: Digital imaging requires that images be chemically processed.

false

T/F: Digital imaging systems have a narrow dynamic range

false

T/F: Focal spot size has no impact on the resolution of the digital images?

false

T/F: OID and SID have little impact on spatial resolution of the digital image.

false

T/F: The factors that affect image distortion for the digital image are different from those that affect film-screen systems.

false

T/F: a high SNR results when an insufficient mAs is used in creating a digital image.

false

T/F: postprocessing can correct for a low SNR image

false

The smaller the acquisition pixel size, the ___ (lesser/greater) the spatial resolution.

greater

A ___ (high/low) SNR is desirable in digital imaging.

high

Post-processing that reverses the light and dark pixel values of an image.

image reversal

Verifying the exposure indicator for each exposure is essential in producing quality digital images with the ___.

least possible dose to the patient

What does lp/mm mean?

line pairs per millimeter

When insufficient mAs is applied in the production of a digital image, it produces a ___ (high or low) SNR image

low

What causes a low SNR?

low mAs

What is the primary factor for SNR?

mAs

List the four factors that affect the exposure indicator in the digital image.

mAs, kV, total IR area irradiated, objects exposed

Post-processing that enlarges all or part of an image.

magnification

Each digital image is two-dimensional and is formed by a ___ of picture elements called pixels.

matrix

Another term for image noise is ___.

mottle

A random disturbance that obscures or reduces clarity is ___.

noise

The ___ of the image depends on the display capabilities of the monitor.

perceived resolution

Each digital image is formed by two-dimensional elements termed:

pixels

Changing or enhancing the electronic image to improve its diagnostic quality is called ___.

post-processing

The primary controlling factor of contrast in the digital image is:

processing algorithms

SNR is the acronym for ___.

signal to noise ratio

Post-processing that applies specific image processing to reduce the display of noise in an image.

smoothing

A radiographic image that is viewed on a computer monitor is known as a ___.

soft copy

The recorded sharpness or detail of structures on the image is known as ___.

spatial resolution

Post-processing that removes background anatomy to allow visualization of contrast media-filled structures.

subtraction

T/F: A wide exposure latitude associated with digital imaging systems will reduce repeat exposures.

true

T/F: Changes in mAs do not have a primary controlling effect on digital image brightness.

true

T/F: Digital images are a numeric representation of the x-ray intensities that are transmitted through the patient.

true

T/F: kV and mAs do not have the same direct effect on image quality with digital imaging as they do with IR-screen imaging.

true

T/F: the current range of spatial resolution for digital general radiographic imaging is between 2.5 - 5 line pairs per MM.

true

Exposure latitude with digital imaging is more ___ (narrow/wide) when compared with analog imaging.

wide


Kaugnay na mga set ng pag-aaral

ATI Book - Med Surg 2 Chapter 76 - 83

View Set

Chapter 27: Disorders of Cardiac Function, and Heart Failure and Circulatory Shock

View Set

SCMA 331 Exam 3 (Chapters 11-16)

View Set

Sleep, wound care, ethics and legal EAQ

View Set