PD 1096 (PROFESSIONAL PRACTICE QUIZ)
1977
When was the Presidential Decree No. 1096 signed into law?
IMPERVIOUS SURFACE AREA
ISA
BUILDING BULK
A volume quantity
ALLOWABLE MAXIMUM BUILDING FOOTPRINT
AMBF
Article 1723
Article___________ of the Civil Code that states the liability of an Engineer and Architect who dew up the plans and specifications.
Warehouse
Below are under General Institution, except 1 Education Medical Medical Warehouse
PERCENTAGE OF SITE OCCUPANCY
PSO
3.00m
R-3 Occupancy what is the basic setback frontage requirement?
TGFA
Refers to the total floor space inside the building.
REPAIR
Remedial work done on any damaged or deteriorated portion/s of a building/structure to restore its original condition
3.6mW x 18.00mL
Standard Parking Slot size for Articulated Truck parking
2.15mW x 6:00mL
Standard Parking Slot size for a Car in parallel parking
TOTAL GROSS FLOOR AREA
TGFA
TOTAL LOT AREA
TLA
TOTAL OPEN SPACE WITHIN LOT
TOSL
National Building Code of the Philippines
The Presidential Decree No. 1096 shall be known as?
3.0 storeys or 9.0m
The RROW width also dictates the BHL6-7m RROW: for 6-7m RROW, the allowable BHL is?
Building Officials
The ________ shall be responsible for carrying out the provisions of this Code in the field as well as the enforcement of orders and decisions made pursuant thereto.
FIRE RESISTIVE RATING
The degree to which a material can withstand fire
DEMOLITION
The systematic dismantling or destruction of a building/ structure, in whole or in part
Type III
These buildings shall be of Masonry and wood construction with One hour fire resistive throughout and Incombustible exterior walls.
Type IV
These buildings shall be of Steel, iron, concrete, or masonry construction with Incombustible interiors (ceilings, walls)
Type I
These buildings shall be of wood construction.
300mm thk , with 1000mm below the surface of the ground
What is standard foundation provision for a GROUP A Dwelling?
Minimum width: 750mm
What is the Minimum width for a stairs?
Provides a framework of minimum standards Guide for requirements for all buildings to regulate their location, design, quality of materials, construction, and use
What is the Purpose of the Code?
2.5 storeys or 7.5m
What is the allowable BHL for a RROW of 4- 5m?
150kg/sqm
What is the allowable Second floor Structural live Load for a Group A dwellings
5 sets of plans and specs, signed and sealed by various professionals
What is the number of set of plans and specs required for Permit requirements?
Before constructing, altering, repairing,converting, moving, adding to,demolishing a building.
When is a building permit required?
Construction does not commence within 1 year from date of issuance. Construction does not resume 125 days after suspension of abandonment of work.
When is the building permit expires? under what scenarios.
Building Official
Who undertakes inspection of buildings?
Land
Zones are assigned to______________.
1.50m
minimum dimension in cluster living units with adjacent courts
EASEMENT
situated outside of private property limits
CONVERSION
A change in the use or occupancy of a building/ structure or any portion/s thereof which has different requirements
BUILDING PERMIT
A written authorization granted by the Building Official to an applicant allowing him to proceed with construction after plans, specifications and other pertinent documents have been found to be in conformity with the Code
ALLOWABLE MAXIMUM VOLUME OF BUILDING
AMVB
CONSTRUCTION
All on-site work done from site preparation, excavation, foundation, assembly of all the components and installation of utilities and equipment of buildings/structure
Construction
All on-site work done from site preparation, excavation, foundation, assembly of all the components and installation of utilities and equipment of building is called?
ADDITION
Any new construction which increases the height or area of an existing building/structure
RENOVATION
Any physical change made on a building/ structure to increase its value, utility and/or to improve its aesthetic quality
FIRE ZONE
Areas within which only certain types of construction are allowed, based on their occupancy, type of construction, and resistance to fire
Group I
Assembly with 1000 or more occupant loads are classified under___________.
BUILDING HEIGHT LIMIT
BHL
Group E
Business and Mercantile are identified and classified as _______.
CERTIFIED FLOOR AREA
CFA
ALTERATION
Construction in a building/ structure involving changes in the materials used, partitioning, location/ size of openings, structural parts, existing utilities and equipment but does not increase the overall area thereof.
18
For public universities , what is the parking slot provision for a school bus considering the school has 3,500 students.
GROSS FLOOR AREA
GFA
15 days from payment of fees
How long does it take for the Issuance of permits?
20%
How many percent is the open space for A,B,C D and K occupancies for Inside Lot
15
How many years is the accountability of an engineer or architect upon completion of the building ?
from Grade line to the topmost portion of the building
How to measure the building height? from Grade line to the topmost portion of the building from Grade line to the topmost portion of the building sigange from Grade line to the topmost portion of the building Antenna
C1
Light Commercial with Low-rise buildings (1-3 storeys)
MAXIMUM ALLOWABLE CONSTRUCTION AREA
MACA
750mm
Minimum width of the Stairs:
ROW
No building shall be constructed unless it adjoins or has direct access to a public space, yard, or street on at least one of its sides. ROW Eaves over window park Sidewalk
OUTER FACES OF THE BUILDING
OFB
Buildings
Occupancies are assigned to______________.
Department of Public Works and Highways
Who are the General administrator and enforcer of the building code?
DPWH Secretary
Who is responsible for collecting fees?
PROMENADE
a place specifically intended for walking
true
an abutment up to 3.20m high is OK for carports provided that above 1.50m, the abutment shall be constructed of perforated concrete blocks. True False
ESPLANADE
any open, level space, especially one serving for public walks or drives.
R3
belongs to High-density residential zone. Characterized low-rise or medium-rise buildings for use as multiple family dwellings Includes low-rise or medium-rise condominium buildings
4.50m x 2.00m x 2.00m
for R-1 occupancy what is the minimum setback?
USA + ISA
in computing the TOSL what is the formula?
PLANTING STRIP
is meant to separate the curb from the sidewalk, and must always be placed near the curb line.
ARCADES
may be constructed on sidewalks of streets whenever allowed or required by existing building and zoning regulations.
Corner Lot
10% open space required for A, B,C ,D and J Occupancies?
End lot
30-50% open space required for A, B,C D,E and H occupancy
C3
.Large to very large shopping malls , with very high intensity trade, normally 3-5 storey height.
2.5mW x 5.00mL
.Standard Parking Slot size for a Car in perpendicular parking
FIREWALL
A fireproof barrier used to prevent the spread of fire between or through buildings
Firewall
A fireproof barrier used to prevent the spread of fire between or through buildings
16
A proposed Public Hospital in Misamis Oriental can accommodate 400 patients both inpatient and outpatient. As a designer how many car slot should be provided or considered?
ANCILLARY BUILDING STRUCTURE
A secondary building/ structure located within the same premises, the use of which is incidental to that of the main building/structure
Policy making and Memorandum circulars Prescribe fees Appoint building officials in all municipalities
Duties of Secretary of the DPWH includes:
Interior Lot
E,F,G,H and I occupancies required 20%
ROOFTOP
ESTABLISHING THE TOP OF BUILDING : If roof is flat, top =
Group C
Education and Recreation are identified and classified as _______.
FLOOR AND LOT AREA RATIO
FLAR
Fire Zone 3
Fire Zones- under what zone where Type 1-3 of Construction is not allowed
2 sides, Maximum 85% of each side, Total should not exceed 50% of lot perimeter
Firewall for R4 which of the following statements below is true. 2 sides, Maximum 85% of each side, Total should not exceed 50% of lot perimeter 2 sides, Maximum 75% of each side, Total should not exceed 50% of lot perimeter 2 sides, Maximum 50% of each side, Total should not exceed 50% of lot perimete
for every 50 sqm of congregation area: 1 car slot and 1 jeepney slotslot
For Churches the parking requirement is.
1 slot for every 3 rooms
For Hotels in a highly urbanized area, the parking requirement is.
50%
For a R4 Zone firewall provision, what is the maximum allowable percentage for lot perimeter?
75%
For a R5 Zone under 2 side option firewall provision, what is the maximum allowable percentage for each side?
R4
Townhouse is classified as _________.
UNPAVED SURFACE AREA
USA
Maximum 80% of lot perimeter
Under Commercial, institutional, and industrial, firewalls allowed on the ff conditions below except 1. Provide sprinkler system Maximum 80% of lot perimeter Install fire-retardant or fire-suppression devices RROW setbacks are complied with
9 storey
Under R5 firewall configuration, below are the no. of storey allowed , except for 1. 8 Storey 3 Storey 2 storey 9 storey
Minor Constructions , repair works , Minor structure of 6sqm or less detached from other building , for private use only.
Under Rule 3 of PD 1096, When is the building permit is exempted?
R2
Under allowable firewalls, refers to one side only wiht a maximum 80% of the length of side property line. R2 R3 R4 R5
True
Under mixed occupancies, it is exempted If the minor occupancy does not exceed 10% of the building, in which case it is ignored True False
Industrial- workshops using incombustible and non-explosive materials, and storage and sales rooms for incombustible and non-explosive materials.
What are the occupancies under Group F?
Interior Lot, Inside Lot, Through Lot, Corner Through Lot, Corner Through Lot abutting 3 or more streets, alleys, rivers etc. , End Lot
What are the seven lot types
YARD
the required open space left between the outermost face of the building and the property lines
SETBACK
the width of the yard