NEC 200 & 210

Pataasin ang iyong marka sa homework at exams ngayon gamit ang Quizwiz!

At the time of installation, grounded conductors _____ AWG or larger can be identified by distinctive white or gray markings at their terminations.

4

At least one receptacle outlet not more than _____ ft above a balcony, deck, or porch shall be installed at each balcony, deck, or porch that is attached to and accessible from a dwelling unit.

6 1/2

In a dwelling unit, illumination for outdoor entrances that have grade-level access can be controlled by _____ control.

Any of these: remote/ central/ automatic

Article 210 provides the general requirements for _____.

Branch Circuits

In a dwelling unit, at least one lighting outlet _____ shall be located at the point of entry to the attic, underfloor space, utility room, or basement where these spaces are used for storage or contain equipment requiring servicing.

Containing or controlled by a switch

GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in _____.

Crawl spaces

The identification of terminals to which a neutral conductor is to be connected shall be substantially white or _____ in color.

Silver

The number of receptacle outlets for guest rooms in hotels and motels shall not be less than that required for a dwelling unit. These receptacles can be located to be convenient for permanent furniture layout, but at least _____ receptacle outlet(s) shall be readily accessible.

Two

Two or more _____ small-appliance branch circuits shall be provided to supply power for receptacle outlets in the dwelling unit kitchen, dining room, breakfast room, pantry, or similar dining areas.

20A

Receptacles installed in bathrooms within six feet of the outside edge of a _____ shall have GFCI protection.

Bathtub or shower stall

All 125V through 250V receptacles supplied by single-phase branch circuits rated 150V or less to ground installed in dwelling unit boathouses shall have _____ protection for personnel.

GFCI

__________ conductors shall not be used for more than one branch circuit, one multiwire branch circuit, or more than one set of ungrounded feeder conductors except as allowed elsewhere in the Code.

Neutral

The insulated grounded conductor(s) in a multiconductor cable _____ AWG or larger, shall be permitted to be re-identified at the time of installation at its terminations.

4

In dwelling units, GFCI protection shall be provided for all 125V through 250V receptacles supplied by single-phase branch circuits rated 150V or less to ground where receptacles are installed within _____ ft from the top inside edge of the bowl of a sink.

6ft

In other than dwelling locations, GFCI protection is required for all single-phase receptacles rated 150V to ground or less, 50A or less and three-phase receptacles rated 150V to ground or less, 100A or less in unfinished portions or areas of the basement.

True

Receptacles installed for countertop and similar work surfaces as specified in 210.52(C) shall not be considered as the receptacle outlets required by 210.52(A).

True

In devices or utilization equipment with polarized connections, identification of terminals to which a neutral conductor is to be connected shall be substantially _____ or silver in color.

White

The continuity of a grounded conductor shall not depend on a connection to _____.

a metallic enclosure, a raceway, cable armor

The screw shell of a luminaire or lampholder shall be connected to the _____.

grounded conductor

For attics and underfloor spaces, utility rooms, and basements in all occupancies, at least _____ lighting outlet(s) containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment requiring servicing.

one


Kaugnay na mga set ng pag-aaral

CH 14- Small Business Finance: Using Equity, Debt, and Gifts

View Set

Patho Chapter 33: Diabetes mellitus & metabolic syndrome

View Set

Fundamentals of Nursing CH 21, 22, 27, 29, 40, 41, 42

View Set

Bio-Chapter 19- Taxonomy, Systematics, and Phylogeny

View Set

Insurance Regulation - Chapter 7

View Set

Ego Defense Mechanisms (GNP II-Psych Exam 1)

View Set

Ch. 8 End of Ch. Questions Exam 2

View Set