BOC 5.2 Process Flow on a P&ID
Control Valve
identify the valve symbol D in the figure
Globe Valve
identify the valve symbol F in the figure
double disc gate valve
identify the valve symbol G in the figure
Piston-Operated Valve
identify the valve symbol H in the figure
Solenoid valve
identify the valve symbol I in the figure
Angle valve
identify the valve symbol J in the figure
needle valve
identify the valve symbol K in the figure
Check Valve
identify the valve symbol L in the figure
Ball control valve with positioner
identify the valve symbol M in the figure
Butterfly control valve
identify the valve symbol N in the figure
Relief valve
identify the valve symbol O in the figure
Plug valve
identify the valve symbol P in the figure
1211
From the P&ID provided, identify the identification number of the propane pipeline.
35 feet 6 inch
From the P&ID provided, identify the maximum level setting for D-053
0 - 3000 PSIG
From the P&ID provided, identify the measuring range for PI-1654
0 - 200 PSIG
From the P&ID provided, identify the measuring range of pressure indicator after the centrifugal pump.
0 - 30 PSIG
From the P&ID provided, identify the measuring range of pressure indicator before the centrifugal pump.
25 feet 8 inch
From the P&ID provided, identify the minimum level setting for D-053
346.0 PSIG
From the P&ID provided, identify the set point for PZV-202B.
12"
From the P&ID provided, identify the size of the propane pipeline.
field mounted instrument needing electrical supply
From the instrument symbols provided, identify the instrument location and power supply needed for 'E'.
field mounted instrument needing instrument air
From the instrument symbols provided, identify the instrument location and power supply needed for 'F'.
field mounted instrument needing air and electricity
From the instrument symbols provided, identify the instrument location and power supply needed for 'G'.
instrument identification
From the instrument symbols provided, identify the instrument location and power supply needed for 'H'.
locally mounted instrument in the field
From the instrument symbols provided, identify the instrument location for A
board mounted instrument in the control room
From the instrument symbols provided, identify the instrument location for B
rack mounted instrument in the control room
From the instrument symbols provided, identify the instrument location for C
locally mounted instrument on a panel in the field
From the instrument symbols provided, identify the instrument location for D
process line
From the line designation symbol provided, identify the type of line for 'A'.
air/pneumatic line
From the line designation symbol provided, identify the type of line for 'B'.
electrical line
From the line designation symbol provided, identify the type of line for 'C'.
flow
Identify the main process variable being measured from the instrument abbreviation 'FIC'.
level
Identify the main process variable being measured from the instrument abbreviation 'LG'.
pressure
Identify the main process variable being measured from the instrument abbreviation 'PCV'.
temperature
Identify the main process variable being measured from the instrument abbreviation 'TS'.
Kettle type heat exchanger
Identify the process equipment from the equipment symbol provided.
dome roof tank
Identify the process equipment from the equipment symbol provided.
heat exchanger kettle type
Identify the process equipment from the equipment symbol provided.
process vessel
Identify the process equipment from the equipment symbol provided.
rotary compressor
Identify the process equipment from the equipment symbol provided.
instrumentation
P&ID contain more information about -------------in a process
legend
P&ID for a facility include a section that identifies all the symbols and abbreviation used on the drawing is known as -------------------
Right side
To trace a product, you would normally follow the product on a P&ID sheet from where it comes in on the left side to where it leaves the ———————-+
PZV
What is the abbreviation used for a pressure relief valve on a P&ID?
level control valve
What type of instrument is abbreviated LCV on a P&ID?