If a motor has 4 poles and is operating at a frequency of 60Hz its synchronous speed is

1,800 RPM

A motor a with a NEMA kVA code letter of of M has a locked-rotor value of

10.0-11.19kVA/hp

Per NEC Section 430.32,a motor with a service factor of 1.0 must trip at

115%of the full load current

The rpm of a 60Hz motor with two poles is

3,600

The electrical energy required to produce 1hp of mechanical energy is

746W

When variable-frequency speed control is used on a motor with a nameplate rating of 480V at 60Hz the voltage-to-frequency ratio is

8

Most industrial motors are NEMA Design

A

Using NEMA frame designations, the distance from the motor feet to the shaft center line is known as the

D dimension

Reconnecting a running motor to act as a generator is known as

Dynamic braking

The NEMA frame designation for gasoline pump motor is

G

The code requiremnts for motor disconnects are coveredin

NEC Articles 430 part IX

The speed of an induction motor depends on the power supply frequency and the

Number of poles

A motor with the field coils connected in parallel with the rotor winding is a

Shunt Motor

In three phase motors, the rotor most commonly used is the

Squirrel cage rotor

To product the motr from overloads and starting failures use a

Thermal protector

A three-phase synchronous motor is started with an

amortisseur winding

The name of the motor part that rotates during operation is the

armature/rotor

To determine the horsepower rating of a motor that is already installed and in place

check the nameplate data

When Studying the operation of electric motors, it is important to remember that magnetic lines of force

do not cross

When using a motor with dynamic braking

electromechanical friction brakes may be required with large loads

The principal reasons for developing the brushless DC motor was to

eliminate commutator problems

A NEMA designation for a type of enclosed motor is

explosion-proof

The letters FLA on a motor name plate stand for

full-load amps

The two primary types of motor of motor enclosures classified by NEMA are

general purpose and guar

The method of braking in which DC is applied to the motor windings after AC is removed is known as

injection braking

Any exposed live parts of motors must be guarded if the motor

operates at 50V or more between terminals

An open AC squirrel cage motor that makes use of form-wound coils and an insulation system is known as an

semi-guarded

When there is a wide variation in both torque and speed requirements, such as a blower or a hoist, use a

series DC motor

The multiplier to the nameplate horsepower rating is called the

service factor

A heating system is most likely to use a

single-phase induction motor

The speed on a multiple winding motor is normally changed by

switching contacts in a motor controls

A type of motor used in precision applications that require constant speed with zero slip is a

synchronous

A delta-connected motor has

the coils connected in parallel

A wye-connected motor has

the coils connected in series

With a constant -torque load , the horsepower

varies in direct proportion to the speed