BP344
3.50 m.
Turnabout spaces should also be provided at or within ____ of every dead end;
max 0.48 m
Urinals should have an elongated lip or through type; the ___ height of the lip should be____
1.06 m
Vertical pull handles, centred at ____ above the floor, are preferred to horizontal pull bars for swing doors or doors with locking devices
less 2.0m higher
Walkway headroom should not be ___ than ___ and preferably ____
minimum 1.20 m
Walkways should have a ___ width of ___.
max 1:100.
Walkways should have a ____ cross gradient of ___
6.50 mm
Walkways should have a continuing surface without abrupt pitches in angle or interruptions by cracks or breaks creating edges above ____
Php 2000-5000
Any person violating the act should suffer a fine of ______ to _____
Less one month, one year
Any person violating the act should suffer a penalty of imprisonment of not ___ than _______ but not ______
greater 0.20 m, less 1.80 m
Any ramp with a rise _____ than _____. and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end, not ____ than ____from the foot of the ramp;
0.90 m to 1.20 m
Control panels and emergency system of accessible elevators shall be within reach of a seated person; centreline heights for the topmost buttons shall be between _____ to _____ from the floor;
min 1.20 m
Corridors shall have ___ clear width of ____.; waiting areas and other facilities or spaces shall not obstruct the minimum clearance requirement
not more than 1:12
Curb cut-outs should have a gradient ___
Feb 25 1983
Date of act's aporoval
1.20 m to 1.30 m
Manual switches shall be positioned within ____ to____ above the floor
0.20 m
Manual switches should be located no further than ____from the latch side of the door
max 25 mm
Thresholds shall be kept to a minimum; whenever necessary, thresholds and sliding door tracks shall have a ____ height of ____ and preferably ramped;
not less than 1.80 m
. A level area ___________. should be provided at the top and bottom of any ramp
min 1.70 x 1.80 mts
Accessible water closet stalls shall have a ___ area of __________
min 1.50 m x 1.50 m 1.20 m.
A ____ clear level space of ___________ shall be provided before and extending beyond a door EXCEPTION: where a door shall open onto but not into a corridor, the required clear, level space on the corridor side of the door may be a minimum of _____ corridor width
1.50 m
A circle of ___in diameter is a suitable guide in the planning of wheelchair turning spaces.
1 for every 50 up to 150, 100
Accessories, tenement houses and or row houses, apartment houses or town houses- ___ for every ___ units up to ___. Additional for every ____
1.80 m and 1.50 m
Entrances with vestibules shall be provided a level area with at least a____. depth and a ____. width;
0.30 m
A tactile strip_______. wide shall be installed before hazardous areas such as sudden changes in floor levels and at the top and bottom of stairs; special care must be taken to ensure the proper mounting or adhesion of tactile strips so as not to cause accidents
2.25 sq. m, min 1.50 m
A turning space of ________. with a ____ dimension of ______ for wheelchair shall be provided for water closet stalls for lateral mounting
1.20 m
A walkway from accessible spaces of ____. clear width shall be provided between the front ends of parked cars
min 1.10 m. x 1.40 m
Accessible elevators shall have a ____ dimension of __________
not more than 30.00 m
Accessible elevators should be located _______________. from the entrance and should be easy to locate with the aid of signs
min 3.70 m
Accessible parking slots should have a ____ width of ____
min 0.80 m
All doors shall have a ____ clear width of ____
braille signs
Button controls shall be provided with __________ to indicate floor level; at each floor, at the door frames of elevator doors, braille-type signs shall be placed so that blind persons can be able to discern what floor the elevator car has stopped and from what level they are embarking from; for installation heights,
min 20 mm, max 1mm
Button sizes at elevator control panels shall have a ___ diameter of ______ and should have a ____ depression depth of ______
6
Capacity Space= 301-500 Seating Wheelchair Seating= __?__
2
Capacity Space= 4-50 Seating Wheelchair Seating= __?__
4
Capacity Space= 51-300 Seating Wheelchair Seating= __?__
1 out if 26-50, 100
Condominiums/ Tenement houses- ___ out of __ to __, additional 1 for every __
20 min, 3 hr
Disabled passengers shall be given __ minutes to embark ahead of the ___ embarkation time
Max 1 hr
Disabled passengers should be allocated a ___ of ______ for disembarkation
0.82 m. and 1.06 m, 0.90 m
Doorknobs and other hardware should be located between ____ and ____ above the floor; ____ is preferred
0.30 m. to 0.40 m
Doors along major circulation routes should be provided with kick plates made of durable materials at a height of ____ to ____
more 4.0 kg, 1 kg
Doors should be operable by a pressure or force not ____than _____; the closing device pressure an interior door shall not exceed ___
min 0.90 m.
Dropped curbs at crossings have a width corresponding to the width of the crossing; otherwise, the ____ width is ___
more than 1:12
Dropped curbs shall be ramped towards adjoining curbs with a gradient not ______
max 1:20
Dropped curbs shall be sloped towards the road with a ___cross gradient of ___to prevent water from collecting at the walkway.
less 1.20m
Effective width of footways past any obstruction should not be ____ than ____
4
First class, premiere and air-conditioned buses shall have at least ___ designated seats for disabled persons near the door
less 50mm
Handrails attached to walls should have a clearance no ____ than ___from the wall.
1.0 m to 1.06
Handrails for protection at great heights may be installed at ___ to ___.
less 40 mm
Handrails on ledges should have a clearance not ___ than ____.
0.90 m and 0.70 m
Handrails shall be installed at ___ and ___ above steps or ramps.
30 mm to 50 mm
Handrails that require full grip should have a dimension of ___ to ___.
0.70 m and 0.90 m
Handrails will be provided on both sides of the ramp at _______ and ______ from the ramp level;
1.5 m 2 m, 10 m
Have central refuges of at least ____ in depth and preferably____, provided as a midcrossing shelter, where the width of carriageway to be crossed exceeds ___
1 for every 50 up to 150, 100
Hotel motel iins pension houses apartels- ___ for every ___ units up to ___. Additional for every ____ at ingress level
max 13 mm x 13 mm, more 6.50 mm
If possible, gratings should never be located along walkways. When occurring along walkways, grating openings should have a ___ dimension of ____________ and shall not project ___ than __ above the level of the walkway
less 1.20 m
If the footway width will be reduced to ____ than ___ because of the excavation, the temporary covering should extend across the whole of the footway
0.20 m
If unavoidable, loose materials temporarily stored on footways must be properly fenced and prevented from encroaching onto the main footway by the use of a kickboard at least _____ . high which will also serve as a tapping board for the blind
min 1.50 m max 12:00 m
In lengthy or busy walkways, spaces should be provided at some point along the route so that a wheelchair may pass another or turn around. These spaces should have a ____ dimension of ____ and should be spaced at a ____ distance of ____ between stops
0.30m 7.5 mm
In order to aid visually impaired persons to readily determine whether a washroom is for men or for women, the signage for men's washroom door shall be an equilateral triangle with a vertex pointing upward, and those for women shall be a circle; the edges of the triangle should be____ long as should be the diameter of the circle; these signages should at least be____thick .
2
Jeepneys shall have at least ____ seats, preferably the front seats as designated seats for disabled persons.
Public works and highways
Minister 1 of BP344
Transportation and communication
Minister 2 of BP344
National commission concerning disabled persons
Minister 3 of BP344
6
Passenger trains shall have at least ___ designated seats per car for disabled persons nearest to the door
2
Passenger airplanes shall have at least ___ designated seats for disabled persons near the front exit/entrance door on a per aircraft type Basis.
1 for every 50 up to 150, 100
Private or off campus dormitories- ___ for every ___ units up to ___. Additional for every ____ at ingress level
min 0.10 m
Ramps shall be equipped with curbs on both sides with a ____ height of ____
min 1.20 m
Ramps shall have a ____ clear width of ____;
min 1.50 m x 1.50 m, max 12.00 m
Recesses or turnabout spaces should be provided for wheelchairs to turn around or to enable another wheelchair to pass; these spaces shall have a ____ area of_________ . and shall be spaced at a ___ of ______
5
Regular buses shall have at least ___ designated seats for disabled persons near exit/entrance doors
max 1.60 m min 1.40 m
Signs on walls and doors should be located at a ___ height of ____. and a ___height of ___.
less 1.20 m
Signs should not reduce the available footway width to ___ than ___
10%
Single detached/ Duplexes - how mang percent should be constructed
1 out if 26-50, 100
School or company staff housing units- ___ out of __ to __, additional 1 for every __
min 2.0 m
Should a sign protrude into a walkway or route, a ___ headroom of ___ should be provided;
min 1mm
Signage labelling public rooms and places should have raised symbols, letters or numbers with ___ height of ___
max 0.45 m, max 1.20 mts.
The ___ height of water closets should be ____.; flush control should have a ___ height of _____
min 0.90 m
The ___ width of a curb cut-out should be ___
max 1:12
The ____ gradient shall be ____- RAMPS
0.70 m
The comfortable clearance for knee and leg space under tables for wheelchair users is ___
0.70 m, 1.20 m, 0.40 m
The comfortable reach of persons confined to wheelchairs is from _____ to _____ above the floor and not less than _____ from room corners.
0.90 m/sec, less 6
The flashing green period required for the disabled should be determined on the basis of a walking speed of _______rather than 1.20 m/sec. which is what is normally used. The minimum period for the steady green (for pedestrians) should not be ____ than ___ seconds or the crossing distance times 0.90 m/sec., whichever is the greatest
1.00m
The height of the top of the rail should be at least _____. above the adjacent surface.
6:00 m, 1:12, not less than 1.50 m
The length of a ramp should not exceed ___. if the gradient is ___; longer ramps whose gradient is 1:12 shall be provided with landings ________________.;
1.10 m to 1.30 m
The length of wheelchairs varies from ____ to ____
not exceed 25 mm
The lowest point of a dropped curb should ______from the road or gutter.
1 20, 2
The minimum number of accessible water closets on each floor level or on that part of a floor level accessible to the disabled shall be ____ where the total number of water closets per set on that level is ____; and ____ where the number of water closets exceed 20
greater 0.35 m
The railing should incorporate a tapping rail to assist the blind, and this should not be ____ than ______ . above adjacent surface
0.6 m to 0.75 m
The width of wheelchairs is from ____to ____
straightforward right
To guide the blind, walkways should as much as possible follow _________ routes with _____ angle turns
slip-resistant
Tread surfaces should be a __________ material; nosings may be provided with slip-resistant strips to further minimize slipping .
100
When seating capacity exceeds 500, an additional is provided for each increase of __ seats
perpendicular
Whenever and wherever possible, accessible parking spaces should be _________ or to an angle to the road or circulation aisles
more 1:20 or 5%.
Whenever and wherever possible, walkways should have a gradient no ____ than _________
10
__ percent of the total number of units of government-owned living accommodations shall be accessible and fully usable by the disabled persons
max 0.80 m, 0.60 - 0.70 m, 0.50 m
___ height of lavatories should be ____. with a knee recess of __________. vertical clearance and a ____ depth
1 out of 4
___ out of ___ public telephones shall be accessible to disabled persons and shall be provided with visual aids required,
1
____ entrance level should be provided where elevators are accessible;
1 1
____ movable grab bar and ____ fixed to the adjacent wall shall be installed at the accessible water closet stall for lateral mounting; fixed grab bars on both sides of the wall shall be installed for stalls for frontal mounting;
Slanted, open stringers
________ nosings are preferred to projecting nosings so as not to pose difficulty for people using crutches or braces whose feet have a tendency to get caught in the recessed space or projecting nosings. For the same reason, __________ should be avoided