Hazardous Material Report Considered CAT 1 safety discrepancies. Must be submitted with 24 hours.

HMR

Tools Signed WUC Trans Action Taken Corrective Action

How do you validate a MAF prior to signing it off?

7 Beginning of shift Checking out tools Beginning of job Mid job End of job Checking tools in End of shift

How many times should you be checking tools?

PQDR or Y Code

If you have a defective part, what do you do?

TD's Serno Match Defects RFI Tag

When screening and receiving parts, what are you looking for?

Never

When will you ever CDI your own work?

NAMP Ch. 10

Where can i find NAMPSOP

Appendix E

Where can i find information on MAF documentation?

11 - O

Which trans code and action taken would you use for corrosion prevention?

11 - Z

Which trans code and action taken would you use for corrosion treatment?

Not involving removal of defective component / repair

11 - C

Non repairable components documented as failed parts. Repair or replacement.

12 - B

Removal of non-defective component

16 - P

Installation of non defective component

17 - Q

Remove and replace of defective repairable components

23 - R

Aircraft Confined Space Program Vibration Analysis Maintenance Department Safety SE Misuse and Abuse Name Compliance Auditing Technical Data Management NAMDRP

7 Programs QA Manages

Acceptance Inspection Deficiency Report. Will be submitted for all newly received, manufacture, or reworked aircraft.

AIDR

QA

As a CDI who do you work for?

Baseline Trouble Report. Will be submitted for baseline deficiencies that prevent the issuance of work orders for inspections, TD's or unscheduled maintenance against aircraft or tracked components.

BTR

Wrong Work Unit Code to CAGE or Part Number Relationship. Items with no WUC. Incorrect removal intervals for a life limited component. TD's received by the activity and not in the baseline. Incorrect inspection intervals for an aircraft or tracked component.

Baseline Deficiencies include

28 Days

When does corrosion and bare metal become a downing discrepancy?

Administrative

During a special or conditional inspection, what type of MAF would you cut?

Malfunction or failure of a component, which if not corrected, could result in death or injury to personnel, or damage to or loss of aircraft, equipment, or facilities. A design flaw that allows incorrect installation of parts resulting in possible system malfunction or failure. In-flight or group loss.

Examples Of HMR

When specific WUC can't be chosen

Generic WUC

Joint Deficiency Reporting System. Website used for submitting all NAMDRP DR's.

JDRA

QA Matrix School Tracker Hi Times Item's in cal PC's (CDI's, CDQ's, QAR's) Program Managers

Name some things you can find in the MMP

Product Quality Deficiency Report. Submitted for deficiencies in new or newly reworked material, products, and software. CAT 1 & CAT 2.

PQDR

Will be submitted for quality deficiencies with the potential to cause death, injury, or severe illness. Must be submitted within 24 hours.

PQDR CAT 1

Will be submitted for quality deficiencies that do not affect safety or impair combat efficiency. Must be submitted within 5 calendar days.

PQDR CAT 2

Non-safety related technical publication deficiencies that cause maintenance delays of less than 8 hours.

TDPR CAT 3

Non-safety related technical publication deficiencies that does not cause maintenance delays.

TDPR CAT 4

Technical Publication Deficiency Report. Submitted to correct deficiencies in technical publications. Include MRC, Checklist, WUC manuals, shop process cards, MIM, IETMs, weapons manual, weapons checklist, reliability cards, IPB, and TB. CAT 1, CAT2, CAT 3, & CAT 4.

TPDR

Will be submitted on safety related technical publication deficiencies that could result in death or injury to personnel, or damage to or loss of aircraft, equipment, or facilities.

TPDR CAT 1

Non-safety related technical publication deficiencies that cause maintenance delays of 8 hours or more.

TPDR CAT 2

Interim Rapid Action Change.

What are IRAC's?

Info left for the next worker if the job can't be completed

What are In-Process inspections?

Naval Aviation Maintenance Program Standard Operating Procedures Chapter 10

What are NAMSOP's? Where can i find them?

Technical Directive

What are TD's?

Screening IP Final

What are the inspection types?

CDI Designation

What does the 4790/12 state?

Establishing requirements for reporting material deficiencies, poor workmanship, and improper procedures in the technical pubs

What is NAMDRP for?

Structural Repair Card AZ's Logbook

What is a SRC? Where does it go?

Mission Essential Subsystem Matrix

What is the MESM

MRC-000-insp.rea.index

What is the MRC QAR Matrix?

MRC's / Pre ops Hazmat, Tools, Hour Requirements, Corrosion Prone Areas, Sequence Control

What is the PMIC? Where can i find it in?

Indicates where QA is annotated in pubs and classifies if a CDI or a CDQ of QA is required. MMP

What is the QA Matrix? Where can i find it?

FOM - Remove something to get somewhere Assist - Assist with help

What is the difference between a FOM and a assist MAF?

Conditional - caused by events such as a lightning strike or a freshwater Special - By hours such as a 25 hour, 50 hour, 100 hour, 182 Day, and a 56 Day

What is the difference between conditional and special inspection?

No Defect / if you didn't touch it

When can i use A 799?


Ensembles d'études connexes

Chemistry Study Guide Midterm Exam

View Set

Porth's Essentials of Pathophysiology Chapter 18

View Set

Excel - Chapter 1 - Creating a Worksheet and Charting Data

View Set

Troubleshooting High-Speed Data Service

View Set

Integumentary, Burns (36, 50, 51)

View Set

22. Primary and Secondary Markets and Financing NEW

View Set