SWLCAT 1-1 cont
False
An improperly sharpened gaff is safer than a gaff that has not been sharpened at all
True
To help prevent climber cut outs, gaffs must be sharp, properly sized, and properly shaped
Attach snap hook to an appropriate anchor point
What is the first and most critical step when performing a self rescue
310lbs
Bucket truck rescue systems are designed for a single person load up to (blank)
False
Shoulder d rings can be used for fall arrest
False
There are 4 basic steps in a pole top rescue
440lbs
Bucket truck rescue systems are designed for an exceptional two man descent up to (blank)
False
If a harness shows signs of minimal fraying, it should be discarded
Replaceable
Climbing gaffs are available in two types, solid and (blank)
True
Side d rings are not intended for fall arrest
False
The OSHA fall protection standard does not contain training requirements
True
The cleat must be present in the WPFR device to work properly
1"
The gaff is properly shaped and sharpened when it begins holding a distance of (blank)
True
The keeper/gate of snap hook should be positioned so that it is never load bearing
Person using climbing equipment
The one with the responsibility for inspecting, maintaining, and rejecting climbing equipment is the (blank)
6'
Warning lines, used in warning line systems, shall be erected at least (blank) from the roof edge when no mechanical equipment is being used
1
When using the ox block for rescue, a minimum of (blank) wraps must be used
Hitch/carabiner
A fall arrest attachment with a web loop must be attached to a harness with a (blank) or a (blank)
20 years
A pole that is over (blank) old should be supported with a line truck boom or other device in case it is unstable
3:00 and 9:00
If pole was a clock, where should the hardware of the WPFR device be placed
Take strap out of service
If red warning core of WFPR straps is showing, then what should be done
False
The person responsible for sharpening and properly shaping the climbing gaffs is the manufacturer
5,000lbs
Fall arrest anchor points must support a minimum of (blank) per attached worker and be independent of worker support
Above
For fall arrest, anchor point should always be kept (blank) the rear fall arrest attachment
High
When a pole is raked, it should be climbed on the (blank) side
True
When descending a pole, longer steps are better than shorter steps
Evaluating the situation
Deciding if rubber gloves are needed for a pole top rescue is part of (blank)
Place the climber on the leg, hold sleeve with hand before lightly jabbing
During a pole cut out test, the proper procedure is to (blank)
8" to 10"
Effective stroke distance when climbing up a pole is (blank)
True
Hitchhiking method should be used to climb with a WPFR device
Proximity to pole
Inner strap accommodates for (blank)
False
It is proper procedure to use a training unit on a job
False
Knots and knotholes are not hazards that contribute to cut out accidents because the gaffs are shaped to deal with them
True
The point of the gaff should cut the pole surface at a maximum of 2 inches
2'
The stern also d ring is for fall attachment when likely fall distance is not greater than (blank)
Work positioning
The suspension bride is only used for (blank)
False
The tip of the gaff should have a spike point
4
There are (blank) acceptable methods of bucket rescue
Visually inspect it
To ensure that a snap hook is fully engaged, a worker should (blank)
A rescue trainer
To practice a pole top rescue, (blank) should be used
True
When climbing a pole, carrying the hand line on a breakaway hook will help eliminate the hazard of being pulled off the pole by something snagging the hand line
Directly across from the anchor point
Where should a worker exit the bucket once the rescue system has been attached
Middle back near shoulder blades
Where should lanyards be attached on harnesses
8"
While climbing and working on a pole, it is important to keep knees about (blank) away from the pole
Cover or shield the hazard
If a hazard cannot be removed from a pole that is about to be climbed, one should (blank)
1/2"
If a special rescue rope is used, it will usually be made of (blank) nylon
True
If accidents are to be reduced on the job, the climber must develop a safety conscious attitude
Discard the harness
If hardware is bent on a harness, then the qualified electrical worker should (blank)
True
Once a pole top rescue victim is secured, the victims safety strap is cut on the opposite side of desired swing
Cracks, cuts, and or marks
Climber shank and sleeves should be inspected for (blank)
14" to 20"
Climbers are adjustable in lengths from (blank)
True
If the gaff slides along the wood without digging, then the gaff is either improperly sharpened or the gaff angle is too small
8.5'
In the rescue block method of bucket rescue, the anchor point should be located (blank) from the lip of the bucket
True
Of victim of pole top accident is no longer in contact with energized conductors, the rescuer should proceed with the rescue
Primary/fall arrest
The dorsal d ring, pigtail d ring, or web loop are the (blank) for (blank) attachment
True
To comply with OSHAs requirement that impact force of a fall shall not exceed 1,800 lbs of force, a harness should be used with a deceleration unit
Inner
When performing a rescue, the (blank) strap of wood pole fall restriction device should be cut
1/4"
When performing the cut out test, at what distance should the gaff be pushed into the pole
Call for help
When there is an injured worker on a pole, the first thing that should be done is (blank)
Communicate orally with workers
When using safety monitor program, a competent person has to be close enough to the workers that they can (blank)
As needed
Once a pole top victim is lowered to ground, first aid and or CPR should be administered (blank)
False
One good climbing practice that will help avoid accidents is to practice taking extra large steps when ascending, climbing, or descending
Before climbing to the rescue position
Planning a pole top rescue should be done (blank)
Connecting device only
Positioning side d rings are intended for attachment of (blank)
Free fall is limited to 2'
Qualified electrical workers are permitted to work out of the secondary lanyard if the (blank)