in spectrophotometry, different molecules absorb light at different ______

wavelengths

which is the hottest region of the plasma torch in ICP

2 plasma region

which of the following is not one of the detectors used in a spectrophotomete? infra-red detector electron capture detector photomultiplier detector photodiode array

electron capture detector

in an ___, the dependent variable is the intensity of emission and the independent variable is the wavelength

emission spectrum

which of the following statement(s) about the fluorescense and fluorometer is (are) TRUE?

fluoresecne is an example of luminescence, fluorescence is more sensitive than absorbance spectrophotometry, the two monochromators are placed 90 from one another in a flourometer instrument.

. Two monochromators positioned at right angles is a characteristic of which instrument?

fluormeter

spectrophotometers use a monochromator containing a _____ to select the ____ assigned for measuring the absorbance of an analyte.

grating, wavelength respectively

which of the following statements is correct

X-ray radiation has a shorter wavelength than visible light

in an emission spectrum the ___ is constant and the ___ is the variable

^ex, ^em respectively

what is a chromophore

a group of atoms in a compound responsible for the absorption of electromagnetic radiation

Which of the following is proportional to concentration

absorbance

a solution has an absorbance of .62 at 595 nm. As you make the solution more and more dilute, what happens to its absorbance at 595 nm

absorbance will decrease

the general types of atoic spectroscopy are :

absorption, fluorescenece and emission

In a scanning absorption spectrum, the dependent variable is .......... and the independent variable is .............

absorption, wavelength

in a scanning absorption spectrum, the dependent variable is ______and the independent variable is _____

absorption, wavelength

the fuel gas used in flame atomic-absorption spectroscopy is ___ and the oxidant is ___

acetylene, air respectively

in strong acids, the measured pH is higher than the actual pH because the glass is saturated with H+ and cant be further protonated. This error in pH measurements is known as

acid error

the gas used in Inductively coupled plasma is ___

argon

the purpose of a blank is to

cancel and subtract readings due to the absorbance of the reagents added to the analyte

When analyzing an analyte using atomic absorption spectroscopy the releasing agent is added to minimize the ________ interference

chemical

Atomic emission originates from excited energy levels. Atoms in inductively-coupled plasma are promoted to these higher levels by:

collisions with other atoms and ions in the plasma

at low concentrations the fluorescence intensity will generally be proportional to the ___ of the analyte

concentration

A ____ lamp is used as a source of light in uv-spectropohotmer, whereas a ____ lamp is used in case of atomic absorption spectroscopy.

deuterium arc, hollow cathode respectively

monochromatic light is defined as

electromagnetic radiation of one wavelength

one of the main advantages of a furance atomic absorption is that:

it requires only a very small quantity of a sample

what does the term monochromator mean

light of only one wavelength

When the H+ is very low and NA+ is high the electrode starts to respond to Na+ gving a pH ____ than the true pH. This is known as _____

lower, sodium error

for which of the following types of electromagnetic radiation would the photon have the lowest energy

microwave

the intensity of the transmitted light is detected with a ____which is one of the light detectors

photodiode

the most common spectrophotometers are used in the ___ and ____ regions of the spectrum, and some of these instruments also operate into the near-infrared region as well.

ultraviolet, visible respectively

For a given element, the atomization method that can detect the lowest concentration is

plasma

When analyzing an analyte using atomic absorption spectroscopy the ________ is added to minimize the chemical interference

releasing agent

spectrophotometric analysis based on Beer's Law

requires the use of monochromatic light

compared to atomic-absorption (AAS) spectroscopy, inductively coupled plasma (ICP) has the advantage of providing:

simultaneous multi-element analysis

Interference resulting when two or more elements have emission spectra in overlapping wavelengths is referred to as:

spectal interference

the basis of the technique of chromatograpghy for seperating components of a mixture is

the interaction of the components with both stationary and mobile phases

which of the following is not one of the detectors used in a spectrophotometer?infrared detector, photomultiplier detector, thermal conductivity detector, photoiode array

thermal conducivity detector

____ is the lamp used in visible spectrophotometry

tungsten

which of the following statements about fluormetry are true

two monochromators are use in a fluormeter instrument