Receptacles in hallways (are / are not) subject to the general provisions for placement determined by wall space.

are not

Sliding panels in exterior walls (are / are not ) counted as exterior space.

are not

A hood fan (is / is not) permitted on a small-appliance branch circuit.

is not

A lighting outlet (is / is not) permitted on a small-appliance branch circuit.

is not

All receptacles installed in garages (must / must not) have GFCI protection.

must

________ provision permits the installation of a smaller conductor as a switch loop.

no

At least _______ wall switch-controlled lighting outlet(s) must be installed in hotels and motels.

one

A fastened-in-place appliance (shall / shall not) be connected to a small-appliance branch circuit.

shall not

In cord-connected showcases, the secondary circuit of each electric-discharge lighting ballast is limited to one ______________.

showcase

GFCIs are designed to trip when a ______ to ___________ mA difference between the ungrounded (hot) conductor and grounded conductor occurs.

4, 6

Glass door fixed panels in exterior walls (are / are not) counted as exterior space.

are

Household cooking appliances (are / are not) required on a load calculation.

are not

Hallways of less than ________ feet do not require a receptacle.

10

________ receptacles are permitted on a 15A overcurrent protective device.

10

The maximum distance between receptacles in a one-family dwelling is ________ feet.

12

___________ receptacles are permitted on a 20A overcurrent protective device.

13

Circuits, other than individual branch circuits, must be rated _______, _________, __________, ___________, and _________ amp.

15, 20, 30, 40, 50

Lampholders shall be constructed with shades or guards so combustible material is not subject to temperatures in excess of ______________ deg F.

194

A receptacle is required for any wall space ___________ feet or more in width.

2

The maximum distance to any receptacle for a kitchen measured horizontally is ______ inches.

24

Although receptacles located more than __________ feet above the floor are permitted, they are not counted as required receptacles.

5.5

Groups of not more than ________ showcases can be coupled together.

6

Receptacles in a one-family dwelling should be measured horizontally along the floor line so no point is more than __________ feet from a receptacle outlet.

6

Each outdoor receptacle must be accessible while standing at grade level and located not more than _________ above grade.

6'6"

All switches shall be located so they may be operated from a readily accessible place not more than ___________ from the floor to the center of the switch operating handle.

6'7"

___________ is required where receptacles are installed within 6' of the outside edge of a sink.

GFCI

_________ cable is the most common wiring type in one-family dwellings.

NM

Where receptacles are installed in the floor, the boxes that house the receptacles must be specifically listed for the ___________________.

application

The general provisions for receptacle placement by wall space do not apply to _________________.

bathrooms

No receptacle wall placement provisions exist for _____________ occupancies.

commercial

Supporting an enclosure from grade requires rigid support in the form of _________ or a ______________.

conduit, brace

Receptacles located inside cabinets or cupboards which do not serve kitchen countertop units (do / do not) require GFCI protection.

do not

A baseboard heater more than 12' (does / does not) eliminate the requirements of receptacle placement.

does not

A receptacle installed behind a refrigerator (does / does not) count as a required countertop receptacle.

does not

Other _________________ must not be electrically connected to showcases.

equipment

At least _________ 20A branch circuits are required for a one-family dwelling.

four

At least one wall switch-controlled lighting unit shall be installed in every _____________ room of a dwelling.

habitable

All balconies, decks, and porches that are accessible from __________ the dwelling unit must have the required receptacle outlet ______________________.

inside, regardless of size

Service hallways or corridors are not considered accessible to __________________.

pedestrians

In all installations, the number of circuits must be sufficient to supply the load ___________.

served

Permanently installed electric baseboard heaters equipped with factory-installed outlets or outlets provided by the manufacturer (shall / shall not) be permitted as required outlets for wall space.

shall

Flexible cords shall be connected to showcase _____________.

undersides

_______________ determines the minimum number of receptacles in a given dwelling.

wall space