What do we do if the white slide armed indicator light is illuminated?

Close the door and disarm the door before trying to open again

What do we do if the red cabin pressure indicator light is flashing?

Close the door and report to the flight deck

Where can cabin lighting be controlled?

In the FAP (Forward Attentant Panel) and AAP (Aft Attentant Panel)

What light means flight deck emergency call on the ACP?

Red flashing light

What is the Flight Deck warning for lavatory smoke detection? (3)

1. A repetetive chime 2. A red master warning light 3. A smoke warning indicator on the ECAM

What is the flight deck entry procedure in EMERGENCY situation? (5)

1. CCM enters emergency access code + # 2. Buzzer will sound continuously and OPEN light flashes in flight deck 3. Keypad green light flashes 4. After a preselected time (30 sec), the keypad green light comes on steady indicating the door is unlocked for 5 seconds (if no action is taken by the flight crew) 5. Cabin crew can push the door open

What is the flight deck entry procedure in NORMAL situation? (3)

1. CCM enters normal access code (1+#) 2. Flight crew check video surveillance and, when safe to do, they will unlock the door 3. Green light indicates that the door has been unlocked for 5 seconds

Opening Type C emergency exit in EMERGENCY situation on LAND: (6)

1. Check outside conditions 2. Check door is in slide ARMED mode 3. Grasp assist handle and hold on to it 4. Lift door control handle rapidly up and release it 5. Door opens automatically and locks in fully open position 6. Pull manual inflation handle to ensure slide inflation

Opening Type I cabin door in an EMERGENCY situation: (6)

1. Check outside conditions 2. Check the door is in slide ARMED mode 3. Grasp assist handle and hold on to it 4. Lift door control handle rapidly up and release it 5. Door opens automatically and locks in the fully open position 6. Pull the manual inflation handle to ensure slide/slideraft inflation

Opening Type I cabin doors in NORMAL situation: (5)

1. Check outside conditions 2. Make sure the slide arming lever is in disarmed position and the safety pin is installed 3. Make sure the cabin pressure warning indicator is not illuminated and flashing 4. Grasp one of the assist handles (on the fuselage) and lift the door control handle fully up 5. Push the door outwards and forward by using the door assist handle until door locks in fully open position

Opening Type C emergency exit in EMERGENCY situation on WATER: (4)

1. Check outside conditions 2. Place door in slide DISARMED mode 3. Grasp assist handle and hold on to it 4. Lift door control handle up and push door outwards and forward until it locks against the fuselage

Opening Type III emergency exit from inside: (Only opened in emergency situations) (9)

1. Check outside conditions 2. Remove the handle cover by opening the cover flap recess 3. Hold on to the handle recess 4. Lift the transparent handle flap (if installed) 5. Pull down the hatch handle 6. Lift the hatch into the cabin, away from the frame, by using the handle recess and the cover flap recess 7. Throw out the hatch through the opening 8. The slide inflates automatically 9. Pull the manual inflation handle

What is the priority order of interphone calls? (4)

1. Emergency 2. Flight deck 3. Conference call (All attendants) 4. Normal call

What are the pre flight checks for Type I cabin door and Type C emergency exit doors? (3)

1. Ensure arming lever is in the disarmed position 2. Ensure safety pin is installed 3. Ensure slide/slide raft pressure gauge is in the green zone

Closing Type I cabin door in NORMAL situation: (5)

1. Grasp one of the door assist handles 2. Press the gust lock 3. Move the door towards yourself by using the door assist handle 4. When the door is in front of its frame, pull the door inwards and lower the door control handle 5. Check whether the door is locked correctly - the door locking indicator must indicate LOCKED

Type I cabin door external opening: (3)

1. Look through the observation window and make sure cabin pressure warning indicator light does not flash 2. Push in the flap and grasp the handle, lift the handle fully up to the horizontal green line 3. Pull the door outwards and sideways until it locks in its fully open position

How do you disconnect a slide/slideraft? (4)

1. Open the girt bar flap to get access to the disconnect handle 2. To disconnect slide/slideraft from AC, pull the disconnect handle 3. The slide/slideraft is still moored to the AC by means of a mooring line 4. A hook knife is provided to cut the mooring line

Opening Type III emergency exit from outside: (Only opened in emergency situations) (2)

1. Push the red flap and the emergency exit collapses inside the aircraft 2. The slide will inflate automatically when the exit is opened (from inside or outside) and will not automatically disarm

What is the procedure for disarming Type 1 cabin doors and Type C emergency exit doors? (4)

1. Remove safety pin from stowage 2. Raise the arming lever 3. Insert the safety pin in the hole connected to the arming lever 4. Press the arming lever down to ensure correct stowage of safety pin

What is the procedure for arming Type 1 cabin doors and Type C emergency exit doors? (3)

1. Remove the safety pin 2. Lower the arming lever 3. Stow the safety pin in the hole in the support arm cover (type 1) or in the safety pin stowage pouch (type C)

What are the lavatory pre flight checks? (10)

1. Smoke detector not obstructed 2. Waste bin flap operational 3. Flush system operational 4. Hot and cold running water 5. Water shut-off valve locations known 6. All stowage compartments closed and secured 7. Passenger call button operational 8. "Return to Seat" sign is operational 9. Internal lights function correctly 10. Locking mechanism on lavatory door works properly

What is the Cabin warning for lavatory smoke detection? (5)

1. Triple chime from all loudspeakers 2. Red flashing indicator and SMOKE LAV on all AIP 3. Amber light flashing on related ACP 4. Amber light flashing on lavatory wall 5. Red indication SMOKE LAV on FAP and AAP

When do oxygen masks drop down? (3)

1. When cabin pressure reaches 14.000 ft 2. When they are manually activated by the flight deck 3. When oxygen unit is opened manually using manual release tool (MRT)

Where does the SCCM sit in A321?

1L inboard crew seat

Where does the SCCM sit in A320?

1L outboard crew seat

What does the flight deck oxygen system consist of?

4 full face quick donning oxygen masks that have 2 settings; 100% oxygen or mix of oxygen and cabin air

Which exits are usable exits in evacuation on land?

All exits

Which exits are usable exits in evacuation on water?

All exits may be used but type C emergency exits on A321 must be disarmed

When are Type III emergency exit doors armed?

Always, they are permanently armed and slide deployment is automatically activated by the opening of the exit

What light means lavatory smoke on the ACP?

Amber flashing light

What light means lavatory call on the ACP?

Amber steady light

Where can the Evacuation Alarm horn be silenced?

At all stations

How long is the emergency lighting system able to operate in case the standard aircraft power supply is not available?

At least 10 minutes

What light means passenger call on the ACP?

Blue steady light

Where are Type C emergency exit doors safety pins stowed?

In a safety pin stowage pouch under the crew seat

How is the slide/slideraft lighting system activated?

It activates automatically by the slide deployment

What happens when Type I cabin door is opened from the outside when armed?

It automatically reverts back to disarmed position

What is happening when we arm a door?

The slide/slide raft girt bar attaches the slide/slide raft to the aircraft structure by locking into two floor brackets

What are the NORMAL operation opening/closing procedures for Type C emergency exits?

They are only used in event of emergency evacuation (However they open/close the same as Type I cabin doors in normal situations)

What type of doors and slides are on A320 (NEO) doors 1L/R and 4L/R?

Type I cabin doors with dual lane slide/rafts

What type of doors and slides are on A321 doors 1L/R and 4L/R?

Type I cabin doors with dual lane slides or slide/rafts, detachable

What type of doors and slides are on A320 (BRO/SIS) doors 1L/R and 4L/R?

Type I cabin doors with single lane slides that can be detached

What type of doors and slides are on A320 doors 2L/R and 3L/R?

Type III emergency exits with dual lane off-wing slides, not detachable

What is the Type I cabin door slideraft capacity (normal and overload)?

Normal capacity: 44 pax Overload capacity: 55 pax

How is the flight deck escape panel opened in case of rapid decompression?

Panel can be removed from the cockpit side by pulling the quick release pin and kicking it open

What light means CCM/FD call on the ACP?

Red steady light

How long does the chemical generator provide oxygen after masks have been pulled down?

For at least 15 minutes

Who can turn on the Evacuation Alarm system?

The flight deck, CCM can send a notification to flight deck from FAP and they in turn activate it

When does the SMOKE LAV warning disappear from the FAP?

When all smoke has disappeared

How shall CCM answer a call?

By giving their name and the station they are located at

Who is responsible for briefing pax sitting by emergency exits?

CCM 1R

Who confirms checks to SCCM via interphone on A320/321?

CCM 4L

What should CCM do if a circuit breaker pops out?

Inform the commander, dont push it back in

How is flight deck entry procedure when no cameras are installed or system is inop?

CCM contacts flight deck via interphone before requesting entry and the flight deck shall check through the viewing lens before letting anyone in

What are the cabin depressurization warnings at each level of decompression?

Cabin altitude 9.500 ft: 1. Master warning sounds at flight deck Cabin altitude 11.300 ft: 1. Fasten seat belt signs illuminate 2. Cabin lights turn to Bright setting 3. EXIT lights illuminate Cabin altitude 14.000 ft: 1. Masks drop down 2. PA volume increases 3. Burning smell, abnormal noise, mist in the cabin

When are the lavatories locked?

During take off and landing and if the lavatory is inop

What do CCM have to do after the manual shut off valve in lavatory has been closed?

Switch off the water heater

What type of doors and slides are on A321 doors 2L/R and 3L/R?

Type C emergency exits with single lane slides, not detachable


Ensembles d'études connexes

Cost Price / Selling price and markup

View Set

Experimental Final Exam (from midterm)

View Set

Chapter 17 - Marketing Communication

View Set

Chapter 2 Key Terms Emergency Preparedness

View Set

Chapter 19: Documenting and Reporting (3)

View Set

Nursing Process Mastery Quiz RNSG 1324

View Set