What process is used to clean monitoring equipment between patient use
Disinfecting
What method can you use to calculate the ventriuclar rate of a cardiac rhythm when the R-R interval is regular?
Divide the number of large boxes between 2 R waves ino 300
What is the best method for obtaining a good recording from a handheld, ambulatory, post event cardiac monitor?
Ensure two of the four electrodes are pressed gently to the left of the sternum
What should be done when a patient reports that their demographic information is incorrect?
Follow the organizational procedure and correct the error immediately
What is sinus bradycardia?
HR < 60 bpm
During sinus rhythm, an early narrow complex beat without a P wave preceding it would be interpreted as
PJC
First degree AV block is determined by teh measurement of the
PR interval
The conduction system terminates with the
Purkinje network
While conducting a routine transtelephonic pacemaker check, the patient states he is short of breath, and atrial fibrillation is noted in the presenting rhythm strip. The technician's next step should be to:
Put the patient on hold and call his cardiologist
The first negative deflection noted in the QRS complex
Q wave
A PVC that occurs during the relative refractory period is referred to as
R-on-T phenomenon
Which waveform represents ventricular repolarization on an ECG strip?
T wave
What best describes asystole on an ECG
a flat line tracing
Atrial tachycardia is
a rapid arrhythmia which is irregular and occurs paroxysmally
A patient with a TTM suddenly begins slurring his words and complaining that he has tingling in his left arm. What is the most appropriate action?
activate EMS
A Parkinsonian tremor will typicall manifest itself on an ECG tracing as
an erratic baseline
The p wave on the electrocardiogram represents an electrical impulse that spreads through the
atria
Where is the most appropriate location ot place a "patch cardiac monitor"?
center of chest mid sternum
Atrial fibrillation is best defined as
chaotic, asynchronous electrical activity in atrial tissue
After completion of ECGs, the equipment must be
cleaned and secured per facility guidelines
Which of the following rhythms may be characterized by regular P-P and regular R-R intervals at different rates?
complete heart block
What occurs when a ventricle pacemaker senses electrical current from sources other than the heart?
oversensing
Where should the ECG tracing be placed after it has been obtained
per facility guidelines and protocols
In the absense of a release form, a patient's health information may be shared with the patient's ___ without committing a HIPAA violation
physician
What must be done promptly after recording an ECG rhythm?
provide to the interpreting practitioner
What is the proper procedure if your patient has a seizure during the ECG?
repeat ECG after the seizure is over
Which valves prevent the backflow of blood from the aorta and pulmonary arteries into the ventricles during diastole?
semilunar
A regular rhythm with a rate of 158 BPM and with a narrow QRS complex is best described as
supraventricular tachycardia
ECG preliminary findings are most frequently recorded by the
technician
A characteristic of third deg AV block is
the conduction of the atrial impulse failing to reach the ventricle
Atrial fibrillation with a slow ventricular response has an
ventricular rate less than 60 BPM
On standard ECG paper the horizontal lines are a measurements
voltage
Which rhythm is characterized by P waves with three or more different morhpologies
wandering atrial pacemaker
The patient requires a 30-day cardiac monitoring device. Which of the following items would be the least important education related to the patients self-monitoring?
what type of cardiac monitoring device is in use
In standard calibration ECG graph paper, a deflection of the tracing upward or downward by one large box, from baseline represents
0.5 mV
Normal sinus rhythm HR ranges from
60-100 BPM
In a normal sinus rhythm, the sinus node fires at a rate of
61-100 BPM
Which of the following essential tools are required to begin remote cardiac device monitoring?
- batteries - electrodes - adhesive tape - cardiac device
During a monitoring period which symptoms would be most appropriate for a patient to record?
- dizziness - chest pain - out of breath
Which of the following items would be considered standard instructions when placing a 24h monitoring device on a pateint in a clinical setting?
- explain the importance of not getting the monitor wet - encourage teh patient to leave the monitor on the entire time - inform the patient of physical limitations while the monitor is worn
Which of the following are types of artifact that need to be recognized during rhythm analysis. Choose four reponses
- somatic tremor - AC interference - junctional baseline - paced interference - wandering baseline - interrupted baseline
Patient education in self-monitoring includes with of the following:
- when to disconnect the device - what to do when the device emits an alert sound - what type of symptoms to record during the monitoring period x who to call in case of an emergency x how to wear the device while driving
The normal gain setting for ECG acquisition is ___ mm/mV
10
Which of these rates could be considered a junctional tachy
130 BPM (>100 BPM)
An ECG caliper measurement of peak to peak flutter waves is five small boxes. What is the atrial rate for this rhythm?
300 BPM
If a dual chamber pacemaker's ventricular lead senses a non-cardiac signal, what is most likely to occur?
failure to capture ventricle
Which of the following BEST describes idioventricular rhythm?
heart rate 20-40 BPM, almost always regular, no P waves preceding a wide QRS
A regular rhythm with a narrow QRS complex with no noted P waves and a rate between 40-60 BPM is nown as
junctional escape rhythm
Which cardiac chamber contains most of the muscle mass of the heart?
left ventricle
On an ECG strip pacemaker spikes without P waves or QRS complexes are seen. This is
loss of caputure
Supraventricular tachycardia is
narrow compelxed tachycardia greater than 150 BPM
An in-hospital telemetry technician arrives for his shift and notices that the report for the prior shift has not been completed. The telemetry technician should
notify the supervisor or senior technician of the situation to seek advice on how to proceed
The relationship between the conducted P waves and the QRS complexes in a sinus arrhythmia is
one P wave per QRS complex