Backup reserve

Also called Cold Standby Reserve

Spinning reserve

Also called hot standby reserve.

Diversity factor

Always greater than unity.

Demand factor

Always less than unity

Load factor

An index to the proportion of the whole time a generator plant or system is being worked to its full capacity.

Electronic meter

Contains no moving parts and can determine the numerous electrical parameters

230kV to 765kV

Extra High Voltage

Contingency reserve

Generating capacity that is intended to take care of the loss of the larger synchronized generating unit or the power import from a single grid interconnection, which is higher.

34.5kV to 230kV

High Voltage

Chronological appearance

If this load on the power supply station is plotted against the time periods in which these loads occur, it gives rise to what is known as the ___ ___ of the power demand and the time sequence.

Power

Is the rate of doing work

Load factor

It is always less than unity.

Load duration curve

It is the curve for a plant showing the total time within a specified period, during which the load equaled or exceeded the values shown.

Work

Joules

Power

Joules/seconds

Below 1kV

Low Voltage

1kV to 34.5kV

Medium Voltage

Demand

Most frequently expressed in terms of real power

Generation

One of the essential components of power systems

Capacity factor

Ratio of actual energy produced to the maximum possible energy that could have been produced during a given period.

Plant operating factor

Ratio of average load for a given period of time to the operating capacity in actual service only.

Plant operating factor

Ratio of duration during which plant is in actual service, to the total duration of the period of time considered.

Demand factor

Ratio of maximum demand of a system to be ts connected load is termed as demand factor.

Diversity factor

Ratio of the sum of individual maximum demand to the simultaneous maximum demand on the power station.

Backup reserve

Refers to a generating unit that has fast start capability and can synchronize with the grid to provide its declared capacity for a minimum period of eight hours.

Load demand

The ___ on a power system is governed by the consumers and for a system supplying industrial and domestic consumers, it varies within wide limits.

Demand factor

The actual maximum demand of a consumer is always less than his connected load since all the appliances in his residence will not be in operation at the same time or to fullest extent.

Spinning reserve

The component of contingency reserve, which is synchronized to the grid and ready to take on load.

Load duration curve

The curve which shows the variation of load on the electrical power station with respect to time.

Load factor

The ratio of the average load to the peak during a certain prescribed period of time.

Utility factor

The ratio of units of electricity generated per year to the capacity of the plant installed in the station.

Utility factor

The ration of maximum demand of plant to the rated capacity of the plant.

Capacity factor

The ration of the average load on a machine or equipment to the rating of the machine or equipment, for a certain period of time considered.

Daily, monthly, weekly or yearly

The variation of load can be considered as ___, ___, ___ or ___.

765kV to exceeding

Ultra High Voltage

High

___ load factor is desirable quality.


Ensembles d'études connexes

Water: Mountains to Sea Last Exam Slide Notes (lectures 19-24)

View Set

ESS3 Ch 12 practice quiz, Biology 1322 Exam 4

View Set

FL statutes, rules and regulations pertinent to life insurance--Chapter 11-Practice Questions

View Set

Chapter 3. Hypertext Transfer Protocol

View Set

Community Quiz 3 Practice Questions

View Set

ch 2 review exam part 2, Spanish 2, Lesson 11 Test

View Set