6A
Category _____ or higher is recommended for horizontal cabling
Class 1
Class _____ address the needs of the premises served by a single ER, which is the only telecommunications space on site
Class 3
Class _____ addresses infrastructure with multiple buildings at a single site (e.g., campus environment)
568.1
Commercial Building Telecommunications Infrastructure Standard
6
Fall protection is required whenever a person is exposed to a fall hazard to another level of more than _____ feet
5e
For all new installations, multi pair backbone meet the minimum performance of category _____ cable
568.0
Generic Telecommunications Cabling for Customer Premises
Stranded
IPCs can be used for __________ cables
Resistance, Capacitive Reactance, and Inductive Reactance
Impedance is the combined affect of __________, __________, and __________
Impedance
In AC circuits, the total opposition to current flow is called __________, which is measure in ohms
NEC
In North America and many other regions, the code most commonly encountered is the __________
Star
In the _____ topology, the network switch is placed in the physical as well as the logical center of the network
568.3
Optical Fiber Cabling components standard
Black
Pair 1440 would be in the __________ Super Binder
Black/Blue
Pair 267 is in the __________ binder
Violet/Brown
Pair 600 is in the __________ binder group
Red
Pair 626 would be in the __________ Super Binder
55
Personnel should not lift a load in excess of _____ lbs per person
Electrical Shock, Falling or Flying Objects, and A Blow to the Head
Protective headgear (hard hats) protect the installer from __________, __________, and __________
5e
The horizontal cabling provided to each individual work area shall consist of telecommunications outlet/connectors connected to category _____
1/4
The horizontal distance from the base of the ladder to the supporting wall should be _____ the working length of the ladder
TP
The interconnection point between horizontal cabling and UTC
16.5 feet
The maximum equipment cord length in the work area
Insertion Loss (Attenuation)
The measure of signal loss resulting from the insertion of a component, link, or channel between a transmitter and receiver
100
The nominal characteristic impedance of balanced twisted pair cable is _____ ohms at 100 MHz
Nominal Velocity of Propagation (NVP)
The ratio speed of transmission along a cable relative to the speed of light in a vacuum
Alien Crosstalk (AXT)
The unwanted signal coupling from a disturbing pair of a 4-pair cable channel, permanent link, or component to a disturbed pair of another 4-pair channel, permanent link or component. The disturbed pair is sometimes referred to as the "victim cable"
4P4C
These connectors are primarily used for handset cords
8P8C
These connectors are used for ICT equipment and patch cords
6P6C
These connectors are used primarily for telephones and modem lines
N and BNC
These connectors both have center pins
568.4
Broadband Coaxial Cabling and Components Standards
5,000
A PFAS included a full-body harness, a shock-absorbing lanyard, and a secure anchorage point capable of supporting __________ lbs
3,600 Feet Squared
A TE can serve a maximum of __________
Intermediate Cross-Connect
A __________ connects 1st level backbone to 2nd level backbone
Interconnection
A __________ connects a cable to an active component
Telecommunications Room (TR)
A __________ is an enclosed architectural space for housing telecommunications equipment, cable terminations, and cross-connect cabling
Telecommunications Room (TR)
A __________ typically serves one floor of a building or a portion of a floor
6
A gauge change of ____ numbers approximately doubles or halves the conductor's diameter
3
A gauge change of ____ numbers approximately doubles or halves the conductor's resistance
3
A gauge change of _____ numbers approximately doubles or halves the conductor's cross-sectional area
Near-End Crosstalk (NEXT)
A measure of the unwanted signal coupling from a transmitter at the near end into another pair measure at the near end
2
A minimum of _____ telecommunications outlet/connectors is recommended per work area
ANSI
A private, not-for-profit organization that serves as the administrator and coordinator of the United States' private sector voluntary standardization system
Inductance
A property of an electromagnetic field built around a conductor that opposes any change in current flow in a circuit
Purple
The color field for the "Common Equipment" terminations field is _____
Orange
The color field for the "Demarcation Point" termination field is _____
Brown
The color field for the "Interbuilding Backbone Cable" termination field is _____
Yellow
The color field for the "Miscellaneous" termination field is _____
Green
The color field for the "Network" termination field is _____
Red
The color field for the "Reserved" termination field is _____
Horizontal Cross-Connect (HC) or Floor Distributor (FD)
The connection between the Horizontal cable and the Backbone cable is called __________
Survey the scene ( "THE SCENE IS SAFE")
The first of the six basic steps to safely assist others without endangering yourself is __________
500 MHz
The frequency of a Category 6a cable
2000 MHz
The frequency of a Category 8 cable
2 to 3
__________ milliamperes produce a tingling of the skin
100
__________ milliamperes trigger ventricular fibrillation, which causes the heart to repeatedly relax and violently clamp shut
TSB 36
__________ was issued in 1991 to address categories
TSB 40
__________ was issued in 1992 for connectors
TIA/EIA 568
__________ was the first cabling standard. No categories were specified and connectors were not addressed
Capacitance
A property of conductors that allows storage of electrical charges when potential differences (voltages) exist between the conductors
Return Loss
A ratio of the power of the outgoing signal to the power of the reflected signal and is expressed in decibels
Code
A rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related subjects
100
A typical work area is _____ feed squared
607
ANSI/TIA-_____ says that structural metal should be tested to verify its conductivity to earth
570
ANSI/TIA-_____ standardizes requirement for residential telecommunications cabling
Manufacturer's Instructions
According to the Hierarchy of Compliance Pyramid, __________ should be at the bottom
Authority Having Jurisdiction (AHJ)
According to the Hierarchy of Compliance Pyramid, __________ should be at the very top
Standard
An accepted collection of requirements and recommendations for the defining, constructions, evaluation, applications, or comparison of materials, equipments, products, and services
Regulations
An authoritative rule that controls or governs behavior leading to uniformity
DIN VDE
An example of the electrical code of Germany
BS 7671
An example of the electrical code of the United Kingdom
800
Article _____ says that communication wires and cables shall be listed
Coax
Between Coax and Twisted Pair, which has the highest bandwidth?
11
Series _____ is the preferred choice for longer runs
10
Stay at least _____ feet away from exposed energized electrical conductors, such as wires or crane bus bars, operating at 300 - 50,000 volts
False
T/F: Crosstalk values are typically a positive value
True
T/F: In the American Wire Gauge (AWG) system, smaller numbers equal larger wires and larger numbers equal smaller wires
True
T/F: Much like codes, regulations, once adopted by jurisdiction, are considered mandatory, and are typically enforced by some level of government
True
T/F: There are five colors associated with tip conductors
TSB 67
Testing first appeared in 1995 in __________. For 4 years, if you relied on the standards, you could install category 5 cable without testing
Airway
The "A" in "ABC" stands for __________
Confine
The "C" in "RACE" stands for __________
Interbuilding and Intrabuilding
The 2 difference "types" of backbone cabling are _________ and __________
Bus
The _____ topology is a linear configuration that places all of the network devices on one length of cable
Tree
The _____ topology is an extension of the bus topology
Star
The _____ topology is the required topology for structured cabling systems (SCS)
Violet/Slate
The __________ binder group is not used
Intermediate Cross-Connect (IC) or Building Distributor (BD)
The __________ is a building serving cross-connect that serves as the connection between two backbone cables
Main Cross-Connect (MC) or Campus Distributor (CD)
The __________ is housed in the ER and connects the entrance cabling, backbone cabling, and equipment cabling
AHJ
The __________ is responsible for enforcing the codes and legal regulations for the jurisdiction
White/Orange (Pin 3) Orange White (Pin 6)
The __________ pair is on pins 3 and 6 when using 568A
Labeling, Records, and Identifiers
The administration systems for each class include requirements for __________, __________, and __________
Industry Best Practices
Vendor-neutral methods that are widely used and accepted in a given industry because they have consistently shown superior results to those achieved through other means
Yellow/Orange
What color is pair 267?
606
You would look in ANSI/TIA-_____ if you needed information on the labeling standard
Manufacturer's Instructions
__________ are used by the manufacturer to list performance and technical characteristics for a given product
Horizontal
__________ cabling is the portion of the telecommunications cabling system that connect the work areas to the other telecommunications spaces
50-100
__________ milliamperes cause breathing to become difficult
10
__________ milliamperes produce a painful shock, and the muscles cannot release the contact