(PRIOR TO CONSTRUCTION) Drain plans are important in ensuring the design allows for proper ___________ of drains, wastes, and vents. For example: drain plans are used for trenching and excavating as elevations are used to determine the best plumbing design to accommodate the structure of the building.
as-built drawings
(PRIOR TO CONSTRUCTION) Drain plans are often consulted at the end of the project to produce ____-_______ ____________.
Future Refrences
(PRIOR TO CONSTRUCTION) Drain plans can be used for _________ _________.
elevations
(PRIOR TO CONSTRUCTION) Drain plans can be used to calculate __________ between existing municipal services and new building requirements.
Protection
(PRIOR TO CONSTRUCTION) Drain plans must show __________ against back flooding
Drain Plans
(PRIOR TO CONSTRUCTION) Locations of cleanouts, fixtures, floor drains, traps, backwater valves, and various storm drainage connections are some of the many things illustrated on _________ ________.
Illustrated
(PRIOR TO CONSTRUCTION) Many of the plumbing code requirements and local bylaws may be ____________ as drain plans and elevations.
Co-ordination Drawings
(PRIOR TO CONSTRUCTION) Other trades such as electricians, sprinkler fitters, sheet metal workers, and others produce ____-_____________ ______________ to assist in their own layout and design.
Calculate
(PRIOR TO CONSTRUCTION) To ___________ cost of excavation, trenching, compaction tests if required and backfilling
d
(PRIOR TO CONSTRUCTION) What two items in a drain plan are typically illustrated by design and sizing? a. Wastes b. Vents c. pipes d. a and b
Verify
(PRIOR TO CONSTRUCTION) ________ elevation of underground services required for new building versus available municipal existing services
Building Sewer
1
Roof Drain
1
Sanitary Building Drain
1
Foot
1 ________ = Approx .434 P.S.I
Imperial Gallon
1 ________ = Approx 10 lbs
P.S.I
1 ________ = Approx 28 inches water column
U.S Gallon
1 ________ = Approx 3.78 litres
Imperial Gallon
1 ________ = Approx 4.54 litres
Cubic foot water
1 ________ = Approx 6.25 Imp. Gallons
Cubic foot water
1 ________ = Approx 62.5 lbs
U.S Gallon
1 ________ = Approx. 8.33 lbs
BTU
1 ________ = Energy required to change 1 pound of water 1'F
Kilogram
1 ________ = approx 2.2 lbs
Meter
1 ________ = approx 3.281 feet or 39 3/8" inches
Litre of Water
1 ________ = exactly 1 kg
One
An 8" building sewer 75 meters in length would require ____ 1.2 meter manhole(s)
False
An accurate material take off may be done from a stack elevation.
laundry, faucet, available
An ideal method of priming a floor drain located in the basement of a single family dwelling is to use the ___________ tub _________ on the laundry tub, if one is _____________. (Answer Example: ANSWERONE, ANSWERTWO, ANSWERTHREE)
Barret Cleanout
An inline cleanout for cast iron mechanical joint piping will sometimes be referred to as a __________ __________ as well.
A
As discussed in the workbook, what are 2 of the 4 items thatwill cause a blockage in our drainage system? a. Improper grading and poor workmanship b. No cleanouts and misuse of plumbing fixtures c. Improperly placed cleanouts and undersized cleanouts d. Poor fixtures and pipe alignment
Thread Pitch
Center to center of the thread (Technical Terms)
Sanitary, property line
Combined systems interconnect the storm and ________________ building drains together at the _____________ ____________.
cold, supply
A commercial trap seal primer would be best connected to a horizontal _________ water ________ pipe (Answer Example: ANSWERONE, ANSWERTWO)
blocked, lead, seal
A disadvantage of commercial trap seal primers is that the anti siphon openings become ___________ and cause water to ___________ out of the trap ________ primer. (Answer Example: ANSWERONE, ANSWERTWO, ANSWERTHREE)
horizontal
A double TY branch fitting must not be used in _________ piping.
a
A double TY may be used if the barrel of the fitting is a minimum of 3 and the branches are ________, _________ or _________ inches a. 1 ¼, 1 ½, 2 b. 1 1/8, 1 ½, 2 c. 1 ¼, 2, 2 ½ d. ½, 1, 1 ½
b
A double TY, regardless of opening sizes, ifinstalled in a nominally horizontal pipe will: a. permit waste to flow upstream in the main drain in which it is installed b. permit waste from one branch to flow up the opposite branch c. cause solid waste to catch and build up on the weir of the fiting d. be quite acceptable
Vertical, Horizontal
A double Y branch fitting is one fitting which may be used in the vertical __________ but is unacceptable on ___________ drain piping. (Answer Example: "ANSWERONE, ANSWER TWO")
Horizontal
A double Y may not be installed in a piping which is ____________
Position, Orientation
A factor to consider when selecting a fitting for gravity drainage piping is the "_____________" or "_____________" within the system or, in other words, whether the fitting is installed in the horizontal or in the vertical position. (Answer Example: "ANSWERONE, ANSWER TWO")
Downstream, Testing
A fitting clean out is designed primarily for cleaning ______________ from the clean out and ____________ of the newly installed D.W.V. system. (Answer Example: "ANSWERONE, ANSWERTWO")
1 1/2, atmospheric
A funnel floor drain and a hub drain must have a minimum trap seal of _______ and if the static pressure is greater that the __________ pressure, the trap seal height must be added to the seal.
b
A galvanized drainage pipe should not be drilled, tapped or welded. To connect a pipe by those means could: a. cause blockage b. reduce the effective diameter of the main pipe c. result in destruction of the protective coatings d. cause all of the above
Break
A popular method of preventing back flow at primer connections is by providing air _________.
Sanitary Waste
A sanitary building drain may be defined as the horizontal drainage piping in or adjacent to a building or other structure that receives the discharge from the ____________ __________
Sanitary
A separate sanitary drainage system receives the discharge from the ___________ system only.
Storm
A separate storm drain receives the discharge from the __________ system only.
Supply, system
A serious hazard of a cross-connection is the possible ___________ of the potable water ___________ (Answer Example: ANSWERONE, ANSWERTWO, ANSWERTHREE)
Vertical, Horizontal
A single T or a double T branch fitting may not be used in either a _________ or a __________ drainage pipe. A TY branch fitting incorporates a curved weir in its design, thereby allowing a relatively smooth flow of waste. (Answer Example: "ANSWERONE, ANSWER TWO")
True
A stack elevation is used fora practical plumbing layout.
True
A stack elevation may be used for a training exercise to show the best way to connect fixtures, drains, vents, et...
Thread Nipple Chuck
A tool used to fabricate short lengths of pipe; usually 4 ½" and shorter length. A close to 4 ½" nipple can be fabricated by using a running thread coupling complete with a locknut and a length of pipe inserted into the coupling or a commercially fabricated nipple chuck.
Thread Engagement
Is the amount of pipe thread necessary to make a tight connection between pipe and fitting.
Threaded Engagement
Is the amount of pipe thread necessary to make a tight connection between pipe and fitting.
Cast Iron
Is very fire resistant and will not produce toxic gases, such as hydrogen cyanide, hydrogen chloride or dense smoke
7.5, 188
I he satic pressure registers a6" water column reading on a manometer he tap seal must be _________ inches or __________ millimeters (Answer Example: ANSWERONE, ANSWERTWO)
foundation drain, clog up
If a downspout was hooked-up into a ____________, it would eventually ____________, as the soil would be washed into the foundation drain. it would eventually as the soil
A vent must be installed and terminate to outside
If a manhole is sealed inside of a building, what must be installed?
A 4" fresh air inlet is to be installed within 1.2M upstream of the trap and vented to outside
If a plumbing system was built in the early 1900's and had a building trap, what was required upstream of the building trap, where was it installed and terminated and what was the minimum size of the piping?
A building trap on the storm building drain just upstream of the main cleanout
If a semi-combined system is installed as per code requirement today, what must be installed inside the building and where?
same level, primed equally
If a series of primer tubes is being served through a header ,l the priming tubes must connect at the __________ ___________ for all the floor drains to be ________________
two
If a steel pipe is properly threaded and tightened into a fitting, approximately how many threads will you see outside of the fitting?
Sump Pump
If a storm Building Drain enters the building above the level of the Foundation Drain, What must be installed to remove water from around foundation?
Blockages
Improper sizing, improper grading, poor workmanship, and misuse are all factors that cause what?
Gravity
In most cases, water is delivered from a priming device to a floor drain by
There is no difference
Ina combined drainage system, where is the connection between the sanitary and storm drainage?
Tensile Strength
Is a measurement of the force required to pull something such as a rope, wire, or structural beam to the point where it breaks. The _________ __________ of a material is the maximum amount of tensile stress that it can take before failure, for example breaking.
Compression Joint
Is a quick and easy method of joining both hub-less and hub and spigot cast iron pipe. There are two types of this joint that are discussed in the following slides.
Good
Is copper a good or poor conductor of heat?
Caulked Joint
Is ideal for joining hub and spigot pipe where a degree of rigidity is required. The disadvantages of this are that special tools and equipment are often required and the joints are somewhat time-consuming to construct.
Insulator
Is plastic more of an insulator or conductor of heat?
Electric Welded Tubing
Is produced when a strip of steel is passed through rollers to form the desired shape. The seam is then welded, forming a flash along the length on the inside and outside of the tube. The weld is then tested to ensure it meets the standard. Once the weld passes the testing process the tubing is formed to the exact size, straightened, and cut to length.
Cast Iron
Is quite heavy when compared to other drainage materials. It also has cost factors associated with it that are amongst it's disadvantages, such as; - Installation costs increased - Labour factor material costs.
Continuous Waste and Vent
Means a vent pipe that is a vertical extension of a vertical waste pipe and includes the vertical waste pipe.
Sanitary Unit
Means a water closet, urinal, bidetor bedpan washer.
Sanitary drainage pipe/system
Means all piping that conveys sanitary sewage to a place of disposal, including the sanitary building drain, sanitary building sewer, soil pipe, soil stack, waste stack and waste pipe but not the main sewer or piping in a sewage treatment plant.
Storm Drainage Pipe
Means all the connected piping that conveys storm sewage to a place of disposal and includes the storm building drain, storm building sewer, rain water leader, catch basin and area drain installed to collect water from the property and the piping that drains water from a swimming pool or from water cooled air conditioning equipment, but does not include a) A main storm sewer b) A subsoil drainage pipe, or c) A private sewage treatment and disposal facility designed for the treatment or retention of storm sewage prior to discharge to the natural environment.
Trap
Means fitting or device that is designed to hold a liquid seal that will prevent the passage of gas but will not materially affect the flow of a liquid.
Horizontal Branch
Means that part of a waste pipe that is horizontal and installed to convey the discharge from more than one fixture.
Foundation, Downstream
LOCATION REQUIREMENTS: A cleanout shall be installed in every building drain and every building storm drain as close as possible to the inner face of the ____________ wall where the drain enters the building and shall be installed ______________ from any building trap. (Answer Example: ANSWERONE, ANSWERTWO)
downstream
LOCATION REQUIREMENTS: Due to the grease content in waste from sinks, a cleanout shall be installed in the waste pipe of every sink immediately _____________ from the fixture trap. See Figure 2.16-14
3/4
LOCATION REQUIREMENTS: Every fixture trap serving a lavatory, a sink, or a laundry tray shall have, at its lowest point, a screwed plug that is removable for the purpose of cleaning the trap. The diameter of the plug shall be at least ___ inch.
Tin and Antimony
Lead is not permitted in our soldering for water distribution piping. What are the 2 elements that make up our common 'lead free' solder that we use?
Pressure Fittings
May not be used in drainage piping, as their design does not make allowances for the deflection of flow which is required in gravity drainage.
Storm Building Drains
Means a building drain that conveys storm sewage to a storm building sewer.
Fixture Outlet Pipe
Means a pipe that connects the waste opening of a fixture to the trap serving the fixture.
Continuous Vent
Means a pipe that is an extension of a vertical section of a branch or trap arm.
Building Sewer
Means a pipe that is connected to a building drain 1m outside a wall of a building and that leads to a public sewer or private sewage disposal system.d
Back Vent
Means a pipe that is installed to vent a trap off the horizontal section of a fixture drain or the vertical leg of a water closet or other fixture that has an integral siphonic flushing action and "back vented" has a corresponding meaning.
Fixture
Means a receptacle. plumbing appliance apparatus or other device that discharges sewage or clear water waste, and includes a floor drain.
Waste pipe
Means a sanitary drainage pipe that carries the discharge from a fixture directly to a waste stack, soil stack, sanitary building drain, and branch or sewage system.
Branch
Means a soil or waste pipe connected at its upstream end to the junction of 2 or more soil or waste pipes or to a soil or waste stack, and connected at its downstream end to another one, a sump, a soil or waste stack or a building drain.
Wet Vent
Means a soil-or-waste pipe that also serves as a vent pipe and extends from the most downstream (TERM HERE) fixture connection to the most upstream fixture connection.
Crimping, Clamping
Name 2 ways that PEX and fittings are connected together (Example: Answer, Answer)
g
Name 3 pieces of plumbing information you can get from a drain plan. a. Material take of, b. location of piping, c. location of stacks, d. location of cleanouts, e. sizing of piping, f. proper code venting, g. all of the above
j
Name 4 ways in which copper can be joined? a. Soft solder b. hard solder c. compression d. flared e. glued, f. corporation, g. compression (O-ring), h. Victaulic (compression) i. swage (solder) j. All of the above
priming, siphonage, oscillation
Non-evaporating devices do not offer protection against _______________ of a P-trap due to ______________ capillary attraction, ______________ evaporation. (Answer Example: ANSWERONE, ANSWERTWO, ANSWERTHREE)
Right-Hand Thread
Normal direction for a thread on pipe and fittings (Technical Terms)
7.5M
Not counting floors, what is the maximum length between supports for 3" cast iron vertical piping?
12 feet
Now that you have been exposed to the lengths of copper pipe on our racks in the plumbing shop, what is the common length of hard drawn copper?
Renovations, Additions
Plans are used to locate blockages when service is required and when renovations or additions are carried out. The owner usually keeps a full set of construction drawings to help with the maintenance of the building. (Answer Example: "ANSWERONE, ANSWERTWO)
Thermosetting
Plastic which hardens with heat and the addition of chemicals creates a reaction thus forming a permanent shape. They will not change shape with the re-addition of heat (PEX piping)
Underground water pipe (Usually a well pipe and pump system)
Polyethylene is black coiled plastic pipe. What is its common use?
Oakum
Prior to the 1940's, what was the other material besides lead that was used to fill a cast iron joint with a hub-spigot?
Hub and Spigot
Prior to the MJ coupling, how was cast iron soil pipe manufactured or connected?
False
Stack elevations are limited to housing and low rise residential buildings only.
False
Stacks cannot be sized from a stack elevation.
Barret
The clean out that has a rectangular cover bolted to a bell and spigot ftting is the _____________ clean out.
building sewer
The cleanout intalled in the building drain downstream from the trap is a code requirements and is installed to allow cleaning of the ____________ _____________
5, 1.5, 15
The code states that in a storm system installation, the testing pressure should be _______ ft/head or _________ meters above the upper-most joint in the system for a duration of _____ minutes.
downspouts, foundation
The code states that the branches that are not requre to be pat of the test for storm systems are ___________, sub-soil drainage branches of perforated pipes and ___________ drains
Handhold, Cleanout
The common trap fora group of floor drains must be __________ and equipped with a _____________ (Answer Example: ANSWERONE, ANSWERTWO)
25
The depth of lead or PC-4 used to secure a caulked joint shall not be less than ___________ millimetres.
38, 1 1/2
The depth of seal for traps serving floor drain is ______ millimeters, or _______ inches minimum (Answer Example: ANSWERONE, ANSWERTWO)
no restrictions, Y
There are ____________________ restrictions placed on double _________ (Answer Example: "ANSWERONE, ANSWERTWO")
Gluing
There are a few different methods of joining ABS, but which is the most common?
Vent
There are no restrictions placed on TY's when installed in ___________ piping.
Type 1
This coupling consists of a neoprene sleeve completely surrounded with a corrugated stainless steel sheath. Two stainless steel gear clamps are attached to the sheath for tightening purposes. (?/2 of the Compression Joints)
Running Thread
This is a long thread that does not have any taper, usually made tight with a locknut (Technical Terms)
90
When manholes are required in a building sewer with a trade of 18" the distance between manholes shall not exceed _______ meters
Cut, ream, clean
When preparing copper pipe for solder, which of the following is the most correct process?
Too much grade
When related to improper grading, this mistake results in the water moving at a high velocity, leaving the solids behind. The solids then tend to pile up at the slightest obstruction.
Oversizing
When related to improper sizing, this mistake results in the drain getting clogged because the flow is too shallow to "float" the solids to the public sewer.
Undersizing
When related to improper sizing, this mistake results in the flow becoming "sluggish" because the pipe is too full. The solids tend to pile up and the drain may become blocked throughout its entire length.
Sanitary
When required, a building trap is installed in the _____________ building drain only.
3/4"
When solder a %4" copper pipe and fiting together, how much solder off the spool does the workbook recommend?
B
Y Branch Fittings used correctly to change the direction of flow from "Horizontal" to "Horizontal" or from "Vertical" to "Horizontal" a) Vertical, Vertical, Horizontal, Vertical b) Horizontal, Horizontal, Vertical, Horizontal c) Horizontal, Vertical, Horizontal, Vertical d) Vertical, Horizontal, Vertical, Horizontal
Drilling, Tapping
USE OF APPROVED FITTINGS AND CONNECTIONS is a very poor method of joining drainage piping. This method will result in the branch protruding into the main line and also cannot provide the required deflection of flow of waste. This method will also produce a very weak connection. (Answer Example: "ANSWERONE, ANSWER TWO")
Welded Pipe Joint
USE OF APPROVED FITTINGS AND CONNECTIONS it will have sharp inside edges and will also cause any protective coating to be burned off, which in turn will result in accelerated corrosion of the piping material.
d
Up to 2" steel, which size of pipe have the same threads per inch which means you can use the same die heads for threading? a. 1/4 and 3/8 b. 1/2 and 3/4 c. 1", 1 ¼", 1 ½", 2" d. all of the above
Owner, Municipality
Upon completion of the project drain plans are often kept by both the _________ and the ____________. (Answer Example: "ANSWERONE, ANSWERTWO)
False
Vent loading cannot be shown on a stack elevation.
Vent, Drain
Vent piping must connect above the flood level rim of the highest fixture to prevent the _________ piping as acting as a ________ pipe. (Answer Example: "ANSWERONE, ANSWERTWO")
False
Vent sizing cannot be properly shown on a stack elevation.
1.68
Water Expands at ___________% for every 100'F Temperature change above 4'C
1700
Water Expands at _____________ times when changes to Vapour (steam)
D
What does the acronym RWL stand for when used on drain plan? a. Running Waste Leader b. Raining Waste Leader c. Running Water Leader d. Rain Water Leader
Philplug Cold Caulking Compund Cord
What does the trade name PC-4 stand for?
1
What is Polyethylene mixed with to make PEX? 1. Silane, Carbon, Silicon, and oxygen molecules 2. Silver, Carbon, Silicon, and carbon-dioxide molecules 4. Silane, mercury, Polyurethane, and oxygen molecules
21 feet
What is a common length that steel pipe is manufactured and distributed?
Beige
What is a typical color code for CPVC?
Chlorine
What is added to the chemical make up of PVC to make it CPVC?
70-73'F (or 20-22'C)
What is approximate room temperature?
d
What is glass piping typically used for? (a) When you want to see the drainage system for study purposes (b) When you have potential for blockages and want to see where the issues are (c) When you want to see how different fixtures affect the drainage system (d) Used primarily for chemical waste
Test Tee
What is located at the Private Drain Connection as shown in this graph
2
What is one of the reasons ABS pipe may not be permitted in commercial or industrial uses? 1. It is not strong enough 2. It gives off toxic fumes when it burns 3. It's inside surface is too rough and can cause blockages over time 4. It is not easily supported from the materials used in commercial (example, concrete and steel walls and ceilings)
e
What is pipe dope/thread sealant used for? Name 2 reasons for using it. a. Seals any imperfections in the threads. b. Acts as a lubricant to keep cool. c. Aids in separation for easier removal of joint later on. d. Helps reduce electrolysis. e. all of the above
Chemical Drainage
What is polypropylene pipe typically used for?
Chlorinated Polyvinyl Chloride
What is the acronym CPVC stand for?
Drain, Waste, Vent
What is the acronym DWV stand for?
Polyvinyl Chloride
What is the acronym PVC stand for?
PEX
What is the acronym for cross-linked polyethylene?
14.7PSI
What is the approximate pressure in the atmosphere around us?
10 pounds
What is the approximate weight of 1 imperial gallon of water?
100'C
What is the boiling point of water at atmospheric pressure?
C
What is the boiling point of water at atmospheric pressure? a. 0'C b. 32'C c. 100'C d. 212'C
Chlorine
What is the chemical that is lacking in polyethylene pipe with makes it more flexible?
TSP
What is the color coding and its representation when drawing plumbing pipes on a drain plan? Colour: 3 broken blue
Storm
What is the color coding and its representation when drawing plumbing pipes on a drain plan? Colour: Blue
DWV Venting
What is the color coding and its representation when drawing plumbing pipes on a drain plan? Colour: Broken (dotted) green
Sanitary
What is the color coding and its representation when drawing plumbing pipes on a drain plan? Colour: Red
Yellow
What is the color coding for type DWV Copper ?
Green
What is the color coding for type K Copper?
Red
What is the color coding for typeL Copper?
Red
What is the colour coding for type M Copper?
12 feet
What is the common length ofABS pipe manufactured?
Clevis Hanger
What is the common name for the hanger shown in this picture?
Riser Clamp
What is the common name for the hanger shown in this picture?
Floor Drain
To drain the floor area in case of emergency due to malfunction of a plumbing fixture.
Clevis Hanger (or swivel hanger)
What is the common name of support for horizontal cast iron piping?
Strap Hanger
What is the common name of the hanger shown in this picture?
Riser Clamp
What is the common name of the support for vertical cast iron piping?
Snap Cutters
What is the common terminology or name to the cast iron pipe cutter?
Acidic Waste
What is the common use for glass piping?
A hub drain protrudes through the floor and has a flood level rim
What is the difference between a hub drain and a floor drain?
One has a sheeth around it
What is the difference between the type 1 and the type 2 MJ clamps used to connect cast iron soil pipe?
Initial cost of installation (More material, labour etc)
What is the disadvantage of a separate system compared to a combined system?
Floor Drain
What is the green location on the graph presented?
Municipal Sewers
What is the green location on the graph presented?
Private Drain Connection
What is the green location on the graph presented?
Property Line
What is the green location on the graph presented?
Water Closet
What is the green location on the graph presented?
Hub drain has a flood level rim
What is the main difference between a floor drain and a hub drain?
0.2%
What is the maximum allowable lead contend in our water distribution pipe and fitting system?
15M
What is the maximum distance between cleanout on a4" sanitary Building Drain?
C
What is the maximum distance between cleanout on a4" sanitary Building Drain? a. 4.5M b. 7.5M c. 15M d. 30M
15 M
What is the maximum distance between cleanouts on a 3" horizontal branch (ABS)?
6M
What is the maximum distance between cleanouts on the drain fora kitchen sink?
C
What is the maximum distance between cleanouts on the drain fora kitchen sink? a. 3M b. 4.5M c. 6M d. 15M
Every Second Story (or 7.5M)
What is the maximum distance between vertical supports for piping?
1.2M
What is the maximum horizontal distance between supports for 2" ABS pipe?
1.2M
What is the maximum spacing between horizontal supports for ABS pipe?
3 M
What is the maximum spacing between horizontal supports for cast iron soil pipe?
6M
What is the maximum spacing for a cleanout on a kitchen sink drain?
210
What is the maximum temperature of water permitted through CPVC piping ? (answer in degrees Fahrenheit)
210'F
What is the maximum temperature permitted through CPVC piping?
1000ºF
What is the melting point of solder that differentiates hard solder from soft solder?
1,000ºF
What is the melting point of the solder that differentiates the difference in the 2 types of solders?
1.2M
What is the minimum diameter at the base of a manhole?
150mm
What is the minimum length of pipe that must penetrate through the roof for a vent terminal?
4"
What is the minimum size of Sanitary Building Drain?
C
What is the minimum size of Sanitary Building Drain? a. 2" b. 3" c. 4" d. Same size as the incoming building sewer
4"
What is the minimum size of Storm Building Drain?
4"
What is the minimum size of a floor drain
3"
What is the minimum size of a floor drain if we do not connected vent pie to it?
3"
What is the minimum size of a floor drain that is not separately vented?
2"
What is the minimum size of a floor drain?
4"
What is the minimum size of building trap on the sanitary building drain if one is required?
4"
What is the minimum size of cleanout on a 4" drainage pipe?
D
What is the minimum size of cleanout on a 4" drainage pipe? a. 1 1/2" b. 2" c. 3" d. 4"
3"
What is the minimum size of our main stack from its base to the roof terminal?
3/8"
What is the minimum size of pipe that conveys water to a floor drain or hub drain for the trap seal priming of the trap?
3/4"
What is the minimum size of the cleanout plug on ap-trap when required?
B
What is the minimum size of the cleanout plug on ap-trap when required? a. 1/2" b. 3/4" c. 1" d. Same size as the trap
1200mm
What is the minimum width of a manhole at its base?
D
What is the minimum width of a manhole at its base? a. 500mm b. 750mm c. 1000mm d. 1200mm
Acid waste-chemical waste
What is the most common use for polypropylene piping as mentioned in the workbook?
Riser Clamp
What is the most common vertical support mentioned in our workbook?
1
What is the most common way of connecting ABS pipe to fittings? 1. Glued 2. Heat welded 3. Threaded 4. MJ Couplings
Bevelled End
What is the name of the 'end' of the glass pipe when it comes from the manufacturer?
Copper Oxide
What is the name of the 'film' on the outside of copper that we clean off before we solder?
Beveled and plain
What is the name of the 2 different types of ends of glass piping?
Snap Cutter
What is the name of the cutter used to cut cast iron soil pipe?
Plain End (or cut end)
What is the name of the end of the glass pipe when it is field cut on site?
Copper Oxide
What is the name of the film thatis on the copper pipe and fitting that must be removed in order to accomplish a soldered joint?
Symmetrical Fitting
What is the name of the fitting that has several connections on it from different angles? Sometimes known as 'Toronto' or 'Ottawa' fitting.
Slip Joint adapter
What is the name of the fitting/joint that connects the tailpiece ofa kitchen sink to ABS pipe and fittings?
Swage
What is the name of the joining method for copper pipe when a tool is used to expand the pipe so another pipe can fit inside to be soldered?
Air gap (or Air Break)
What is the name of the vertical separation of piping that must be used to protect our potable water from getting contaminated from our drainage system?
c
What is the only remedy to a poorly constructed joint or connection is often a factor in creating a blockage, and the blockage will likely reoccur regularly at the same point. a. repair the joint b. completely reconstruct the joint, c. both a and b
99.9%
What is the percentage of copper manufactured in copper pipe?
Water hammer
What is the plumbing term used to describe shock waves in our water distribution piping that is typically caused by quick closing vales?
Capillary Action
What is the plumbing term used when solder is 'drawn' into the fitting to accomplish a leak-proof sealed joint?
Rain Water Leader
What is the plumbing terminology for the piping that runs inside a building that drains a flat roof?
Backwater Prevention
What is the plumbing terminology used to protect the drinking water from the sewage water when we connect a trap seal primer to a floor drain
Keep Water in Trap
What is the purpose of a trap seal primer?
Keep the foundation + Footing dry
What is the purpose of connecting a foundation drain to storm piping?
False
Trap seal primers for floor drains do not need to be shown on a stack elevation.
False
Trap types and sizes are shown on a stack elevation.
a
What is the purpose of pipe dope or thread sealant when used on a steel threaded joint? (a) To aid is sealing the joint in case there are damaged threads (b) To create friction and heat to help seal the threaded joint (c) To aid in tightening the joint (d) To aid in the flow of liquid or gas going through the joint
6
What is the purpose of putting pipe dope or a thread compound/sealant on the threads before connecting a fitting? 1. To avoid scratching the wall of the thread to avoid wear and tear 2. Used as a sealant 3. Allowing for the pipe to be used longer 4. Avoid causing damage to other pipe's threading 6. void replacement for as long as possible.
They Serve to vent the municipal sewer
What is the purpose of the sanitary building sewer, sanitary building drain and main stack sizing requirements? What purpose do they serve?
Left Hand Thread
What is the reverse thread also known as?
Capillary Action
What is the scientific term used when solder is 'pulled' into the copper joint?
Snap Cutters
What is the term used for the tool used to cut cast iron piping?
Gang Trap
What is the terminology used for a trap that receives discharge from more than 1 floor drain?
Trap Seal Primer
What is the terminology used for the piping that conveys water to keep the floor drain trap filled with water?
Seamless Tubing
is manufactured using a process called "extrusion". During this process a solid steel bar is pierced through the centre using a die, turning the solid round into a round tube. There are two different ways of producing this: Cold Drawn Seamless: Good surface finish - Superior machinability - Increased dimensional tolerances - High strength to weight ratio Hot Finished Tubing: Cost effective material - Good Machinability - Wide range of sizes
A
lf 2 pipes need to cross each other on a drain plan, how is this shown? a. The lower pipe is broken line under the upper pipe b. At dotted line is shown close to the crossing of pipe c. A bolder color is used for the upper piping d. lt is not shown and only assumed they are not connected
Cleanout
means fitting access in a drainage system or venting system that is installed to provide access for cleaning and inspection and that is provided with a readily replaceable air tight cover.
Blue (Broken lines)
(Colour Coding) Trap Seal Primers
Building Control Valve
16.
trapped, vented, primed
A funnel floor drain and a hub drain must be and ____________, ______________, and ___________
4" Cleanout
3
Vented
Every fixture must be ________.
Female Iron Pipe
F.I.P (Technical Terms)
Red
List the color code for the following weights of copper: M
Chlorinated Polyvinyl| Chloride
What does the acronym CPVC stand for?
Male Iron Pipe
What does the acronym MIP stand for?
Outside Diameter
What does the acronym O.D. stand for?
Polyvinyl Chloride
What does the acronym PVC stand for?
Rain Water Leader
What does the acronym RWL stand for when used on drain plan?
Green (broken lines)
(Colour Coding) Colour Code for vents
red
(Colour Coding) Colour code for sanitary and wet vents
Blue
(Colour Coding) Colour code for storm vents
d
(PRIOR TO CONSTRUCTION) Drain plans should include a) the best location of stacks and most economical method of installation, b) vent terminals information c) all appurtenances to be installed. d) all of the above
Material, Labour
(PRIOR TO CONSTRUCTION) illustrates fittings and pipe to scale required in order to prepare estimates for both ________ and _______ (Answer Example: "ANSWERONE, ANSWERTWO)
Dimensions
(PRIOR TO CONSTRUCTION) By convention, some code requirements are included such as: (ANSWER) related to the trapping and venting of a building trap and also the (ANSWER) necessary to provide information about drain plans.
Fixture Unit
(as applying to drainage systems) means the unit of measure based on the rate of discharge, time of operation and frequency of use ofa fixture that expresses the hydraulic load that is imposed by that fixture on the drainage system. Professor Roy Hunter in the early 1940's derived from his research that 1 fixture unit was equal to 1cu Ft. of water to be discharged in a11/4 inch pipe in a 60 second period at 2f. per sec velocity. The time allowed was calculated from the start of the flush to a point 5f. from the weir, where the air enters the fixture branch.
Ductile
(of a metal) able to be drawn out into a thin wire - Able to be deformed without losing toughness; pliable, not brittle.
Additional Circuit Vent
11
Vertical Leg
11
Down Spout
11.
Branch Vent
12
Horizontal Branch
12
Water Distribution Center
1.
Nominal
1. (of a role or status) existing in name only 2. (of a price or amount of money) very small; far below the real value or cost 3. (of a quantity or dimension, especially of manufactured articles) stated or expressed but not necessarily corresponding exactly to the real value 4. Relating to, headed by, or having the function of a noun
Mandrel
1. A shaft or spindle in a lathe, to which work is fixed while being turned 2. A cylindrical rod around which metal or other material is forged or shaped.
Schedule
1. Is the term used to describe the thickness of a pipe. The outside diameter of a pipe is the same for all the _______ in particular nominal pipe diameter. Standard standard pipe _________ or pipe sizes as given by ANSI / ASME B36. 10M and API 5L. 2. The ___________ number on pipe products relates to the thickness of the wall on the pipe: as the number increases, the thicker the wall becomes. Also, while the ____________ number can be the same on different sized pipes, the actual wall thickness will be different.
Where, Drains
1. Ontario plumbing code regulations state ___________ floor drains must be installed, the plumbing code indicates how floor ________ must be installed
Tensile
1. Relating to tension 2. Capable of being drawn out or stretched
Branch Vent
10
Relief Vent
10
Foundation Drain
10.
Fixture Drain, 4.8, 16
10. l the floor drain referred toin question 9 was 4 inches trade size, and the fixture drain was installed wth a slope of1 50. connected to the sanitary building drain a vent would be required when the length of the ____________ _________ exceeded _________ or meters ________ feet (Answer Example: ANSWERONE, ANSWERTWO, ANSWERTHREE)
Roof Flashing
12.
Individual Vent
13
Stack Vent
13
Venting System
13.
Stack Vent
14
leader
14
Bathroom Group
14.
Stack Vent
15
Water Closet
15
Kitchen Sink
15.
Wet Vent
16
Storm Building Drain
17
Water Meter
17.
Sewege Sump Pump
18
Hot Water Tank
18.
Dual Pump
19
Cleanout
19.
Building Drain
2
Certified Flashing
2
Fixture Drain
2
Curb Stop
2.
Vehicular
3 a floor drain has a manufacture body, with a heavy metal grate having small openings, the expected traffic would be _________ traffic.
Laundry Tub
20.
Primer
21.
Back Water Valve
22.
Fixture Outlet Pipe
3
Vent Header
3
Grade Level
3.
e
A clean out shall be installed as close as is practical to the base of; a. Soil Stacks b. Waste Stacks c. Rain Stacks d. Water Leaders e. all of the above
Sanitary, Storm
A combine public sewer receives the discharge from both the __________ system and the ____________ systems
4
3. What is the minimum amountof cleanouts required on a storm building drain that is 17 meters in length and the backwater valve on the foundation drain is located 10 meters from the point of entry into the building?
Horizontal Branch
4
Main Stack
4
Vent Terminal
4
Public Watermain
4.
Water Service Pipe
5.
Fixture, Building, 3"
5. (1/2) A floor drain does not require an additional vent when its ______________ drain connects to the sanitation _____________ drain, and the size of the floor drain is __________ minimum.
Fixture drain, 450
5. (2/2) The minimum length of the _______________ _____________ serving the floor drain must be __________ meters.
Pressure
A commercial trap seal primer delivers water to a floor drain through a valve that is operated by ___________ differential.
c
A backwater valve is required to be accessible. Can it be used as a cleanout access? a. No, it was not installed for this purpose b. Yes, there's no issue to concern. c. Only if the access to the line is downstream of the gate and the gate seat. d. Only if the access to the line is upstream of the gate and the gate seat
p-trap, TY, hole clean out
A building trap is made the same way a run trap is made, with a 4 inch ________, a ________ and a _________ __________ _______________
Individual Vent
5
Septic Tank
5
Stack Vent
5
Sewer
A building trap receives the waste from the ___________ drainage system.
Circuit Vent
6
Floor Drain
6
Trap Arm
6
Building Sewer
6.
3" Vent Stack
7
Continuous Vent
7
Individual Vent (back vent)
7
Public Storm Sewer
7.
depression, finished grade
7. If soil and grit are being are being washed into the foundation drain, a ______________, is noticeable around the surface of the ______________ along the foundation wall. is noticeable
Dual Vent
8
Individual Vent
8
Waste Stack
8
Public Sanitary Sewer
8.
Branch Vent
9
Vent Sack
9
Building Drain
9.
Brass, Non-corroding
A clean out plug shall be of __________ or other equal ________________ material.
BTU
= (mass in lbs) x (temp change in 'F) x Specific Heat
Latent Heat Fusion
= 144 BTU/lb
Latent Heat Vaporization
= 970 BTU/lb
atmosphiric pressure
= Approx 14.7 PSI
room temperature
= Approx 21 'c or 72 'f
Three
A 36" building stom sewer 475 meters in length would require _____ 1.2 meter manhole(s).
Three
A 4" building drain 17 meters in length would require at least____clean outs
One
A 6" building sewer 100 meters in length would require ___ 1.2 meter manhole(s).
Blockage, System
A 90° bend installed in drainage piping should not have a radius less than the diameter of the pipe. A lesser radius is liable to cause a _____________ in the piping ______________ (Answer Example: "ANSWERONE, ANSWERTWO")
vertical, horizontal
A 90° short sweep elbow should not be used to change direction from __________ to ____________ (Answer Example: "ANSWERONE, ANSWERTWO")
sharp
A 90°elbow must not be installed in drainage piping if its curvature is too _______.
Turning Radius
A 90°elbow of 4" or less must have a __________ _________ equal to the nominal pipe diameter.
Dual Venting
A Double Waste Fitting used in "_____ _________" applications
Horizontal, Vertical
A TY Branch Fitting used Correctly to change the direction of flow from "________" to "_________" (Answer Example: "ANSWERONE, ANSWER TWO")
curved
A TY branch fitting incorporates a _________ weir in its design, thereby allowing a relatively smooth flow of waste.
Up, Across, Blockage
A TY installed in a horizontal pipe to receive another horizontal pipe is not acceptable because waste will run _________ and _________ in the horizontal piping, and eventually may cause a __________ (Answer Example: "ANSWERONE, ANSWERTWO, ANSWERTHREE")
Actual Pipe Size
A.P.S (Technical Terms)
American Standard Pipe Thread
A.S.P.T (technical terms)
building drain
Abbreviation Used: B.D
Building Sewers
Abbreviation Used: B.S
Back Water Valve
Abbreviation Used: B.W.V
Cleanout
Abbreviation Used: C.O
downspout
Abbreviation Used: D.S
Fresh Air Inlet
Abbreviation Used: F.A.I
Foundation Drain
Abbreviation Used: F.D (Not Floor Drain)
floor drain
Abbreviation Used: F.D (Not Foundation Drain)
foundation drain connection
Abbreviation Used: F.D.C
kitchen sink
Abbreviation Used: K.S
laundry tub
Abbreviation Used: L.T
Private Drain Connection
Abbreviation Used: P.D.C
Property Line
Abbreviation Used: P.L
rainwater leader
Abbreviation Used: R.W.L
Street Line
Abbreviation Used: S.L
Soil Stack
Abbreviation Used: S.S
trap seal primer
Abbreviation Used: T.P.S
Test Tee
Abbreviation Used: T.T
water closet
Abbreviation Used: W.C
waste pipe
Abbreviation Used: W.P
waste stack
Abbreviation Used: W.S
Schedule 40
According to the workbook, what is the minimum weight of PVC piping if threading it is required?
slope
All bath wastes must have the _____________ connected along with the drains.
True
All drain, waste and vent piping above the basement floor should be sized on a stack elevation.
slope
All drainage piping must be drawn with a reasonable amount of ___________ or grade
Trap Seal
All floor drains must be equipped with a ________ _________ primer.
trap seal primer
All floor drains must have a ___________ __________ ___________ connection.
Plastic
Are about 1/12th to 1/5th the weight of steel which makes installations easier and more economical.
14.7 PSI
Approx. how many PSI is atmospheric pressure?
62.5 lbs
Approx. how much does one cubic foot of water weigh?
Thermoplastic
Approximately 95% of plastic piping used is the thermoplastic type. It is plastic which softens with heat and change its shape. When cooling takes place it hardens again with little or no loss of tensile strength.
28 inches
Approximately how many inches water column is equal to 1 psi?
C
Approximately how many inches water column is equal to 1 psi? a. b. c. d.
4.54
Approximately how many litres in an imperial gallon of water?
62.5 lbs
Approximately what does 6.25 imperial gallons of water weigh?
Plastic
Are non-conductors of electricity which acts as an extra safety margin to the industry.
1M
At what depth/height does a manhole require a ridged ladder installed in the manhole?
A
At what point does the Sanitary Building Drain change its name to Sanitary Building Sewer? a. 1M outside the foundation wall b. At the property line c. Where it connects to the municipal sewer d. At the base of the main stack
8"
At what size is a manhole required instead of a cleanout on a building sewer?
C
At what size is a manhole required instead of a cleanout on a building sewer? a. 4" b. 6" c. 8" d. 12"
32
At what temperature does water freeze (degrees Fahrenheit)?
0
At what temperature does water freeze (degrees celsius)?
73ºF (23ºC)
At what temperature is thermoplastic piping pressure tested at?
100
Boiling Point For Water: Answer for Degrees Celsius
Old
Building traps are more commonly found in ___________ neighbourhoods.
2, blockage
Building traps are not commonly installed because they have an adverse effect on the drain, waste and vent system. The minimum velocity of the building drain required to ensure the proper flow of liquids, paper, suds and solids is ____ ft/sec. The trap restricts the flow and creates ________________.
Separate, drain
Buildings located in older cities and towns during major renovations would require that a ________________ system be installed and allow storm water to ____________ separately.
No
Can TY (Directional fitting) be used on its side to accept drainage from 2 horizontal branches?
No
Can a double Y fitting be used for drainage in the horizontal position?
Brass
CONSTRUCTION REQUIREMENTS: 1. Every screw, bolt, nut and washer shall be of _______ or equally corrosive resistant material.
airtight
CONSTRUCTION REQUIREMENTS: A cleanout plug shall be of brass or other equally non-corroding material and upon being removed and replaced a number of times, shall retain an ___________ seal.
Leak
CONSTRUCTION REQUIREMENTS: No cleanout shall _____ when the pipe in which it is installed is tested in accordance with the Code.
F
Cast Iron does not have superior noise suppression, which doesn't significantly reduces noise caused by fluid transmission, expansion and contraction (T/F)
T
Cast Iron has superior noise suppression, which significantly reduces noise caused by fluid transmission, expansion and contraction (T/F)
F
Cast Iron is not fire resistant and will produce toxic gases, such as hydrogen cyanide, hydrogen chloride or dense smoke. (T/F)
T
Cast Iron is very fire resistant and will not produce toxic gases, such as hydrogen cyanide, hydrogen chloride or dense smoke. (T/F)
Copper
Cast Iron, ________ and steel pipe have long histories of being used for drains, wastes, vents, waterlines, and process plumbing.
Steel Pipe
Cast Iron, copper and _____ _____ have long histories of being used for drains, wastes, vents, waterlines, and process plumbing.
Plastic
Cast Iron, copper and steel pipe have long histories of being used for drains, wastes, vents, waterlines, and process plumbing. __________ is the newest material on the scene and has been used for the past four decades. In the past few years even more ___________s have been developed
Nominal Pipe Size
N.P.S (Technical Terms)
True
Cleanout size, but not cleanout spacing can be shown on a stack elevation.
4", Fixture
Cleanouts installed in drainage piping of a trade size of _________ or smaller shall be the same size as the ___________ it serves.
Galvanized
Coated with a protective layer of zinc
C F
Converting to ___ (from ___) 'C = ('F-32) x 5 / 9
F C
Converting to ___ (from ___) 'F= 'C x 9 / 5 + 32
Pressure
D.W.V. fittings must never be used as ___________ fittings because D.W.V. fittings have much thinner walls and are obviously not designed to withstand high pressure.
Circumferential
Denoting or relating to the circumference of a curved geometric figure
Air flows into the fresh air inlet and exits out the vent terminal on the roof
Describe the air flow through our plumbing system if a building trap is installed on the sanitary building drain?
Fitting and End Cleanouts
Designed for installation in a fitting or at the end of a horizontal branch or similar pipe. Intended for cleaning only downstream from the cleanout.
Westmount
Designed for use in exposed locations, as it has a more finished appearance than the A.B. cleanout. Consists of a brass plug screwed into a brass or cast-iron ferrule. The plug is available with a raised or countersunk head.
In-Line (ABS-PVC)
Designed for use with ABS or PVC plastic drainage pipe, similar in appearance to copper cleanouts. It consists of a plastic screwed plug attached to a plastic body.
1
Does plastic pipe requires more or less horizontal supports than thicker steel pipe? 1. Yes 2. No
Drainage Piping
Don't allow grease, oil or other congealing substances to enter what?
Water Closets
Don't allow toys, diapers or other insoluble objects to be flushed down what?
1"
Drains from coolers and walk-in freezers should be hooked up to a funnel floor drain indirectly through an air-break and the vertical distance should be a minimum of ______
pressure increases - boiling point increases
Effects of pressure on the boiling point of water ________
Pressure, drainage
Either ___________ fittings or __________ fittings are generally accepted in vent piping, although pressure fittings are usually heavier and, therefore, more expensive than drainage fittings, making their use in vent piping cost prohibitive. (Answer Example: "ANSWERONE, ANSWER TWO")
Main
Every building must have a __________ stack.
rain water leaders
Every soil and waste stack, along with all ________ ______________ ___________ and must have cleanout installed at the base of the stack.
Close, enters, building
Every storm and sanitary building drain shall be provided with a clean out located As ______________ as possible where the building drain ________ the ______________ (Answer Example: "ANSWERONE, ANSWERTWO")
Sanitary Plumbing, Sanitary, Seal Primer
Floor drains are always considered to be __________ __________ fixtures, this means all floor drains must connect to a __________ drainage piping, be equipped with a trap and a __________________.
2
Floor drains located below ground shall have an outlet with atrade size of not less than___ inch.
a
Floor drains that are seldom used would likely lose their trap seals due to evaporation, oscillation, capillary, attraction, back pressure and back siphonage. a. True b. False
2
Floor drains that are suspended shall have an outlet with a trade size of not less than ___ inch.
Fixture Drain, Diameter
Floor drains which, when located below ground, do not require an additional vent if the ta fall of the ___________ __________ does not exceed the ___________ of the fixture drain. (Answer Example: ANSWERONE, ANSWERTWO)
Same floor Level, Food, Organic
Flor drains may be gang trapped when they are located on the ______________________, and cannot receive _________ or other __________ matter. (Answer Example: ANSWERONE, ANSWERTWO, ANSWERTHREE)
Back Water Valve
For backflow protection on combined systems, a _______ _______ _____________ must be installed
False
Foundation drain and downspout connections cannot be shown on a stack elevation.
0
Freeze Point of Water: Answer for Degrees Celsius
B
If a cleanout plug is required on a p-trap, what is the minimum size of the cleanout plug? a. 1/2" b. 3/4" c. 1 d. Same Size as Trap
Top View
From which view describes a drain plan?
55-57
Ground Water Temperature: Answer for Degrees Fahrenheit
Polypropylene
Has a high impact strength, temperature resistance, and chemical resistance, is often used in industrial drainage, laboratory drainage, and industrial process piping applications.
Cast Iron
Has a superior nois supression, which significanly reduces noise caused by fluid transmission, expansion and contraction.
TY, 90
Horizontal drainage piping should connect to vertical drainage piping with a _________ or a Y or a ________ degree elbow.
Symmetrical Fittings
How are the 'Ontario' and Toronto fttings discussed in our workbook are described in our code book? What is their name?
D
How are the 'Ontario' and Toronto fttings discussed in our workbook are described in our code book? What is their name? a. Quality Fittings b. Qualitative Fittings c. Symmetry Fittings d. Symmetrical Fittings
1.2 M (4')
How far apart should horizontal pipe supports be for ABS pipe?
2
How is the outside diameter of a steel pipe affected as the wall thickness (schedule) of the pipe is increased? 1. The inside diameter is going to affect the outside diameter. 2. the inside diameter is not going to affect the outside diameter.
a
How is the wall thickness of a 2" black steel affected as the weight of the steel pipe increases? (a) The inside of the pipe is decreased (b) The inside of the pipe is increased (c) The outside of the pipe is increased (d) The outside of the pipe is decreased
1
How many Kg. in a litre of water
6.5
How many imperial gallons in a cubic foot of water (Imperial)?
3.8
How many litres of water in a U.S. gallon?
4.54
How many litres of water in an imperial gallon?
60 pounds torque
How many pounds of torque are required on the standard MJ clamp to properly fit a cast iron soil pipe joint?
Hubless
Hub and spigot cast iron pipe is still produced today, but seldom used. What is the term of the cast iron connection known if it is not hub and spigot?
Trap Seal Primer
Hub drains and funnel floor drains also require a _____________________ connection.
Inside Diameter
I.D (Technical Terms)
Iron Pipe Size
I.P.S (A trade term used to compare all other pipe threads to iron pipe threads) (Technical Terms)
1
IF CSA approved, can PVC pipe be used for water supply? 1. Yes 2. No
accessible
INSTALLATION POINTS: A cleanout shall be installed so as to be readily "_____________" as defined by Part 7 O.B.C.
Drain cleaning purposes
INSTALLATION POINTS: Cleanouts and access covers shall be located so that the openings are readily accessible for what?
Caulked Joints
Ideal for joining hub and spigot where a degree of rigidity is required. It is especially convenient where a slight ground movement may be encountered or where piping is suspended within a building.
Normally Closed (NC)
If a backwater valve is required on the Sanitary Building Drain, which of the following types must be installed?
3"
If a beer cooler has an indirect waste of 2", the size of the hub drain should be _________
4"
If a building trap is installed on the Sanitary Building Drain, what is the size of the fresh air inlet vent?
Within 4 feet on the upstream side of the trap
If a building trap is installed on the Sanitary Building Drain, where is the fresh air inlet vent located?
In the fresh air inlet and out the vent terminal
If a building trap is installed, which way does the air flow though our DWW system for a standard home?
Directly over the upstream side of the trap
If a building trap with hand-hole clean out is required, where does the cleanout connect to the trap?
3/4"
If a cleanout plug is required on a p-trap, what is the minimum size of the cleanout plug?
1"
If proper thread engagement is achieved, approximately how many threads should be exposed on a 1/2" steel pipe joint?
Float
If the specific gravity of vodka is 0.916, will it sink or float when mixed with water at room temperature?
2 1/2
If we accomplish proper thread engagement on a ½" steel pipe and fitting, approx. how many threads should be visible outside of the fitting?
Smoother
Is ABS pipe smoother or rougher on the inside that most steel pipes?
Drainage
Is ABS pipe used more widely for potable water distribution or drainage?
Inside Diameter
Know the following acronym: I.D
Iron Pipe Size
Know the following acronym: I.P.S
Nominal Pipe Size
Know the following acronym: N.P.S
Outside Diameter
Know the following acronym: O.D
Cleanout
Know the following acronyms: CO
Rain Water Leader
Know the following acronyms: RWL
Soil Stack
Know the following acronyms: SS
Trap Seal Primer
Know the following acronyms: TSP
Waste Stack
Know the following acronyms: WS
Yellow
List the color code for the following weights of copper: DWV
Green
List the color code for the following weights of copper: K
Blue
List the color code for the following weights of copper: L
True
Location of vent terminals can be shown on a stack elevation.
Male Iron Pipe
M.I.P (Technical Terms)
90, 30
MANHOLES: Building sewers of eight inches through twenty-four inches in size and 30 meter (98 ft 5 in) or more in length shall be provided with access through manholes spaced not more than ___ meters (295 feet 3 inches) apart and no manhole shall be more than ___ meters (98 feet 5 inches) downstream from a building drain. (Answer Example: ANSWERONE, ANSWERTWO)
150, 30
MANHOLES: Sewer piping of a size larger than twenty-four inches shall have manholes spaced at intervals of not more than ___ meters (492 feet 2 inches) and no manhole shall be more than ___ meters (98 feet 5 inches) downstream of a building drain. (Answer Example: ANSWERONE, ANSWERTWO)
Manholes
MANHOLES: There shall be no change in slope or direction of any section of sewer between __________.
c
MANHOLES: Where a manhole is installed within a building or if an addition to the building encloses an existing manhole, the manhole: a) Shall have a sealed cover so as to be airtight. b) Shall be vented independently to outside air with a vent having a minimum inside diameter of 3 inches and extending at least 300 millimeters (1 foot) above grade. See Figure 2.16-21. c) All of the above
Tubular P Trap
MANHOLES: __________ ____ ______ with union connections commonly used at lavatory basons. May only be used in an accessible location
As-built drawings
Man made drawings that represent the actual location of mechanical piping
e
Manholes must be installed in building sewers at all ____________, changes in _________, __________ or _____________ a. Junctions b. Grade c. Size d. Alignment
Thread Taper
Necessary for pipe to tighten into fitting (Technical Terms)
Outside Diameter
O.D. (Technical Terms)
Corrosive
Of Corrosive and non-corrosive flux, which one is used in the soldering process?
A
Of the 3 grades of steel pipe, which is the most Ductile? A, B or C.
Separate
Of the 3 types of drainage systems used by municipalities, which is the most common used today?
K
Of the different weights of copper listed below, which is the heaviest/thickest?
1/2" and 3/4"
Of the following steel pipe sizes, which ones have the same threads per inch which means they have the same die chasers?
6
Of the pipe sizes listed below, circle the ones that have the same threads per inch? 1. 1/8" and ¼" 2. ¼" and ½" 3. ½" and ¾" 4. ¾" and 1" 5. 1 and 2 6. 3 and 4
45
Once a double Y is installed on a ___ angle, the branches are turned slightly upward and this installation is, therefore, quite acceptable.
Snap Cutters
One of the most common methods of cutting cast iron pipe is to use a __________.
Gasket
Other than gluing PVC pipe, what other joining method is mentioned in our workbook?
Threading
Other than the MJ clamp or 'prepper coupler' whatis/was acommon way of joining 2 dissimilar pipes?
Threaded
Other than the rubber MJ clamp, what is the most common way of connecting 2 dissimilar materials?
Pounds Per Square Inch
P.S.I (Technical Terms)
Cross-linked polyethylene
PEX is the most common water piping used in residential applications today. What is the acronym PEX stand for?
False
Proper pipe slope should be shown on a stack elevation.
Drawn Over Mandrel Tubing
Refers to coiled rolled electric welding tubing that goes through an additional process. Just as it sounds, the tubing is electrically welded, then it is drawn over a mandrel on the inside diameter of the tube and a die on the outside diameter. The drawing process ensures tighter tolerances and a smoother finish, requiring less machining.
Nominal Pipe Size
Refers to pipe in non-specific terms and identifies the diameter of the whole with a non-dimensional number.
4
SIZING REQUIREMENTS: Cleanouts connected to piping having a trade size larger than 4 inches shall not be smaller than ___ inches.
4
SIZING REQUIREMENTS: Cleanouts connected to piping having a trade size of ___ inches or less, shall be the same size as the pipe. This is to ensure that the cleanout opening will be large enough to permit the entrance of a cleaning apparatus into piping of each trade size.
Building
Separate drainage system do not use ___________ traps at all.
green
State the colour code for the following: Dry Vent
Blue
State the colour code for the following: Floor Drain Primer
blue
State the colour code for the following: Storm Drain
red
State the colour code for the following: Waste Pipe
green (or red)
State the colour code for the following: Wet Vent
Inside Diameter
Steel pipe sizes up to 12" is known for the approximate inside or outside diameter?
B
What does PDC stand for? a. Public Drain Connector b. Private Drain Connection c. Public Drain Cleanout d. Private Drain Cleanout
Municipality
The ____________ will indicate if a building trap will have to be installed while the plumbing code indicates where and how a building trap will be installed.
Nominal Diameter
The accepted minimum turning radius of a 90°elbow to be used in drainage piping must be at least equal to the ____________ _____________ of the fitting as taken along the fitting centre line.
Thread Angle
The angle at which the threads are cut (60 degrees) (Technical Terms)
Backwater Valve
The appurtenance installed to protectagainst backflow on the storm system is called?
False
The building drain and al horizontal branches should be drawn with a stack elevation.
Inside, Outside
The building trap may be located either ___________ the building, or ___________ the building.
a
The capacity of a hub drain and a funnel floor drain must be equal to the waste being discharged into it. If an indirect waste of a coffee un, ice-cream scoop, ice-making machine, soft drink tray, and a hot water tank safety valve can discharge 14 gallons per minute, what will be the size of the receiving trap or hub drain? a. 14 / 6.25 = 2.24 F.U. therefore a 3" receiving trap or hub drain would be required b. 14 / 6.25 = 2.24 F.U. therefore a 4" receiving trap or hub drain would be required c. 14 / 6.25 = 2.24 F.U. therefore a 5" receiving trap or hub drain would be required d. 14 / 6.25 = 2.24 F.U. therefore a 2" receiving trap or hub drain would be required
length of time
The choice a plumber makes in selecting a vacuum breaker or a pressure vacuum breaker is determined by the ________________ the device will be in operation.
Drinking Fountain
The discharge from a _____________ ____________ may be used to provide a supply of water to a floor drain.
Diameter
The distance from one point on a circle through the center to another point in a circle. It is also the longest distance across the circle.
main vent
The drawing of a stack elevation should start with the __________ _________
Cleanout
The first connection to the incoming building drain should be the ____________
Vertically
The fittings shown in Figure 2 .17-10 and Figure 2 .17-12 allow simultaneous discharge of the branches and yet prevent the waste from crossing over into the other branch. These two fittings must only be used ___________ .
1.2
The fresh air inlet must connect upstream from the building trap no further than _______ meters
air
The fresh air inlet, installed in conjunction with the building trap permits _____ to enter the building drain and to exit the
solid, green, vent
The main stack must be drawn as a _________ line, and colour _________ where it becomes the stack _________.
One
The mechanical joint can be assembled with the use of _____ tool(s).
4"
The minimum diameter of a storm building drain is
12 hours, 12 years
The minimum length of time of continuous operation is ______________ and ______________ of the year, if a pressure vacuum breaker is selected for mechanical equipment cooling lines to prime traps. (Answer Example: ANSWERONE, ANSWERTWO)
4
The minimum size for a fresh air inlet is _____ inches.
3/8
The minimum size for a primer tube is _____ inch, inside diameter size
4"
The minimum size of a funnel floor drain is _______
1 1/4"
The minimum size of a hub drain is ________
4
The minimum size ofan area drain, a windowwll pipe outlet, and a subsoil drainage branch is _______?
rubber
The most common joining method used today for cast iron pipe and fittings is ___________ couplings.
Aluminum
What does the acronym AL stand for when used in PEX-AL-PEX?
vermin, gases, building
The purpose of a building trap is to prevent ___________ or sewer _______ from passing into the ___________.
d
The purpose of installing a clean-out in a drainage piping is to a. allow the insertion of cleaning apparatus into drainage piping so that any blockages or obstructions may be readily cleared. b. insert cameras for investigation of pipe grade, obstructions, condition of pipes, location of offsets if they can't be tracked as built drawings and locate distances of connections c. allow future access into the system d. all of the above
b
The reason why the backwater needs to be this way in order to act as a cleanout is: a.The gate could be destroyed and the trap seal could be worn out by the cleaning rod b. The gate could be destroyed and the seat could be worn out by the cleaning rod. c. It's for good luck d. It is regulated plumbing practice
the problem or issue with oversizing drainage piping
The sewage water is too shallow and the solids do not float away together and get left behind on imperfect fitting or poorly cut piping joints etc. This is an example of:
Storm Trap
The terminology used to define a trap which is required on a storm drainage system at point of entry into a building is a ______________ _________.
3/4
The trap of a laundry tub would require a clean out with a minimum diameter of ____ inch.
False
The type of material to be used in a plumbing installation should be shown on a stack elevation.
Left-Hand Thread
This thread is cut in the opposite direction and is used on left and right nipples and couplings. A left-hand nipple and coupling may be used in place of a union coupling. The nipples are identified with a colour on the left-hand thread and the couplings usually have four straight bars on the side. (Technical Terms)
Type 2
This type of coupling consists of a heavier, specially designed neoprene sleeve. Two stainless steel gear clamps fit into slots in the sleeve. The increased weight of the sleeve allows for its use without a sheath.
Short
Too _____ a pipe thread does not allow enough thread to enter the fitting . This prevents the proper use of all threads in the fitting and can result in a weakened connection and possible leakage.
Long
Too _____ of pipe thread allows the pipe to travel too far into the fitting. Correct thread engagement of the taper is not made since most of the tapered threads remain outside the fitting.
d
What do Lavatories, Laundry tubs, and Kitchen Sinks must have? a. A bottom outlet plug b. Cleanup c. Union P-Trap that can be taken apart d. All of the above
4
Water is Densest (heaviest) at: ___________ Answer for Degrees Celsius
False
Water pipe risers should be shown on a stack elevation.
True
Water pipes are shown on ariser diagram.
potable, organic
Water used to prime a floor drain does not have to be __________, but should have no __________ matter in it. (Answer Example: ANSWERONE, ANSWERTWO)
b
What are non-corrosive fluxes typically used for? (a) Soldering metals other than copper (b) Applied to metal to protect the metal form oxidization (c) Soldering with hard solders (d) Act as lubricant for threaded pipe and fttings
Thermosetting and Thermoplastic
What are the 2 categories ofplastic pipes used for our piping systems?
Tin/Antimony
What are the 2 metals typically found in today's lead-free solder thatis used in water distribution piping?
Butt-weld and seamless
What are the 2 of the 3 common types of steel wall construction when manufacturing steel pipe?
Corrosive, Non-corrosive
What are the 2 types of flux discussed in our workbook
Thermosetting, Thermoplastic
What are the 2 types of plastics mentioned in the workbook? (example: Answer, Answer)
Hard, Soft
What are the 2 types of solders mentioned in the workbook?
Hard drawn (or soft annealed)
What are the 2 ways copper pipe is manufactured?
Lavatory, kitchen sink, laundry sink
What are the 3 fixtures that require the trap to be either a cleanout on the trap or a union type trap that can be dismantled?
Seamless, Lap Weld, Butt Weld
What are the 3 terms used for the manufacturing of steel pipe? How is the pipe produced/welded etc?
B
What are the colors used for sanitary, venting and storm toidentify piping on a drain plan? a. Orange, red, blue b. Red, green, blue c. Red, yellow, blue d. Red, blue, grey
Red, green, blue
What are the colours used for sanitary, venting and storm to identify piping on a drain plan?
Normally open, (NO) and Normally Closed (NC)
What are the names of the 2 types of backwater valves that operate by gravity?
3" min vertical, 2" max horizontal
What are the restrictions mentioned in our workbook and codebook about double TY fitting on the vertical being used to accept drainage?
Separate, Combined and Sem-combined
What are the three common types of Sewer Drainage systems that exist in Ontario?
Public Drain Connection
What does PDC stand for?
Cleanout
What is this part called from Figure 2.16-10 in the Basic Plumbing Workbook.
Hinged Access Cover
What is this part called from Figure 2.16-10 in the Basic Plumbing Workbook.
Drains and Vents
What is type DWV copper typically used for?
2
What should be done to a PVC pipe and fitting before the glue is applied? 1. Submerge with mineral oil and put into fitting 2. take a cleaner and separate from the pipe and fitting sockets any dirt, oil, or grease 4. There is nothing to do before
Rod Coupler
What type of fastener is shown below?
c
What will be the result of a threaded steel connection if the number of threads on the pipe are excessively short? (a) The pipe will not thread in at all (b) The pipe will never tighten into the fitting (c) There will not be proper thread engagement and may cause a leak (d) As long as you use plenty of pipe thread sealant, everything will work properly
Mechanical Join Couplings
When 2 cast iron pipes are connected with a rubber seal and stainless steel clamps, what is the connection called?
True
When 2 pipes cross each other on a drain plan and are not connected, what must be done? (T/F) The lower piping must be a broken line where it crosses the upper piping
73ºF
When ABS pipe is tested for strength etc, at what temperature is the pipe tested at?
vented properly
When a building trap is not installed, the public sanitary sewer is ___________ _____________.
sounded
When checking a cast iron pipe or fittings for cracks, the pipe and fitting should be examined _________ and tapped gently with a Ball Peen Hammer.
Ball Peen Hammer
When checking a cast iron pipe or fittings for cracks, the pipe and fitting should be examined sounded and tapped gently with a ___________.
Level Rim
When connecting a primer tube to a floor drain, a potential cross-connection occurs where the primer tube connects to the floor drain below the flood _________ _______ of the floor drain.
Sealed
When constructing a caulked joint, the function of the oakum is to make the joint _________
2/3 of the material
When drilling a hole in a load bearing wall, how much of the wall must remain intact?
40 mm (1 5/8")
When drilling a hole in a non-load bearing wall, how much of the wall must remain intact?
Same Floor
When gange trapping floor drains, they must be on the _________ ________ level
1"
When there is a potential for cross contamination between drinking water and drain piping, what is the minimum vertical distance of an 'air-break' if used?
Riser Clamp
When using ariser fitting when installing vertical cast iron pipe through a sleevel hole, what is the name ofthe support used under the sleeve.
12 months of the year
When using mechanical equipment to prime a floor drain, t must be determined that the equipment will be in operation ______________
top
Where a "TY"is installed to connect an individual vent, the rounded weir should be on the ______ side of the fitting.
90, elbows
Where a fresh air inlet terminates above ground, it should be protected from blockage by installing two ___________ degree ____________ down to protect against the elements and a bird screen installed to protect against vermin.
size, height, above
Where a vent extends through the roo, the information that must be included is the ______ of the flashing and the ________ of the terminal ________ the roof
C
Where can a short radius 90' elbow be used in our drainage system? a. On the horizontal b. At the base of a stack where it changes from vertical to horizontal c. At the top of a stack where it changes from horizontal to vertical d. lt can never be used on the drainage system
Combined system connects upstream of the property line and semi-combined connects downstream of the property line
Where is the connection between the storm and sanitary drainage piping in a combined system compared to a semi-combined system?
150
Where manholes are required in a building storm sewer with a trade size of 30 inches, the distance between manholes shall not exceed ______ meters.
f
Which Answer is: 1 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
p
Which Answer is: 10 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. (Earlier Option) n. W.S o. W.P p. F.D. (Later Option) q. C.O
e
Which Answer is: 11 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
h
Which Answer is: 12 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
q
Which Answer is: 13 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
k
Which Answer is: 14 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
i
Which Answer is: 15 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
j
Which Answer is: 16 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
l
Which Answer is: 17 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
a
Which Answer is: 2 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
g
Which Answer is: 3 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
m
Which Answer is: 4 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
b
Which Answer is: 5 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
d
Which Answer is: 6 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
n
Which Answer is: 7 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
c
Which Answer is: 8 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
o
Which Answer is: 9 a. WYE CONNECTION" b. DRAW AS MANY LINES AS POSSIBLE, PARALLEL WITH THE BUILDING WALLS c. WYE AND 45' CONNECTION d. BY CONVENTION, THE TRAP IS DRAWN IN ELEVATION VIEW e. BREAK LINES WHERE THEY CROSS ANOTHER f. AVOID THE USE OF LONG DRAINAGE PIPES 45' TO THE MAIN DRAIN g. DRAW THE FLOOR DRAIN TRAP TO THE CENTER OF THE FLOOR DRAIN INLET h. BY CONVENTION, THE CLEANOUT IS SHOWN IN ELEVATION VIEW i. Property Line j. Municipal Sewer k. Private Property l. Public Property m. F.D. n. W.S o. W.P p. F.D. q. C.O
Type 1
Which of the following MJ clamps incorporates a stainless steel sleeve/ sheath around the rubber coupling?
a
Which of the following Mechanical Joint type couplings would work properly when 2 manufactured glass pipes are connected together that have never been cut? (a) Beaded end to beaded end MJ coupling (b) Plain end to plain end MJ coupling (c) Beaded end to plain end MJ coupling (d) Type 2 MJ coupling
Laundry Tub
Which of the following fixtures is not permitted to be gang-trapped?
Initial cost of all the piping
Which of the following is a disadvantage of a separate system?
2
Which of the following is an advantage over plastic when using cast iron pipe for drainage?(circle) 1. Much lighter to work with 2. Much quieter when water is running through it 3. Easier to cut and work with 4. Easier to support horizontally
Cast Iron
Which of the following materials for pipe have the best pierce test strength?
1"
Which of the following pipe sizes have a thread count of 11 1/2 "threads per inch?
D
Which of the following responses below can cause a blockage in a drainage system? a. Oversized Piping b. Improper Pipe joint engagement c. Improper Slope d. All of the above
c
Which of the following statements is true when discussing ABS pipe? (a) Itis very heavy in weight which makes it more labour intensive to install (b) lt is well suited for fire rated installation applications (c) lt is most commonly used for residential plumbing applications (d) lt has a low co-efficient of expansion
2
Which one is most commonly used for plastic piping in the plumbing industry? 1. Thermosetting, 2. Thermoplastic
80
Which steel wall on the pipe is thicker? Schedule 40 or Schedule 80?
Corrosive Flux
Which type of flux is used for soldering copper pipes and fittings
Side or Front View
Which view best describes the piping shown on a plumbing stack elevation?
Clockwise
Which way do you turn a pipe to tighten a standard thread into any fitting? Clockwise or Counter-clockwise?
Outside
Which would be larger? The inside or outside diameter of steel the pipe?
5
Why is Polyethylene more flexible than CPVC and PVC? 1. Because of the different chemical processes it takes to create PE 2. It is given a special coating after the formation which gives it its flexibility 3. PE is made without chlorine, and is derived completely from ethylene, which gives it its flexibility. 4. It is not more flexible. 5. 1 and 3
B
Why is there little to no smell from the manhole sewers on the streets? a. The lids are sealed b. The lids are sealed The air typically flows into the manhole c. The sewer is always cooler than the streets and therefore the odor will not rise d. Municipalities create mechanical negative pressures on public sewers
Cast Iron
_____ _____, copper and steel pipe have long histories of being used for drains, wastes, vents, waterlines, and process plumbing.
Plastic
________ will not rust or corrode in their environment or as a result of the substances they carry. There is a multitude of corrosive materials used in the industry
Carbon Steel
_________ ________ pipe is available in either Grade A, B, (and in a few cases) C.
Correct
__________ Orientation of the Branches if 2 Y Fittings are used in Horizontal Drainage Piping
Incorrect
__________ Orientation of the Branches of a Double Y if it is installed in Horizontal Drainage Piping
Galvanized
___________ Steel Pipe may be used in a drainage system or venting system above ground inside a building.
Symmetrical
______________ fittings as described in Code are now acceptable and approved fittings. They were previously referred to as Ontario and Toronto fittings. The use of these fittings is accepted because all wastes tie in above the horizontal centre line of the water closet.
Cleanout
A device having an airtight, removable, and replaceable cover or plug and is designed to be installed in a pipeline or in a fitting.
In-line (copper)
Designed for use with a copper drainage tube. Consists of brass screwed plug or circular bolted cover attached to a cast copper body.
Barret
Designed for use with bell and spigot cast-iron piping. It consists of a rectangular cast-iron cover bolted to a cast-iron body.
In-Line (M-J Cast Iron)
Designed for use with hubless cast-iron soil pipe. It consists of a circular cast-iron cover bolted to a cast-iron body.
A.B (Malcolm)
Designed originally for installation with a cast-iron hub. Consists of a cast-iron cover bolted to a cast-iron ferrule. Has been adapted for use with hubless soil pipe and with 'O' ring joints for use with asbestos cement.
g
Faulty joints and connections are usually the results of: a. Uneven cutting of the pipe; b. Unreamed pipe; c. Not "bottoming" the pipe in a fitting; d. Poor alignment; e. Allowing oakum, solder, cement, or other jointing material to protrude into the pipe; f. Improper thread engagement. g. all of the above
Ground Settlement
INSTALLATION POINTS: Cleanouts installed in exterior drains should be provided with an independently attached access cover to prevent possible pipe damage due to what?
Access Door
INSTALLATION POINTS: Cleanouts installed in or behind a wall should be provided with an ________ ________ of sufficient size so that sewer cables may be readily inserted into the piping.
floor movement
INSTALLATION POINTS: Cleanouts installed in or under floors should be provided with an independently attached access cover to prevent stress from being placed on the piping due to what? The cover should be sufficiently strong to withstand expected traffic.
e
LOCATION REQUIREMENTS: A screw plug's diameter does not apply to: a. Fixtures such as water closets, pedestal urinals, bedpan washers, etc., which have trap dips that are readily accessible for cleaning b. A trap of which the bottom part is removable; (see Figures 2.16-14and 2.16-15) c. A bathtub trap, shower trap or bidet trap (see Figure 2.16-16) d. A floor drain e. All of the above
Waste Pipe
LOCATION REQUIREMENTS: Additional cleanouts shall be provided so that the developed length of any section of _____________ between cleanouts located downstream of a sink does not exceed meters (19ft 8 in).
4, 30
LOCATION REQUIREMENTS: Cleanouts installed in horizontal drainage piping of a trade size larger than ___ inches shall be located at intervals not exceeding ___ meters. (Answer Example: ANSWERONE, ANSWERTWO)
4, 15
LOCATION REQUIREMENTS: Cleanouts installed in horizontal drainage piping of a trade size of ___ inches or less shall be located at intervals not exceeding ___ meters. (Answer Example: ANSWERONE, ANSWERTWO)
one
LOCATION REQUIREMENTS: Cleanouts that allow rodding in ____ direction(s), shall be installed to permit rodding in the direction of flow.
Sanitary Building Drain
The part of gravity drainage piping that is horizontal and receives the discharge from all soil and waste stacks within a building, as well as from all horizontal branches and waste pipes connected directly to it and conveys the discharge to the building sewer.
a
What is this? a. An Adjustable Cleanout for finished areas. b. A Plug Cleanout Popular for use with urinals c. An Access Door provided for a cleanout located in a partition wall
b
What is this? a. An Adjustable Cleanout for finished areas. b. A Plug Cleanout Popular for use with urinals c. An Access Door provided for a cleanout located in a partition wall
c
What is this? a. An Adjustable Cleanout for finished areas. b. A Plug Cleanout Popular for use with urinals c. An Access Door provided for a cleanout located in a partition wall
Concrete
What material is used to independently support the access cover?
Too little grading
When related to improper grading, this mistake results in a sluggish flow, allowing the solids to pile up along the entire pipe run. This fault often results in the complete blockage of a horizontal drain.
45, 40
LOCATION REQUIREMENTS: Every waste pipe serving a wall-hung urinal shall be provided with a cleanout that is extended above the flood level of the fixture and to the face of a wall where it is readily accessible. No angle greater than ___° fitting shall be installed from the branch to the cleanout outlet. Good engineering practice should dictate the height of the cleanout outlet in order to prevent possible injuries during rodding out of the line. A maximum of ___ inches above the finished floor is recommended (Answer Example: ANSWERONE, ANSWERTWO)
150
LOCATION REQUIREMENTS: Fixtures in health care facilities, mortuaries, operating tables, incinerators, laboratories, urinals, and similar occupancies where contamination from body fluids is likely, shall have required cleanouts located a minimum of ___ mm above the flood level rim of the fixture being served by the cleanout.
Running Trap, Hand-hole
LOCATION REQUIREMENTS: No _________________ shall be installed unless provided with an accessible ______________on the inlet side of the trap for cleaning purposes. Where the trap is too small to accommodate an actual (SAME ANSWER AS ANSWERTWO), a cleanout shall be provided for cleaning purposes. (Answer Example: ANSWERONE, ANSWERTWO)
Building, Inlet
LOCATION REQUIREMENTS: Where a building trap is installed in a _________ drain, the trap shall be provided with a cleanout on the _______ side. (Answer Example: ANSWERONE, ANSWERTWO)
Horizontal, Leader
LOCATION REQUIREMENTS: A cleanout shall be installed as close as is practical to the foot of each soil stack, waste stack, and rainwater leader. The main purpose of these cleanouts is to permit the cleaning of the ____________ drainage piping connecting the stack or ___________ of the building drain. (Answer Example: ANSWERONE, ANSWERTWO)
Drop-type
MANHOLES: Where it is necessary to change the elevation of a sewer or where there is a junction of two or more sewers that are at different elevations, a '_________' manhole shall be used to make the elevation change.
Union Cleanout
MANHOLES: A ________ _________ commonly used at kitchen sinks, and this type connection allows bottom part of the trap to be removed.
Storm building sewer
Means a building sewer that conveys storm sewage to a place of disposal and commences 1,000 mm (3f 3in) from the building.
Storm Drainage System
Means a drainage system that conveys storm sewage.
Plumbing Appliance
Means a receptacle or equipment that receives or collects water, liquids or sewage and discharge water liquid or sewage directly or indirectly to a plumbing system.
Soil Pipe
Means a sanitary drainage pipe that carries the discharge of a sanitary unit with or without the discharge from any other fixture.
Basement
Means a storey of a building located below the first storey.
Plumbing System
Means a system of connected piping fitings, valves, equipment, fixtures and appurtenances contained in plumbing.
Stack Vent
Means a vent pipe that connects the top ofa soil or waste stack to a header or open air and "stack vented" has a corresponding meaning Stack venting when used with reference to fixtures means an arrangement such that the connections of the drainage piping from the stack vented fixtures to the stack provide venting to the fixture traps so that no additional vent pipe is required.
Branch Vent
Means a vent pipe that is connected at its lower end to the junction of 2 or more vent pipes and is connected at its upper end either to a stack vent, vent stack or header, oris terminated in open air.
Vent Stack
Means a vent pipe that is connected at its upper end to a header or is terminated in open air and that is used to limit pressure differential in a soil or waste stack.
Soil Stack
Means a vertical soil pipe that passes through one or more storey and includes any offset that is part of the stack
Waste Stack
Means a vertical waste pipe that passes through one or more storey and includes any offset that is part of the stack that conducts liquid waste from fixtures other than sanitary units.
Venting system
Means an assembly of pipes and fittings that connect a drainage system with open air for circulation of air and the protection of trap seals in the drainage system.
Drainage System
Means an assembly of pipes fittings, fixtures and appurtenances on the property that is used to convey sewage and clear water waste to a main sewer or a private sewage disposal system, and includes a private sewer but does not include subsoil drainage piping.
Backwater Valve
Means check valve designed for use in a gravity drainage system.
Sanitary building sewer
Means that part of drainage piping that is outside a building, receives discharge from the sanitary building drain and conveys the discharge to a public sewer or to a private disposal area. Since it conveys the sewage from the entire building, special consideration should be given to proper installation and provision for maintenance, so as not to interrupt service from the building.
Trap Arm
Means that portion of a fixture drain between the trap weir ant the vent pipe fitting. Vent pipe means a pipe that is part ofa venting system.
Developed Length
Means the length along the centre line of the pipe and fittings.
Building Drain
Means the lowest horizontal piping, including any vertical offset, that conducts sewage, clear water waste or storm water by gravity to a building sewer.
Main Sewer
Means the municipal or public sewer, including branches extended to the property line. The figure below shows the typical layout of a building sewer and a main sewer in plan view.
Building Height
Means the number of storeys contained between the roof and the floor of the first storey.
Fixture Drain
Means the pipe that connects a trap serving a fixture to another part of a drainage system.
Flood Level Rim
Means the top edge at which water can overflow from a fixture or device.
Vertical leg
Means the vertical portion of a fixture drain and includes the portion of a drain from the outlet of a water closet bowl to the point where the connecting piping changes to horizontal.
Accessible
Means when applied to a fixture, connection, plumbing appliance, valve, cleanout or equipment, have access there to but wich first may require the removal of an access panel, door or simlar obstruction without cutting or breaking materials.