NEC 200 & 210
At the time of installation, grounded conductors _____ AWG or larger can be identified by distinctive white or gray markings at their terminations.
4
At least one receptacle outlet not more than _____ ft above a balcony, deck, or porch shall be installed at each balcony, deck, or porch that is attached to and accessible from a dwelling unit.
6 1/2
In a dwelling unit, illumination for outdoor entrances that have grade-level access can be controlled by _____ control.
Any of these: remote/ central/ automatic
Article 210 provides the general requirements for _____.
Branch Circuits
In a dwelling unit, at least one lighting outlet _____ shall be located at the point of entry to the attic, underfloor space, utility room, or basement where these spaces are used for storage or contain equipment requiring servicing.
Containing or controlled by a switch
GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in _____.
Crawl spaces
The identification of terminals to which a neutral conductor is to be connected shall be substantially white or _____ in color.
Silver
The number of receptacle outlets for guest rooms in hotels and motels shall not be less than that required for a dwelling unit. These receptacles can be located to be convenient for permanent furniture layout, but at least _____ receptacle outlet(s) shall be readily accessible.
Two
Two or more _____ small-appliance branch circuits shall be provided to supply power for receptacle outlets in the dwelling unit kitchen, dining room, breakfast room, pantry, or similar dining areas.
20A
Receptacles installed in bathrooms within six feet of the outside edge of a _____ shall have GFCI protection.
Bathtub or shower stall
All 125V through 250V receptacles supplied by single-phase branch circuits rated 150V or less to ground installed in dwelling unit boathouses shall have _____ protection for personnel.
GFCI
__________ conductors shall not be used for more than one branch circuit, one multiwire branch circuit, or more than one set of ungrounded feeder conductors except as allowed elsewhere in the Code.
Neutral
The insulated grounded conductor(s) in a multiconductor cable _____ AWG or larger, shall be permitted to be re-identified at the time of installation at its terminations.
4
In dwelling units, GFCI protection shall be provided for all 125V through 250V receptacles supplied by single-phase branch circuits rated 150V or less to ground where receptacles are installed within _____ ft from the top inside edge of the bowl of a sink.
6ft
In other than dwelling locations, GFCI protection is required for all single-phase receptacles rated 150V to ground or less, 50A or less and three-phase receptacles rated 150V to ground or less, 100A or less in unfinished portions or areas of the basement.
True
Receptacles installed for countertop and similar work surfaces as specified in 210.52(C) shall not be considered as the receptacle outlets required by 210.52(A).
True
In devices or utilization equipment with polarized connections, identification of terminals to which a neutral conductor is to be connected shall be substantially _____ or silver in color.
White
The continuity of a grounded conductor shall not depend on a connection to _____.
a metallic enclosure, a raceway, cable armor
The screw shell of a luminaire or lampholder shall be connected to the _____.
grounded conductor
For attics and underfloor spaces, utility rooms, and basements in all occupancies, at least _____ lighting outlet(s) containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment requiring servicing.
one