Theory 2 Final

Lakukan tugas rumah & ujian kamu dengan baik sekarang menggunakan Quizwiz!

If the protection device is not rated to interrupt the current at the available fault values at its listed voltage rating, it could explode while attempting to clear the fault.

true

In the ac induction motor, the stator produces a rotating magnetic field that induces current in the rotor windings. The rotor current generates a magnetic field in opposition to the magnetic field of the stator, thereby causing the rotor to turn.

true

Metal parts of premises wiring must be bonded to a low-impedance path designed so that the circuit protection device will quickly open and clear a ground fault.

true

Severe electric shock or death can occur if a person touches the ungrounded and the neutral conductors at the same time, even if the circuit is GFCI-protected.

true

The current flowing on a neutral conductor of a multi wire branch circuit is called unbalanced current.

true

The energy transfer ability of a transformer is accomplished because the primary electromagnetic lines of force induce a voltage in the secondary winding.

true

The heating from harmonic currents is proportional to the square of the harmonic current.

true

Typically, when a GFCI protection device fails, the switching contacts remain closed and the device will continue to provide power without GFCI protection.

true

Unsafe arcing faults can occur in one of two ways, as series arcing faults or as parallel arcing faults. The most dangerous is the parallel arcing fault.

true

Voltage induced in the secondary winding of a transformer is dependent on the number of secondary turns as compared to the number of primary turns.

true

beer

true power (kW)

Swapping ______of of the line conductors can reverse a three-phase ac motor's rotation.

two

When describing the relationship between voltage and current, the reference waveform is always _______.

voltage

Factors that impact the available short-circuit current include transformer

voltage, KVA rating, impedance

Three-phase ac generators have three equally spaced windings______ out-of-phase with each other.

120 degrees

If the output is 1,600W and the equipment is 88 percent efficient, what are the input amperes at 120V?

15 A

What size transformer is required for a 100A, 240V, single-phase noncontinuous load that has a power factor of 85%

24,000VA/85% = 25kVA

how many 20A 120V circuits are required for forty two, 300W luminaire's (noncontinuous load) that have a power factor of 85%?

2400VA/(300W/85%)= 6 lights per circuit... 42(lights total)/6(lights per cicuit) = 7 circuits

If the primary phase voltage is 480V and the secondary phase voltage is 240V, the turns ratio is _____

2:1

Three-phase,____, wye connected systems can overheat because of circulating odd triplen harmonic currents.

4 wire

Arcing is defined as a luminous discharge of electricity across an insulating medium. Electric arcs operate at temperatures between _____ and expel small particles of very hot molten

5,000 and 15,000 degrees

What is the nameplate FLA for a 20 hp, 208V, three-phase motor with 90 percent power far and 80 percent efficiency?

58A

When a motor starts, the current drawn is approximately_______ times the motor FLA; this is known as motor locked-rotor amperes (LRA).

6

The induced voltage in a conductor carrying alternating current opposes the change in current flowing through the conductor. The induced voltage that opposes the current flow is called

CEMF, conter-electromotive force, back EMF

If the rotating part of the motor winding is jammed so that it cannot rotate, no CEMF will be produced in the motor winding. Result the motor operates at ______ and the windings will be destroyed by excessive heat.

LRC

In a(n)____ motor, the rotor is locked in step with the rotating stator field and is dragged along at the speed of the rotating magnetic field

Synchronous

______ motors are fractional horsepower motors that operate equally well on ac and de and are used for vacuum cleaners, electric drills, mixers, and light household appliances.

Universal

Self-induced voltage opposes the change in current flowing in the conductor. This is called inductive reactance and it is abbreviated ______.

XL

The opposition offered to the flow of ac current by a capacitor is called capacitive reactance, which is expressed in ohm and abbreviated

Xc

The abbreviation for impedance is

Z

Beer Glass

apparent power (kVA)

_____ can be reduced by dividing the core into many flat sections or laminations.

eddy currents

For ac circuits, the ac _____ of a conductor must be taken into consideration.

eddy currents, skin effect, resistance

A GFCI protection device contains an internal monitor that prevents the device from being turned on if there is a neutral-to-case connection downstream of the device, but this only occurs if there is a load on the circuit.

false

AC inductive or capacitive reactive loads cause the voltage and current to be in-phase with each other.

false

Available short-circuit current is the current in amperes available at a given point in the electrical system.

false

Inverse time breakers operate on the principle that as the current decreases, the time it takes for the device to open decreases.

false

The motor FLA rating is used when sizing motor conductor size or circuit protection.

false

To prevent fires and electric shock, the NEC specifies that neutral current can flow on metal parts of the electrical system.

false

Because of the dangers associated with an open neutral conductor, the continuity of the ___ conductor cannot be dependent upon the receptacle.

grounded

A GFCI is designed to protect persons against electric shock. It operates on the principle of monitoring the imbalance of current between the circuit's ______ conductor

grounded and ungrounded

As current flows through the transformer, the iron core is temporarily magnetized. The energy required to realign the core molecules to the changing electromagnetic field is called ______ loss

hysteresis

Wasteful circulating _____ in the iron core cause(s) the core to heat up without any useful purpose.

hysteresis losses

The total opposition to current flow in ac circuits is called _____ and measured in ohm.

impedance

Transformers are rated in

kVA

Factors that impact the available short-circuit current include circuit conductor

material, size, length

A non-sinusoidal waveform is created when ______ loads distort the voltage and current sine wave.

nonlinear

To protect against electric shock or to prevent a fire, a dangerous _____ must quickly be removed by opening the circuit's overcurrent protection device.

overload, short circuit, and ground fault

The purpose of overcurrent protection is to protect the conductors and equipment against excessive or dangerous temperatures because of overcurrent. Overcurrent is current in excess of the rated current of equipment or conductors. It may result from a(n).

overload, short current, or ground fault

Improper Wiring or Mishandling of multiwire Branch Circuits can cause ___ connected to the circuit.

overloading of the neutral and ruining equipment due to over voltage

Dual-voltage ac motors are made with two field windings. The field windings are connected in _____for low-voltage operation and in ______for high-voltage operation.

paralell, series

Because of the earth's high resistance to current flow, it cannot be used for the purpose of clearing a line-to-case ground fault for______ wiring.

premesis

foam

reactive power (kVAr)

The______ of an ac generator contains the electromagnetic field, which cuts through the stationary conductor coils

rotor

Equipment must have a(n)____ current rating that permits the protection device to clear a short circuit or ground fault without extensive damage to the components of the circuit.

short circuit

The magnetic time-delay circuit breaker operates on the solenoid principle where a movable core, held with a spring, is moved by the magnetic field of a(n) ______

short circuit or ground fault

The expanding and collapsing magnetic field within the conductor induces a voltage in the conductors (CEMF) that repels the flowing electrons toward the surface of the conductor. This is called ______.

skin effect

The sensing element causes the circuit breaker to open when a predetermined calibration temperature is reached.

thermo

The effective value is equal to the peak value_____.

times .707

An AFC protection device provides protection from an arcing fault by recognizing the characteristics unique to an arcing fault and by functioning to de-energize the circuit when an arc fault is detected.

true

Because of conductor resistance, flux leakage, eddy currents, and hysteresis losses, not all of the input power is transferred to the secondary winding for useful purposes.

true

Circuit breakers and fuses are intended to interrupt the circuit, and they shall have an ampere interrupting rating (AIR) sufficient for the available short-circuit current

true

Electrons leaving a power supply are always trying to return to the same power supply; they are not trying to go into the earth.

true

Even when power is removed from the circuit, capacitors can store large amounts of energy for a long period of time. They can discharge and arc if inadvertently shorted or grounded out.

true


Set pelajaran terkait

Mat 17 The Czech Republic, sightseeing, Prague and other places of interest | Maturita SUPŠ Helenín

View Set

Intermediate Accounting 1 Chapter 6

View Set

Holt, Electricians Exam Prep Unit 1

View Set

I. True or False Statement- Write "TRUE" if the statement is TRUE. Write "FALSE" if the statement is FALSE (5 Point).

View Set

Combo with "Evolve : Adolescents" and 5 others

View Set