NEC Article _____ addresses air-conditioning and refrigeration equipment that incorporates hermetic refrigeration motor-compression

440

The allowable ampacity of a 4 AWG THHN conductors is 95 amperes. if we have four 4 AWG THHN conductors, what is the adjusted ampacity

76

What is the metric designator for a raceway of trade size 3

78

___ is a thin wall metal raceway that is not permitted to be threaded

Eletricial metallic tubing (EMT)

Which item in the general clauses and conditions is of value to the contractor and his estimator only

Notice to bidders

if more than one symbol is located immediately adjacent to another its usually means that a multi-gang box for multiple wiring devices and ____ are to be installed

a single cover

Proof of the flux cancellation principle can demonstrated using a clamp-on _____

ammeter

The difference in plugs and receptacles are based on the ____ and voltage rating of the device

ampacity

According to NEC table 220.12, armories and auditoriums should have a calculated unit load of at least____ volt-amperes per square meter

11

A sign outlet is assigned a minimum allowance of ____ volt amperes for each branch circuit required

1200

When sizing conductors and overcurrent protection, you must take 100 percent of the noncontinuous loads plus ____ percent of the continuous loads

125

For show window lighting, allow _____ volt-amperes per linear foot (660 volt-amperes per linear meter), or use the connected load if that value is higher

200

The two most popular types of PVC are Schedule 40 and Schedule__

80

If the ambient temperature anywhere along the length of a raceway is less than 78 degrees F or higher than ___ degrees F, the ampacity of the conductors in the raceway, or cable must be modified by a correction factor

86

In commercial buildings, ____ protection is required for all 125-volt, single-phase,15- and 20- ampere receptacles installed in bathrooms, in kitchen, on rooftops, outdoors, within 6ft from the outside edge of any sink, in indoor wet locations, in locker rooms with adjacent shower facilities, and in garages, bay, and similar areas

GFCI

Liquid-tight flexible nonmetallic conduits marked as ____ has a smooth seamless inner core and cover bonded together and one or more reinforcement layers between the core and covers for layered conduit.

LFNC-A

The wording on a counterfeit UL logo might say "approved" instead of"____"

LISTED

The term ____ is defined by the NEC as a channel that is designed and used expressly for the purpose of holding wires,cables, or busbar

Raceway

An exception to the ____ rule where two different temperatures are encountered for the same conductors permits the application of the higher ampacity(lower temperature) if the length of the conductors that enter a higher temperature is not more than 10 ft or not more than 10% of the total circuit length

ampacity derating

Who may submit a proposal to change the NEC using the proposal form found in the back of the NEC

anyone

Allowing metal shaving from a drilling operation to fall onto live parts of electrical equipment generally results in a ____,which can cause a deadly burn

arc blast

the construction plans for a building are often called ____

blueprints

Where PVC conduit is connected to box or enclosure, a ___ is recommended

box adapter

The phrase"____load" is used to designate when the value is in compliance with the requirements of NEC Article 220

calculated

When all conductors of the same alternating- current circuit are in the same raceway, the magnetic flux around each conductor ____ the magnetic flux of the other circuit conductors

cancels out

When raceways are installed vertically in the building, from one floor to another, the vertical direction may be represented by the arrow symbol inside a(n)

circle

Compression fittings for EMT are classified as rain-tight and ____-tight types

concrete

The phrase "____load" is used to designate the value of the value of the load as it actually exist

connected

When concealed raceways are drawn on plans, they usually are shown as____

curved .lines

A rectangle with parallel diagonal linies as the fill pattern represents a ____

distribution panel

when turning a standard disconnect switch on,___ of the switch

do not stand on the left

The symbol for ____ consists of two parallel lines inside, and sometimes extenfing out of a circle

duplex convenience receptacles

When a box contains fittings such as luminaire studs, clamps, or hickeys, the number of conductors permitted in the box is one less for ____ device

each type of

The cover that is placed on a recessed box containing a receptacle or a switch is called a ___

faceplate

When pulling three conductors or cables into a raceway, if the ratio of the raceway diameter to the conductor diameter is between 2.8 and 3.2, jamming can occur. With ____ or more conductors or cables, jamming is highly unlikely

four

When using cables for the wiring of 3-way switches, NEC 200.7(C)(1) permits the use of a conductor with insulation that is white or __ or has 3 continuous white stripes(not too common) as a switch supply only if the conductor is permanently reidentified by painting or other effective means

grey

the typical outlet notation "H" designates a ____ outlet

horizontally mounted

An ungrounded conductor is also known as a _____ conductor

hot

Voltage drop in a circuit is calculated by multiplying the current flow times the _____

impedance

Type MC cable is a factory assembled of one or more insulated circuit conductors with or without optical fibers members enclosed in an armor of ____ metal tape, or a smooth or corrugated metallic sheath

interlocking

To reduce "electrical noise"(electromagnetic interference), circuits with receptacle outlets that serve loads such as cash registers, computers, or other sensitive electronic equipment are often supplied by ____ receptacles

isolated ground

In the metric system, what is the prefix for 1000

kilo

To plan any electrical wiring project, the first steps is to determine the ____ that the electrical system is to serve

load

Flexible metal and nonmetallic conduit are commonly used to connect recessed or lay-in____. when used in this manner, electricians refer to it as a "fixture whip"

luminaires

_____ boxes are used primarily to install ceiling outlets

octagonal

Isolated ground receptacles are required by NEC 406.2(D) to have a(n) ____ triangle on their face

orange

_____ schedules are typically provided to detail the circiuits and overcurrent protection required for distribution equipment

panelboard

The purpose of the national electrical code is the practical safeguarding of ____ from hazards arising from the use of eletricity

persons and property

The NEC defines a(n)____ as one who has skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training to recognize and avoid the hazards involved

qualified person

At least one____ is required to be installed above each linear 12 ft (3.7 m) section of show window

receptacle outlet

In general, the letter-type designation it formerly referred to a _____-based covering and now indicates thermoset insulation

rubber

A ___ switch is used where it is desired to control a light or group of lights, or other load, from one switching point

single pole

A switch symbol without a number beneath the horizontal line means that a ____ switch should be installed

single pole

if the raceway is for use of the _____ system, the line will be broken and a uppercase T will be inserted

telephone

According to the supplementary general conditions,who is responsible for any utilities that are damaged

the contractor

Count the neutral conductor of a 4-wire,3-phase,wye connected circuit when the major portion of the load is electric discharge lighting (fluorescent, mercury vapor, high- pressure sodium,etc) data processing, and other loads where the neutral conductor carries____ current

third harmonic

Whenever a grouping of more then ____ current carrying conductors exists, an adjustment factor from NEC table 310.15(B)(3)(a) must be applied

three

a(n) _____ box is used for surfaces or concealed installations

trade size 4x4 square

The term____ means not connnected to ground or a conductive body that extends the ground connection

ungrounded

Conduit bodies are often referred to in the trade as "condulets" and "_____"

unilets


Set pelajaran terkait

Unit 11: Dynamic Assessment (Diag)

View Set

Chapter 6: Designing a Motivating Work Environment

View Set

Entrepreneurship Test Chapters 3 and 4

View Set

Behavioral Sciences MCAT- Chapter 9: Social Interaction

View Set

THEO 104- Quiz: Introduction to the Study of Jesus

View Set

Psychology of Advertising Exam #3

View Set