A/C Final

Réussis tes devoirs et examens dès maintenant avec Quizwiz!

Where is the ambient temperature sensor usually mounted?

In Front of the Radiator

Which sensor might use an aspirator tube?

Inside vehicle temperature

A refrigerant leak can be detected by ________.

Looking for oily areas (visual inspection) Using an electronic leak detector Using a soap solution and looking for bubbles

What could be wrong if the A/C compressor clutch cycles on and off rapidly?

Low refrigerant charge

The ________ door is used to select air discharge location, such as floor, vent, or defrost.

Mode

A five-wire actuator uses two wires to power the ________ and three wires for a ________.

Motor; potentiometer

A faulty A/C system has a high low-side pressure and a high high-side pressure. Technician A says that the system is probably low on refrigerant. Technician B says that the system has a bad thermostatic switch. Which technician is correct?

Neither

What is the color of the plastic conduit used over high- voltage wiring to an electric A/C compressor?

Orange

Electrically powered A/C compressors should use what type of refrigerant oil?

POE

The basic designs of AC compressors include ________, ________, and ________.

Piston, vane, and scroll

A feedback potentiometer is used to ________.

Provide feedback to the controller as to the location of a door or valve

The air inlet door is set to ________ when "MAX A/C" is selected.

Recirculate air

Most piston compressors use what type of valves?

Reed

The HVAC control module uses ________ to control high current loads in the A/C system.

Relays

A compressor belt tensioner is bouncing rapidly with the engine running. What should the technician do?

Remove the tensioner and lubricate the dampener

The low-side pressure is low and the high-side pressure is higher than normal. What is the most likely cause?

Restriction on the high-side line

If a wire repair, such as that made under the hood or under the vehicle, is exposed to the elements, which type of repair should be used?

Solder and adhesive-lined heat shrink or crimp-and-seal connectors

Technician A says that PTC heaters can be built into a conventional heater core assembly. Technician B says that a PTC heater's electrical resistance will decrease as its temperature increases. Which technician is correct?

Tech A Only

An AC system is being checked for proper cooling. Technician A says to turn on the AC system and operate the engine at 1500 to 2000 RPM for 5 to 10 minutes before checking the outlet temperature. Technician B says that the temperature can be checked as soon as 1500 RPM is reached. Which technician is correct?

Tech A only

Both high-side pressures and low-side pressures are low with the engine running and the selector set to the air conditioning position. Technician A says that the system is undercharged. Technician B says the cooling fan could be inoperative. Which technician is correct?

Tech A only

The HEV electric compressor operates at a voltage of up to ________ volts.

230

AC vent temperature at the center outlet should be

35°F-45°F (2°C-7°C)

The pressure relief valve on a 134a A/C system will open at about ________ PSI

400

When testing a relay using an ohmmeter, which two terminals should be touched to measure the coil resistance?

86 and 85

What is a "reheat" system?

A system that cools the air through the evaporator then heats the air though airflow though the heater core

Most A/C performance tests include

All of these

What is the purpose of the clutch on an A/C compressor?

Allows the compressor to be turned on and off

What is used to help keep the passenger compartment warm during idle-stop (start-stop) operation?

An auxiliary electric water pump

Technician A says that the HVAC doors in an automatic system may be cable operated. Technician B says that the HVAC doors in an automatic system may be operated by electric servos. Which technician is correct?

B only

The AC compressor clutch is being checked to see if it is engaged. Technician A says that if the drive belt is moving, the compressor is working. Technician B says that the compressor will often "click" when it is energized and de- energized. Which technician is correct?

B only

Which of these ATC output devices provides a feedback signal to the electronic control module (ECM)?

Blend door actuator

Technician A says that a good relay should measure between 60 and 100 ohms across the coil terminals. Technician B says that OL should be displayed on an ohmmeter when touching terminals 30 and 87. Which technician is correct?

Botch techs

Technician A says that module communications networks are used to reduce the number of wires in a vehicle. Technician B says that a communications network is used to share data from sensors, which can be used by many different modules. Which technician is correct?

Both

In a schematic, a wire is labeled "0.8 BLK/WHT." This wire is ________.

Both 0.8 mm diameter and Black with a White stripe

A compressor speed (belt lock) sensor is used by the HVAC ECM to ________.

Both Prevent a locked-up compressor from destroying the engine drive belt and Determine if the compressor is running by comparing the compressor and engine speed signals

Technician A says that HEV compressors may be both electrically and belt driven. Technician B says that scroll type A/C compressors contain an oscillating scroll and stationary scroll to pressurize the refrigerant. Which technician is correct?

Both Techs

Two technicians are discussing variable displacement piston compressors. Technician A says that the wobble plate is moved to the high-angle position for maximum output when the cooling load is high. Technician B says that the wobble-plate angle is controlled by the pressure in the crankcase of the compressor. Which technician is correct?

Both techs

The compressor is working if the ________ of the compressor clutch is rotating.

Center

Cabin filters may be treated with ________ to help reduce odors.

Charcoal

While diagnosing an A/C concern the scan tool reads "Inside Air Temp = 90°" and "Ambient Temp = -38°". Shop temperature is 87°. What should the technician do?

Check the ambient sensor and connections

Water discovered on the floor on the passenger side of a vehicle is an indication of what problem?

Clogged evaporator drain

A complete circuit that is continuous from source through loads and back to ground has ________.

Continuity

High resistance in an electrical circuit can cause

Dim lights Slow motor operation Clicking of relays or solenoids

A clutchless damper drive is used with what type of AC compressor?

Electronic-controlled, variable displacement compressor

What is the control device used inside an electric A/C control actuator?

Eletric motor

Most A/C systems first pass the air through the ________ as it enters the vehicle.

Evaporator

In a system that is operating correctly, the lines and hoses on the high side should be

Hot to the touch

Technician A says that as the clutch drive hub is replaced, the air gap should be checked at three different places. Technician B says that the air gap is not important as long as the clutch coil resistance (in ohms) is correct. Which technician is correct?

Tech A only

Technician A says that oily residue on a fitting or hose can indicate a refrigerant leak. Technician B says that this residue is normal around most A/C fittings. Which technician is correct?

Tech A only

Two technicians are discussing compressor replacement. Technician A says that the new compressor already has the proper type and amount of oil installed. Technician B says that the included directions should be followed before installing the new compressor. Which technician is correct?

Tech b only

The door used to control interior temperature is called the ________ door.

Tempature-blend

A dual-zone A/C system allows for different ________ for the driver and passenger.

Temperatures

How is the AC compressor lubricated in an R-134a system?

The oil moves through the system simply with the movement of the refrigerant

An airflow (blend) door may be broken if

There is a clicking noise from the actuator motor assembly as it tries to move a broken door, Outlet temperature can change from hot to cold or from cold to hot at any time especially when cornering There is a change in the temperature when the fan speed is changed

Most recent HVAC actuators are recalibrated after replacement by

Using a scan tool or allow it to self-learn after being installed

In an operating A/C system, the outlet line from the evaporator should be

cool

Which type of DMM can measure current when clamped around a conductor?

inductive


Ensembles d'études connexes

Health exam 3 (STRESS, STD, SLEEP)

View Set

Chapter 4 the developing person psychology

View Set

CM CERTIFICATION TRAINING REVIEW

View Set

Principles of Management - Chapter 7 & 11

View Set

Functional Behavior Assessment - Midterm

View Set

Test 4-Capsules and Tablets (check answers)

View Set

Training and Development Final Exam

View Set