Developing Electrical Troubleshooting TPC
Thermal overload relays can generally be reset after cooling for about
1 minute
NEMA recommends seasoning linear lamps for _____ hr before dimming
12
When troubleshooting a starter, if line voltage is present, the problem is probably in the
? mechanical,hydraulic, or pneumatic
On an electrical diagram, a control relay is indicated by the designation
CR
Which of the following is not typically used to identify conductors in a motor-control circuit?
Colors
Which of the following provides both overload protection and short-circuit protection in one unit?
Combination motor starter
Most equipment manufacturers adhere to some kind of standard for electrical prints and symbols; the most widely used is the one proposed by
JIC
The color temperature of the light produced by a lamp is expressed in degrees
Kelvin
Which of the following are NOT typically connected to a control relay?
Motors
Which type of occupancy sensor detects the difference in heat emitted by humans in motion from that of the background space?
PIR sensor
Which of the following would show where the power-distribution system, ducts, and manholes are located for a manufacturing plant consisting of several buildings?
Plot plan
High temperature is an indication of a(n) __________ pole-phase group in a polyphase stator
Shorted
Which are most affected by overvoltage?
Slow-speed motors(not sure)
Which of the following is NOT a common cause of mechanical vibration?
Worn brushes
An open armature winding in a dc motor is indicated by
a decrease in speed
Deterioration in a selenium rectifier is indicated by
a gradual rise in the input current
If one phase of a three-phase, Y-connected winding is shorted, the ammeter will indicate
a higher current in the shorted phase
Operation of an air-piloted valve is initiated by
a surge of air
Cross-references to the different locations of limit switches in a diagram are provided by
arrows next to the symbol's line number
The ____________ contacts on a motor starter provide a parallel path for the current to the coil
auxiliary
A gaseous discharge lamp, such as a fluorescent or an HID, requires a(n) ____________, to provide proper starting voltage and regulate current.
ballast
One of the best ways to learn about new equipment is to begin troubleshooting
before installation
A latched electrical relay is an example of a
bistable
In a pneumatic circuit, leakage of air during the actuating part of the cycle
can usually be ignored
Dimming high-pressure sodium HID lamps can cause
color shift
The systematic testing of all controls in a building to ensure that they perform and interact properly is known as
commissioning
DC motors and generators have ____________, which cause special problems not normally found in ac machines.
commutators and brushes
On a building blueprint, a solid electrical line generally indicates a ____________ in the ceiling, while a dashed line indicates the same thing concealed in a concrete floor.
conduit
When you test a three-phase, delta-connected winding with a compass, the compass will indicate alternating north and south poles when the pole-phase groups are
connected properly
When preparing an elementary diagram, you should number all lines with __________ numbers
consecutive
If you close the contacts of a motor controller and measure a potential difference of zero between the motor terminals, the fault is probably in the
controller
If you find a defective relay coil, you should replace it. Test the new coil for proper ____________ with a ____________.
current clamp on ammeter
One added feature of newer motor starters is a single-phase sensor that detects
current unbalance
In a pneumatic circuit, a check valve allows flow in only one direction. In an electrical circuit, this function is performed by a(n)
diode
When troubleshooting combination starters, the number-one symptom of a problem is the operator saying, "The motor ____________."
does not run
In a shunt motor, the field windings are separately ____________ so they carry just a fraction of the load current compared to the full load current of the series motor's field windings.
excited
The following symbol represents an ____________ outlet in a ____________.
exit light; wall
On architectural working drawings, an electrician is concerned mainly with the electrical drawings superimposed on the
floor plan
The no-load current in a three-phase rectifier is typically 6 to 10% of the ____________ current, and usually includes the cooling fan motor.
full load
In autotransformer input circuits, each input line should be
fused
The three most common causes of electrical failure in three-phase motors are shorted, ____________, and burned out windings.
grounded
Planned lighting maintenance primarily consists of _____ to economize on labor, _____ to optimize light levels and space appearance, and _____ to correct abnormalities in operation
group relamping; fixture cleaning; troubleshooting
Each motor in the plant should bear a metal tag with the __________ stamped on it
inventory number
A sequence of operation
is used with an elementary diagram
A helpful piece of information to have when revising a control circuit is the ____________ wire or relay number. This information keeps you from having to hunt through the whole schematic for it.
last
A relay that has "dogs" located directly above the operating bar is called a ____________ relay
latching
A detailed step-by-step description of all input commands, logic responses, outputs and machine motions is provided on the
log
A good diode has a resistance that is
low in one direction, high in the other
Overvoltage, excessive current and too-frequent operation are possible causes of
magnetic coil is burned or short circuited
On a rewound three-phase motor, occasionally an entire pole-phase group may be accidentally reversed. This results in overheating and an increase in the ____________ of the machine
magnetic hum
On a rewound three-phase motor, occasionally an entire pole-phase group may be accidentally reversed. This results in overheating and an increase in the ____________ of the machine.
magnetic hum
The first step in troubleshooting a fluorescent lighting system is to
make sure the lamp is seated properly and contact is good
The kind of lubrication that should be used in a bearing is determined by the bearing's
maximum operating temperature
Most reversing starters with low-voltage remote pushbuttons are all of the following EXCEPT
mechanically interconnected
Mechanical linkages of motor contacts, relays, and solenoids on new equipment should
move freely
Commutator overheating is sometimes caused by the direction of rotation of the motor being changed without changing the position of the brushes to the new ____________ plane.
neutral
In the identification 8TR15XTO, the X indicates
normally closed
You can measure the current in the leads of a three-phase motor with a clamp-on ammeter; the continuity of the motor is tested with a(n)
ohmmeter
On a reversing starter, mechanical interlocks are used to prevent both sets of three-phase contacts from being operated at the same time. The closing of ____________ operates a mechanism that prevents the closing of the opposite contactor.
one contactor
A power-installation drawing shows
only power outlets
Maintained start-stop devices provide
only undervoltage release
Adding limit switches to the control circuit of a reversing motor provides
overtravel protection
The ____________ circuit of an electrical schematic is the simplest part of the diagram and the easiest to follow.
power
A riser diagram shows the
power distribution wiring from input through output
If you suspect that a ground fault is the cause of a machine's electrical problem, make careful checks with the
power off
When you arrive to troubleshoot a defective machine, the next thing to do after talking to the machine operator is to
press the START button
Most methods of reducing motor speed when using multispeed controllers involve the operator
pressing the STOP button
A film of oil on the commutator does all of the following EXCEPT
prolong brush life
Operating a heavily loaded motor at __________ can cause a high slip
reduced voltage
When checking faults in a single-phase, split-phase motor, test both the ____________ windings for grounds, opens, and shorts.
run and start
Rapid-start fluorescent systems are ____________ circuit systems
series
In the electronic timing relay, the time-delay assembly is connected in
series with the relay coil
On a blueprint, wall outlets are indicated by a circle with a
short line drawn to it
A one-line diagram shows paths of energy transfer rather than individual current paths. For example, to show a three-phase, four-wire circuit, it would use a ____________ line ____________.
single; for all the wires
Most control cycle faults are remedied by locating and correcting ____________ errors, which can be very difficult to diagnose.
switching
In addition to the locations of lighting and lighting panels, lighting diagrams show the locations of
telephone outlets
All of the following are common reasons why a split-phase motor makes a noticeable noise when operating, EXCEPT
too little end play
If a motor stops for no apparent reason and you are called to inspect the motor starter, the first thing you should check is the
trip levers on the thermal overload relays
Changing the number of magnetic poles in the stator of a squirrel-cage motor permits the motor to run
two or more fixed speeds
A circuit that provides undervoltage release and has two wires connected to the pilot device that energizes the magnetic control circuit is said to have
two-wire control
Mixing brush grades in a dc motor causes
unequal load distribution among brushes
The NEC requires a fuse to be installed in all __________ conductors
ungrounded
Worn or damaged ball and roller bearings are easily detected by the ____________ they produce.
unusual noise
A pneumatic shuttle valve is used for operating a conventional pneumatic ____________ or electrical relay from either of two control sources.
valve
The actual location and routing of circuits is shown on a
wiring diagram
Open circuits in split-phase motors are most often caused by loose or dirty connections of the centrifugal switch. Sometimes noisy operation of the motor is caused by a(n) ____________ centrifugal switch.
worn