Heat Pumps

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

On the ground

A Packaged heat pump installed in a manufactured home is likely to be located

True

A ductless split-system heat pump is ideal for heating and cooling in a single area (T/F)

The earth

A geothermal heat pump extracts heat from

In the liquid line

A heat pump by-flow filter dryer is installed

Electric heat

A heat pumps COP is a ratio that compares its efficiency at producing heat to the heat produce by

Ensures a complete defrost

A wind baffle is used to

35 deg

Above what temperature is typically more economical to heat with a compression heat than a gas or oil furnace

Auxiliary heat

Air to air heat pumps are usually equipped with some form of

False

An electric force-air heating units used a sealed heat exchanger (T/F)

8 to 1

Compression ratios in a heat pump compressor can reach as high as

SEER

Dividing a units cooling output in Btus during its normal annual usage period by the total energy consumed during the same time determines

Temper the indoor air

During defrost, supplemental heaters supply

False

Frost cannot form on the outdoor coil of an operating heat pump unless the temperature is below 32 deg or less (T/F)

Limit switch

Fusible links in an electric heater are design to act as a back-up for the

kW input x 3413

Heating COP is calculated by deviding Btuh output by

At or near 100% or the buildings full heat load

How are auxiliary electric heaters typically sized for a heat pump system

Multiply each kW by 3413

How are kilowatts converted to Btus

It reverses the refrigerant flow through the indoor and outdoor coils

How does the reversing valve switch a heat pump between the heating and cooling modes

100 psi

How much pressure difference is needed to move the piston inside a reversing valve

Compressor operation for heating is locked out

In a hybrid heat pump, when the outdoor temperature drops the balance point

Outdoor coil

In a split-system air-to-air heat pump, the coil that absorbs heat in the heating mode is referred to as

The roof

In southwestern United States, package heat pumps are often installed on

Vapor line

In the heating mode, refrigerant leave the compressor and enters the indoor coil through the

The condenser

In the heating mode, the indoor coil is

5kW

In what increments are electric resistive heaters package usually sized

The evaporator

On the heating mode, the outdoor coil is

Wireless remote

Room temperature control using a ductless split-system is often done with a

1

The COP of an electric resistance heater can never be higher than

Season

The Preference Factor provides the ratio of the total heating or cooling energy delivered to the energy consumed during a

The Air Conditioning and Refrigeration institute (ARI)

The SEER standard was develop by

Number of resistance heaters used

The heat output of an electric force-air heating system is determined by the

Spiraled wire

The heating elements in a electric force-air heating systems are made of

Prevent overheating

The pospuse or a limit switch in an electric heat fan coil is to

False

There is still heat available that a heat pump can extract, even if the air temperature drops to 0 deg K (T/F)

14

To achieve an ENERGY STAR rating, a package heat pump must have minimum SEER of

Compression heat is locked out

What happens in a electric heat pump heating system when emergency heat is selected

Protect agains the lost of charge

What is the primary purpose of a low-pressure control on a heat pump

A wind baffle

What might be required when installing a split system heat out door unit on a exposed roof top

False

When a particular heat pump is referred to as a water-source unit, it is generally accepted that it is circulating water thought the building to provide heat (T/F)

Heater is cold

When calculating the kW output of a resistive heating element, a correction factor is apply when

On the indoor and out door coils

Where do you install a fix-orifice metering device on a air-to-air split-system heat pump

Outdoor unit

Where is the reversing valve typically located in a split-system air-to-air heat pump

The indoor fan runs

Which condition occurs during the defrost cycle of a single stage air-to-air heat pump

Air-to-water

Which heat pump type is commonly used to supply domestic hot water

Plastic tubing

Which material is used in the buried ground loop of a geothermal heat pump

Proper water drainage

Which of the following is the most important reason to level the outdoor section of an air Sourse heat pump

Electronic defrost control uses logic to determine the need for a defrost cycle

Which of the following statements are correct

It is warmer in Florida

Why is the actual HSPF of a heat pump installed in Florida higher than the same unit installed in Vermont