Reversing valve

A 4 way manifold controlled by a solenoid valve that can reverse the flow of refrigerant

Charge compensator tank

A canister w the heat pump's gas lines running through it

Reverse cycle defrost

A defrost method that reverses refrigerant flow through and air source heat pump

Water loop

A heat exchanger that circulates refrigerant through one passage and water through a separate but adjacent passage

Direct-exchange (DX) heat pump

A heat pump that circulates refrigerant through an outdoor coil placed in direct contact w the earth

Ground source heat pump

A heat pump that uses the earth as a heat source or a heat sink for producing the desired temperature in a conditioned space

Air source heat pump

A heat pump that uses the outside air as a heat source or a heat sink for producing the desired temperature in a conditioned space

When a heat pump is operating in COOLING MODE

A heat pumps reversing valve changes position, causing the refrigerant to flow in the opposite direction

Air coil

A length of tubing that contacts air and circulates refrigerant

Ground Coil

A length of tubing that contacts ground and circulates refrigerant

Ground loop

A length of tubing that contacts the ground and circulates water

Water coil

A length of tubing that contacts water and circulates water

Ideally, the refrigerant charge of a heat pump should be checked when the outdoor temp is

Above 70F for cooling and below 40F for heating

Solar panels

Absorb heat from the sun and transfer the heat to water in a heat storage tank

Biflow bypass TXV

Allows refrigerant to flow in either direction by using an internal check valve

Crankcase Heater

An electric resistance heater that warms the compressor dome prior to compressor start up

Heat pump compressors

Are required to operate at lower ambient temperatures than most ac compressors

Metering devices must

Be sized for a specific amount of refrigerant flow

Heat pumps use another refrigerant storage called a _______

Charge compensator tank

A heat pump requires more refrigerant in

Cooling mode

Ground source heat pump

EPA's most efficient heating and cooling system

E

Emergency heat or auxiliary heat

G

Fan control

W1

Heating stage 1 or auxiliary heat

The best way to eliminate bacteria and mold growth in a heat pump system is to

Install an ultraviolet light

In a heat pump the direction, of refrigerant flow through its compressor

Is always in the same direction

Biflow metering TXV

Meters refrigerant flowing in either direction

Flow check piston

Meters refrigerant passing through it in one direction and allows refrigerant to pass freely in the other direction

Fixed orifice metering devices and cap tubes are not well suited for

Most heat pump applications

The most convenient way to deal w the problem of snow accumulation is to ___

Mount the outdoor coil on risers

After blowing out a drain line, flush the drain line w ____

One part household bleach to four parts water

A heat pump's crankcase heats warms the compressor to vaporize any liquid refrigerant that may have entered the compressor during _____

Prior to start up (off cycle)

Instal a check valve in tubing that runs parallel w each TXV to allow

Proper refrigerant flow

B

Reverse valve

Heat pump compressors are

Similar to compressors in standard ac units

A heat pumps compressor is protected from liquid slugging by a

Suction line accumulator

Solar panels are sized to meet

The auxiliary heating needs of a heat pump

When a heat pump is operating in HEATING MODE

The outdoor coil functions as an evaporator by absorbing heat

Outdoor coil

The refrigerant coil that absorbs or expels heat for the indoor coil

Indoor Coil

The refrigerant coil that is located inside and warms or cools the air for the conditioned space

During the HEATING MODE, the gas line is colder than the liquid line, causing ____

The warmer refrigerant from the liquid line to condense and flow into the charge compensator tank

Air-to-water heat pump

Transfers heat between outside air and air inside a conditioned space using a hydronic system for heat distribution

Air-to-air heat pump

Transfers heat between outside air and air inside using forces air for distribution

Water source heat pump

Type of heat pump that circulates water through a secondary circuit that is laced underground or underwater

Direct acting reversing valves

Uses the direct mechanical action of the solenoid plunger to move the piston and sliding section of tubing inside the reversing valve/ used in smaller heat pumps

Pilot-operating reversing valve

Uses the pressure difference between the compressors suction and discharge lines to move its piston

3 major Occasions when auxiliary heat is needed

When outside temp is too low, during reverse cycle, and for emergency operation when a compressor is inoperable

During COOLING MODE, the gas line is warmer than the liquid line,

Which causes the liquid refrigerant in the tank to boil and circulate through the system as needed


Ensembles d'études connexes

Lab Simulation 1-1: Explore Server Manager and the MMC

View Set

Chapter 6 Egoism, Self-Interest & Altruism

View Set

Bones of the Appendicular Skeleton

View Set

Chapter 15: Maternal and Fetal Nutrition

View Set

AP Psychology Chapter 4 Study Guide

View Set

Chapter 14: The Protestant Reformation (14.3)

View Set

Intro to Networks Ch. 3: Network Protocols and Communications: Check your Understanding

View Set

Anatomy and Physiology chapter 1

View Set