The International Residential Code specifies a minimum stair tread depth of _____
10 inches
The maximum rise for a set of stairs without a landing is typically ___
12 feet
When building a stair with a total rise of 7'-7", the number of risers required and their unit rise is ___
13 risers, each 7" high
For user safety, the IRC specifies that the greatest riser height should not except the smallest riser by more than____
3/8 inch
The minimum and maximum tread depths of a stairway should not differ by more than___
3/8"
Diagram D shows ____ stairway
Narrow-U
Diagram B shows ___ stairway
Wide-L
Diagram C shows _____ stairway
Wide-U
The basic parts of a stairway are risers, treads, and ___
center-cut-stringers
Which type of stringer is typically used for stairways with open riser designs?
dadoed
Tread width (uni run) is measured from the ___
face of one riser to the face of the next riser
When a ledger is installed to strengthen a stair assembly, treated lumber must be used if the ledger is ____
fastened to a concrete floor
To add strength to the stair assembly, a pressure-treated 2 X 4 may be fastened to the floor to serve as a ___
ledger
All of the following are parts of a balustrade except ____
nosing
If stairway drawings are incomplete or in conflict with the building code, the carpenter should ___
notify a supervisor
Diagram A shows ____ stairway
open stairway
The most important concern in the design of any stairway is ___
safety
For more efficient stair layout, the rise and run measurements on a framing square can be marked by using ___
stair guages
What component is secured to one side of the stringer below the cut notches to add strength and rigidity?
strongback
On a 36" wide wood stairway, a center cutout stringer is required if ___
the tread material is thinner than 1 1/2"
Rule 2 for calculating rise-to-run ratio is stated as ____
tread width + (2 X riser height) = 24" to 25"
The horizontal distance from the face of one riser to the face of the next riser is the ___
unit run
When laying out a stringer using a framing square, the blade of the framing square represents the ___
unit run