Advanced Refrigeration mideterm

अब Quizwiz के साथ अपने होमवर्क और परीक्षाओं को एस करें!

The design box temp for a low temp walk in freezer is between ______ & _______

0 to -20

The saturated amount of sub-cooling for air cooled equipment operating at design conditions using R22 using a TXV is

10

A ___________ evaporator is an evaporator that uses a fan to circulate air across an evaporator coil

Air- medium

A __________ evaporator is a type of air-medium evaporator hat consists of tubing only

Bare tube evaporator

Superheat cannot be determined by taking the difference between the temperatures at the inlet and outlet of the evaporator, explain.

Because of the pressure drop in the evaporator coil, you will get erratic readings

A _________________ system is piping that is used to transfer heat either to or from he earth

Geothermal ground loop

A _________ system is a water system that uses the temperature of the earth to heat or coil the water loop of a building

Geothermal ground loop system

__________ is the most common material used for backfill in geothermal systems

Grout

What is the state of the refrigerant in the liquid line entering the metering device

High pressure, high temp, sub-cooled liquid

A _________ is a device that adds moisture to air by causing water to evaporate

Humidifier

A low temp walk in freezer is operating normally at 0 degrees. The saturated evaporator temp should be ___________

-15

What are 4 ways to check for refrigeration shortage in a system without a sight glass in the liquid line

1) check for high superheat & low sub-cooling 2) check system amperage 3) system operates for longer periods of time between shutdowns 4) low suction pressure & low discharge pressure

What 3 locations can be used to obtain the suction pressure

1) external equalizer line 2) suction line 3) suction valve on compressor

List items to be checked when the superheat is abnormally high

1) lost bulb charge 2) ice,dirt or wax 3) superheat spring set too high 4) excessive pressure drop through evaporator 5) low on charge 6) liquid line restriction 7) undersized compressor 8) undersized TXV

Which check points are to be checked is superheat is found to be abnormally low

1) overcharged 2) lack of airflow 3) overfeeding TXV 4) valve seat leaking

The 5 major requirements for comfort are _____,______,______,______,_______

1) proper temperature 2) humidity 3) circulation 4) filtration 5) ventilation

List 4 steps required to determine superheat

1) take suction line temp 2) get bulb temp 3) convert bulb temp to saturated suction temp 4) difference between saturated suction temp and line temp is superheat

How should a check be made for a lost charge in the remote bulb

1) turn off system 2) disconnect remote bulb 3) place bulb in bucket of ice water 4) start up system 5) remove bulb from bucket and place in hand, if suction pressure increases rapidly bulb charge is ok

Name three special devices which can be used for sub cooling when the system has excessive vertical lift in the liquid line

1) water coils 2) Separate heat exchanger 3) Suction - liquid heat exchanger

Suction superheat at the evaporator outlet for a low temp walk in freezer should be between

1-5

The design temperature rise for a tester cooled condenser is

10 degrees

A water cooled unit using recirculating water operating a design conditions will have a saturated condensing temp of

105

A high efficiency condensing unit operating at design conditions using R22 will have a saturated condensing temp of

120

A standard efficiency condensing unit operating at design conditions using R22 will have a saturated condensing temp of

130

Standard efficiency air handling equipment operating at design conditions will have an air side temp difference across the evaporator of

16-20 (18)

A comfort cooling condensing unit operating normally using R22 should have a superheat value 18" from the compressor of _______

18 degrees

Medium-temperature applications with coil temps renting from ______________

20-40 degrees F

A medium temp walk in cooler is operating normally at 38 degrees. The saturated evaporator temp should be ___________

23 degrees F

Recent studies show that night setback of 2 degrees F reduces the overall efficiency of a geothermal heat pump system by ________%

25%

The design box temp range for a medium temp walk-in cooler is between ________ & _________

35 & 45

Design air handler air flow for comfort cooling is between _______&_______

350 & 450

Air velocity of _______ FPM in building spaces is considered ideal for comfort

40 FPM

Comfort is typically attained at normal cooling and heating temps with a relative humidity of about ______%

55%

Suction superheat at the evaporator outlet for a medium temp walk in cooler should be between

6-10

The design space temp range for comfort cooling is between ______ & _______

70 & 80

Design space temp conditions for comfort cooling is _________ with ________% RH

75, 55%

Suction superheat at the evaporator outlet for comfort cooling using a TXV should be between

8-12

Design entering water temperature for recirculating water cooled equipment is

85

Design entering air for condensers in Miami,FL is

95

What is an indication there may be wax at the valve seat

A sudden rise in suction pressure when the system shuts down

What are the indications of a TXV Valve seat leakage

After shutting system down a whistling or gurgling sound can be heard

A _________ is the quantity of heat required to raise the temps of 1 lb of water 1 degree C between 32-212

BTU

A ___________ evaporator is a heat exchanger hat uses enhanced flat plates that are brazed together to prevent leakage

Brazed plate evaporator

What is the first step in a systematic analysis of a TXV performance

Checking the systems superheat

On an externally adjusted TXV, turning the adjustment stem _______________, will increase the superheat setting

Clockwise

A ________________ is a type of geothermal ground loop system that draws ground water from a well directly into a building

Closed loop system

The types of ___________ systems include horizontal, vertical and surface water closed loop system

Closed loop systems

The term ____________ is used to describe the fact that most building zones in light commercial areas are not in the cooling mode at the same time

Diversity

Pressure drop due to the distributor ____________ reduce the capacity of the system

Does not

A ____________ evaporator is a heat exchanger in which refrigerant boils from a partial liquid/has mixture to 100% gas before the refrigerant leaves the evaporator

Dry-type evaporator

How can a suspicion of wax in a TXV be checked

Encase the valve in dry ice during disassembly . Check for wax at valve seat & pin

What type of TXV must be installed with a distributor of he centrifugal type, the venturi type, or the pressure drop type

Externally equalized TXV

Rapid cooling of the distributor by submerging in water after soldering the tubing is permissible

False

The best method for keeping the air in building spaces comfortable is to adjust the air circulation to maintain building temps

False

The major problem with dry-type evaporators is that liquid refrigerant may easily get into the compressor and cause severe damage

False

Thermostat cycling should always be used to reset heat pumps after an operational fault

False

Discomfort is the condition that occurs when a person cannot sense a difference between themselves and the surrounding air

False; they can sense the difference

A ____________ evaporator is a heat exchanger in which a float or other device ensures that the entire evaporator is full of liquid refrigerant

Flooded evaporator

What is the state of the refrigerant in the discharge line entering the condenser

High pressure, high temp, super heated vapor

A _____________ is a condition where the evaporator pressure, temperature and superheat values are higher than normal because of application conditions

Hot pull down

_________ is the amount of moisture, or water vapor in the air

Humidity

When multiple heat pumps are in heating mode, heat is extracted from the ____________

Hydronic loop

A _____________ control system is a grouping of electrical devices that control water temps and flow in a hydronic loop and geothermal loop

Hydronic loop control system

A decrease in the superheat setting of a cross-charged TXV will ___________ the MOP of the valve

Increase

When changing the superheat on an internally adjusted TXV, compressing the spring will ____________ the superheat

Increase

If too much refrigerant is fed to the evaporator he superheat will be ____________

Low

The _____________ side of a mechanical refrigeration system consists of an expansion device, evaporator, suction line and a number of accessories

Low pressure side

What is the state of the refrigerant in the suction line leaving the evaporator

Low pressure, low pressure, superheated vapor

__________ loop systems are most common in residential and light commercial applications

Open

A cooling tower can be of the __________ or _________ type

Open or closed loop

Soldering of the TXV to the distributor is to be done one the _____________ of the distributor

Outside

Name the three fundamental pressures that control the operation of the TXV

P1 - bulb pressure P2 - evaporator pressure P3 - spring pressure

Which type of distributor uses a nozzle to control the capacity of the distributor

Pressure drop type distributor

Why is pressure drop important to the operation of a gas-charged TXV

Provides a higher temperature at the diaphragm and prevents loss of control

____________________ is the amount of moisture in air compared to the amount of moisture the air would hold at the same temperature when air is saturated

Relative humidity

One part of the liquid line being colder than another indicates a _______________

Restriction

_____________ is sensible heat added to refrigerant after it has changed state from a liquid to a gas

Superheat

A __________ loop system is a type of geothermal loop system that circulates water through a loop heat exchanger in a lake or pond in order to exchange thermal energy

Surface water closed loop system

State the function of the TXV in the simplest of terms

To cause a drastic pressure drop across he valve & to supply the evaporator with enough refrigerant to satisfy all given load conditions

What is the purpose of a refrigerant distributor

To distribute a somewhat even amount of liquid refrigerant to each circuit. To increase refrigerant velocity through the evaporator causing a "scrubbing effect" returning oil to the compressor

Why should distributor tubes be of equal length

To ensure maximum distribution efficiency to each evaporator circuit

Evaporation is the process that occurs when a liquid changes to a vapor by absorbing heat

True

Heat sinks are needed for water source and geothermal heat pump systems

True

Humidity is always present in the air

True

Humidity level is controlled by humidifiers and dehumidifiers

True

Low temperature evaporators operate at a temperature below freezing

True

Make up air is air that is used to replace air that is discharged as exhaust

True

Most air conditioning systems use a centrifugal fan to circulate return room air across an evaporator

True

Pressure drop in the distributor does not reduce the capacity of the system

True

The external equalizer line must be installed beyond the point where f the greatest pressure drop

True

The major difference between water source and air source heat pumps is that water is used in the refrigerant heat exchangers of water source heat pumps

True

The short term effect of a loop performance is the change in ground temperature that occurs over many years

True

_____________ evaporators are used is water source heat pumps

Tube-in-tube

A ____________ evaporator is a type of water medium heat exchanger that consists of a small tube inside of a larger tube

Tube-in-tube evaporator

A __________ loop system is a type of geothermal ground loop system in which U—tube ground loops that circulate water inserted into holes drilled perpendicular to the surface

Vertical closed loop system

____________ evaporator is an evaporator that uses a pump to circulate water across its coil to give up heat to the refrigerant

Water medium evaporator

A ___________ control is a tstat that controls system fans, reversing valves and expansion device when the hydronic loop controls are activated

Water source heat pump

What should be done to see if the remote bulb of a gas charged TXV has lost control

Wrap the bulb with a tag saturated in warm water

A properly operating evaporator contains ______________ refrigerant

boiling saturated (80/20)


संबंधित स्टडी सेट्स

AP Art History Chapter 5: Ancient Greece

View Set

abeka 7th grade science section review 12.6

View Set

Chapter 1: The basics of Nutrition

View Set

Chapter 49: Nursing Care of the Child With an Alteration in Genetics

View Set

PHYSICAL SCIENCE - Chapter 3 Quiz

View Set