Additional Items
Receptacles in hallways (are / are not) subject to the general provisions for placement determined by wall space.
are not
Sliding panels in exterior walls (are / are not ) counted as exterior space.
are not
A hood fan (is / is not) permitted on a small-appliance branch circuit.
is not
A lighting outlet (is / is not) permitted on a small-appliance branch circuit.
is not
All receptacles installed in garages (must / must not) have GFCI protection.
must
________ provision permits the installation of a smaller conductor as a switch loop.
no
At least _______ wall switch-controlled lighting outlet(s) must be installed in hotels and motels.
one
A fastened-in-place appliance (shall / shall not) be connected to a small-appliance branch circuit.
shall not
In cord-connected showcases, the secondary circuit of each electric-discharge lighting ballast is limited to one ______________.
showcase
GFCIs are designed to trip when a ______ to ___________ mA difference between the ungrounded (hot) conductor and grounded conductor occurs.
4, 6
Glass door fixed panels in exterior walls (are / are not) counted as exterior space.
are
Household cooking appliances (are / are not) required on a load calculation.
are not
Hallways of less than ________ feet do not require a receptacle.
10
________ receptacles are permitted on a 15A overcurrent protective device.
10
The maximum distance between receptacles in a one-family dwelling is ________ feet.
12
___________ receptacles are permitted on a 20A overcurrent protective device.
13
Circuits, other than individual branch circuits, must be rated _______, _________, __________, ___________, and _________ amp.
15, 20, 30, 40, 50
Lampholders shall be constructed with shades or guards so combustible material is not subject to temperatures in excess of ______________ deg F.
194
A receptacle is required for any wall space ___________ feet or more in width.
2
The maximum distance to any receptacle for a kitchen measured horizontally is ______ inches.
24
Although receptacles located more than __________ feet above the floor are permitted, they are not counted as required receptacles.
5.5
Groups of not more than ________ showcases can be coupled together.
6
Receptacles in a one-family dwelling should be measured horizontally along the floor line so no point is more than __________ feet from a receptacle outlet.
6
Each outdoor receptacle must be accessible while standing at grade level and located not more than _________ above grade.
6'6"
All switches shall be located so they may be operated from a readily accessible place not more than ___________ from the floor to the center of the switch operating handle.
6'7"
___________ is required where receptacles are installed within 6' of the outside edge of a sink.
GFCI
_________ cable is the most common wiring type in one-family dwellings.
NM
Where receptacles are installed in the floor, the boxes that house the receptacles must be specifically listed for the ___________________.
application
The general provisions for receptacle placement by wall space do not apply to _________________.
bathrooms
No receptacle wall placement provisions exist for _____________ occupancies.
commercial
Supporting an enclosure from grade requires rigid support in the form of _________ or a ______________.
conduit, brace
Receptacles located inside cabinets or cupboards which do not serve kitchen countertop units (do / do not) require GFCI protection.
do not
A baseboard heater more than 12' (does / does not) eliminate the requirements of receptacle placement.
does not
A receptacle installed behind a refrigerator (does / does not) count as a required countertop receptacle.
does not
Other _________________ must not be electrically connected to showcases.
equipment
At least _________ 20A branch circuits are required for a one-family dwelling.
four
At least one wall switch-controlled lighting unit shall be installed in every _____________ room of a dwelling.
habitable
All balconies, decks, and porches that are accessible from __________ the dwelling unit must have the required receptacle outlet ______________________.
inside, regardless of size
Service hallways or corridors are not considered accessible to __________________.
pedestrians
In all installations, the number of circuits must be sufficient to supply the load ___________.
served
Permanently installed electric baseboard heaters equipped with factory-installed outlets or outlets provided by the manufacturer (shall / shall not) be permitted as required outlets for wall space.
shall
Flexible cords shall be connected to showcase _____________.
undersides
_______________ determines the minimum number of receptacles in a given dwelling.
wall space