Test questions
Stratosphere
-10-30 miles.
What is absolute zero?
-460F
Dial of a pressure gage, when the gage is permanently installed on the high side of a refrigerating system, shall be graduated to_______times the design pressure?
1.2
Refrigeration technician is good for:
10 Tons and up.
If (2) 500 Ohm stats are connected in series, resistance will be:
1000 Ohms
If (2) 500 Ohm resistors are wired in series, total resistance will be:
1000 Ohms.
A1 refrigerants over_______lbs l. Must be discharged to atmosphere
110
522CMR9.0 has adopted for a reference ASHRAE Standard:
15
Recovery cylinder
2 Parts - liquid/ vapor.
Pressure relief valves must discharge into atmosphere at least 15' above ground and_______from windows /ventilation openings.
20
One ton of refrigeration is removal of heat at:
200 BTU/MIN, 12,000 BTU/HR, 288,000 BTU/Day ALL OF THE ABOVE.
A single pole, double pole switch requires:
3 Wires
What is the electrical rating of 1 Watt of energy?
3.4 BTU/HR.
The total amount of refrigerant to be stored in a machinery room:
330 Ibs (ASHRAE) - 300 Ibs (Mass Code).
55. A rule of thumb in A/C is how many CFM/Ton?
400.
49. Liquid refrigerant 22 enters the evaporator at 50.2 PSIG/20 F and leaves at 38 F. It's pressure as it leaves will be:
50.2
Recovery cylinder
80% ONLY!
79. A chilled water pump suction gage reads 10 psig, discharge gage reads 48 psig. What is the head in feet of water the pump is working against?
88 ft. w.g. (1PSIG = 2.31 ft. hd) 38X2.31=88
High pressure controls should not be set higher than________% of the relief valves.
90
Liquid receivers shall not occupy more than_______% at 90 F.
90
Recovery cylinder
DOT approved.
A halide torch is most useful w/ a Freon compressor system to____________
Detect leaks in the piping joints
Oil separator is always inserted in the system in the:
Discharge Line
Clearance volume:
Effects compressor capacity.
Heat is a form of:
Energy
On cooling towers, what causes the condenser water temperature to drop?
Evaporation of the water droplets.
Two basic types of evaporators are:
Flooded & direct expansion feed.
Location of a low side and high side float (top/bottom)?
Flooded evaporator.
The boiling point of a refrigerant is governed by:
A temperature / pressure relationship.
If you have a clogged filter, what does motor do?
Amperage goes up, motor overheats.
The critical temperature of a refrigerant gas occurs when:
Any increase in pressure will not liquefy the gas.
By increasing superheat setting on a TXV will do what to frost line?
Get shorter.
A cascade system is:
Two or more refrigeration circuits (ANSI/ASHRAE P. 3).
How many closing forces operate a thermostatic expansion valve?
Two.
What type of copper tubing is NOT allowed in a refrigerating system?
Type M
Transformers are rated in:
Volt-Amperes.
9. Equation for Ohms Law:
Volts = Amps x Ohms
Formula for power in a resistance
W=VXA
27. Safety requirements are not enforced when_______is the primary refrigerant.
Water
Secondary refrigerants are usually:
Water or brine
Safety requirements are not enforced when________is the primary refrigerant.
Water.
1 degree rise / Ib. of water is known as:
BTU.
Where is a pressure limiting device located?
Between compressor and condenser.
A pressure limiting control shall be located:
Between compressor and stop valve.
Suction line is located:
Between evaporator and compressor.
When you start a walk in box at 90 F, what is designed to prevent liquid slugging to the compressor?
CPR Valve??
Suction valve unloaders afford effective means of:
Capacity control.
In a low pressure chiller, what type of compressor is used?
Centrifugal.
R-407C
Chocolate Brown
The oil separator is located between:
Compressor and Condenser.
A refrigerant turns into a liquid in the:
Condenser.
On a centrifugal compressor, the stationary diffuser vanes are used to:
Convert velocity energy to pressure.
What type of metals is not suited for ammonia systems?
Copper.
1. Thermodynamics is the division of science that deals with:
Heat Energy
A pressure limiting device is:
High Pressure Control
In a walk in cooler, when temperature is lowered, what happens to humidity?
Higher relative humidity
What would be considered an institutional occupancy?
Hospital.
What would be considered a residential occupancy?
Hotel.
Humidity can be sensed with:
Human hair
Which of the following controllers are most sensitive to temperature change?
Immersion Controller
The purpose of the receiver is:
Increase the capacity that a system can hold.
R-22 Chlorodifluromethane
Light Green
R-123 DichlorotrifluorETHANE
Light Grey
R-134a TetrafluoroETHANE
Light/Sky Blue
R-134A
Light/Sky Bluen
Solenoid valve in pumpdown control system would be located in:
Liquid Line
Booster compressors connect to the_______side of the system compressor.
Low Side
When a compressor is used as a booster side of another system, the booster provide that a low pressure stage compressor of the positive displacement type is protected by a compressor is considered on the_______ side of the system, to obtain a low pressure and discharges into the suction pressure relief device.
Low.
A device for measuring small pressure differences is the_________
Manometer.
July 1, 1992
No venting CFC & HCFC.
November 15, 1995 -
No venting HFC's.
Resistance is measured in:
Ohms.
How many forces operate a thermostatic expansion valve?
One opening, Two closing.
How many opening forces operate a thermostatic expansion valve?
One.
R-11 Trichlorofluoromethane
Orange
R-404A
Orange
R-502 R-22+R-115-Charge as vapor or liquid Does na
Orchid
Compressor in which increase pressure achieved by changing internal volume of compressor chamber:
Positive Displacement Compressor Wrong: Non-positive displacement compressor, Compressor pressure limiting device, Pressure imposing device.
In the early 90's, what was the most common refrigerant used?
R-22.
A tachometer is an instrument used to measure:
RPM
21. The refrigerant storage tank that holds a surplus of refrigerant & is located below the condenser is called the:
Receiver
30. Liquid and suction line heat exchangers are used for:
Reducing flash gas (subcools).
Stop valves shall not be permitted between the system and the:
Relief valves
R-410a R-32+R-125 - Charge as liquid only- fracionates
Rose/Pink
If a condenser is on a roof and the temperature is 35 degrees and falling, the capacity will:
Run as designed assuming low ambient controls.
A liquid used for transmission of heat without a change in state or no flash point or flash point above 150F is:
Secondary coolant
Pressure Relief Valves shall be marked w/ data from:
Section VIII Division 1 of the ASME Boiler & Pressure Code
Thermometer placed in discharge air supply. This is reading:
Sensible Heat
If a thermometer is placed at the outlet of the compressor, it will measure only_______ heat.
Sensible.
R-717
Silver
How is the oil pressure adjusted on an ammonia compressor?
Spring Pressure.
Ammonia compressors uses__________to adjust oil pressure.
Spring pressure.
Flusible plugs are marked in:
Temperature
Recovery cylinder
Tested / stamped every 5 years.
Pressure limiting control shall be connected between:
The compressor & stop valve on the discharge side.
ntue0? What would be considered a public assembly occupancy?
Theatre.
When the compressor is below the condenser:
Traps are needed on the discharge line.
R-12 Dichlorodifluromethane
White
Recovery cylinder
yellow top/gray bottom.