Building Code (PD 1096) Rule VIII -XX

Ace your homework & exams now with Quizwiz!

Minimum side and rear setbacks for commercial, industrial, institutional and recreational building having 10 - 19 meters RROW.

2 meters

Minimum ceiling height for natural ventilation.

2.70 meters

Street, alleys, easements of sea/lakeshores, rivers, creeks, esteros, railroad tracks, parks/plazas, playgrounds, and the like.

Public Open Space

Abutments shall be allowed on only one (1) side for any ______ lot type/location.

R-2

There shall be no firewalls/abutments on the front and rear property lines for any _______ lot type/location.

R-2

Abutments shall be allowed on two (2) sides only or on one (1) side and the rear property line/boundary for any ______ lot type/location.

R-3

Abutments shall be allowed on two (2) sides only or on one (1) side and the rear property line/boundary for any _____ lot type/location.

R-3, R4, R5, C3

There shall be no abutments on the front property line for any _______ lot type/location.

R-3, R4, R5, C3

Abutments shall be allowed on two (2) sides only for any ____ lot type/location.

R-4

Mixed-use building/structures in ______ lots may be considered a commercial development if a substantial percentage of the GFA is commercial.

R-5

PSO + TOSL

TLA

Courts, yards, gardens, light wells, uncovered driveways, access roads and parking spaces.

TOSL

A __________shall not be considered part of the TOSL within lot particularly if it is entirely roofed or roofed with overhangs.

carport

Minimum road right-of-way provisions for developments with multiple dwelliing units having more than thirty-five (35) units.

8.70 meters

Minimum easement wide for esplanade development.

9.0 meters

Occupancies or group of building occupancy that shall follow the minimum yards standards.

Group A (R-1)

PSO + ISA

MACA

Paved or tiles (hardscaped areas); sub-classification of open space shall fall under the _________ within the TLA.

Maximum Allowable ISA

The required open space left between the outermost face of the building/structure and the property lines.

Yard

A front yard may be partly paved/hardscaped to serve as a carport but only for a __________ use or occupancy, i.e., all for single-family dwelling units only.

basic R-2, basic R-3 or R-4 (individual lot)

No building shall be constructed unless it adjoins or has direct access to public space, yard or street/road on at least _______of its sides.

one

Minimum total width of planting strips within 10 - 19 meters RROW.

0.40 (0.20) meters

Minimum total width of planting strips within 20 - 29 meters RROW.

0.60 (0.30) meters

Minimum dimension of a vent shaft.

0.60 meter

Minimum width of window clear opening for emergency egress.

0.82 meters

Maximum height of the bottom of the window opening use as for emergency egress.

0.82 meters from the floor

Minimum dimension of bath and toilet.

0.90 meter

Minimum height of window clear opening use as for emergency egress.

1.0 meter

Minimum cross-sectional area of ventilation or vent shaft.

1.0 sqm

Minimum window opening area not provided with artificial ventilation system.

1.0 sqm

Minimum area for school rooms per person.

1.00 sqm

Minimum total width of planting strips within 30.0 meters and above RROW.

1.20 (0.60) meters

All inner courts shall be connected to a street or yard, either by a passageway with a minimum width of _______ meters or by a door through a room or rooms.

1.20 meters

Maximum width of roof ladders, wall copings, sills or steel fire escapes.

1.20 meters

Minimum width of sidewalks for a RROW width of 9.0 meters.

1.20 meters

Minimum area of bath and toilet.

1.20 sqm

Minimum dimension of kitchen.

1.50 meters

Minimum height of a mezzanine.

1.80 meters

Open space requirements for cornet lot.

10%

Open space requirements for through lot.

10%

Minimum window total free area of openings for rooms not provided with artificial ventilation.

10% of the floor area

Minimum air space requirements for workshop, factories and office per person.

12.0 cum

Minimum air space requirements for habitable rooms.

14.0 cum

Minimum side and rear setbacks for commercial, industrial, institutional and recreational building having 10 meters and below RROW.

2 meters

Minimum width of alley/carriageway for 3.0 meters ROW.

2 meters

Minimum dimension of rooms for human habitation.

2.0 meter

Minimum dimension of a courts and yards.

2.0 meters

Maximum height of separation walls or fences.

2.00 meters

Minimum ceiling height for habitable rooms for succeeding floors above second floor.

2.10 meters

Minimum ceiling height for habitable rooms for the second storey.

2.40 meters

Minimum ceiling height for habitable rooms provided with artificial ventilation.

2.40 meters

Minimum ceiling height for habitable rooms at the ground floor.

2.70 meters

Minimum ceiling height having windows that is open to roofed porch.

2.70 meters

Open space requirements for inside lot.

20%

Minimum easement of agricultural areas to the location of water body.

20.0 meters

Minimum window opening area not provided with artificial ventilation.

244 sq. mm

Minimum front setback of basic R-2

3 meters

Minimum front setback of basic R-3

3 meters

Minimum side and rear setbacks for commercial, industrial, institutional and recreational building having 20 - 29 meters RROW.

3 meters

Minimum air space requirements for school rooms per person.

3.0 cum

Minimum access road of turn court and cul-de-sac.

3.0 meters

Minimum access width for six (6) units.

3.0 meters

Minimum easement of urban areas to the location of water body.

3.0 meters

Minimum side and rear setback of basic R-5

3.0 meters

Minimum width of RROW/access street for interior or rear lots.

3.0 meters

Court may be reduced to 1.50 meters in cluster living units such as quadruplexes, rowhouse and the like, with adjacent courts with an area of not less ___________ sqm.

3.0 sqm

Minimum area of kitchen.

3.0 sqm

Open space requirements for interior lot.

30%

Open space requirements for end lots.

30-50%

For buildings or more than two (2) storeys in height, the minimum width of the rear or side court shall be increased at the rate of _______mm for each additional storey up to the fourtheenth (14th) storeys.

300 mm

Minimum depth of firewall below eaves.

300 mm

Minimum width of carriageway for 6.0 meters RROW.

4.0 meters

Minimum width of chaflan that intersect with the main RROW.

4.0 meters

Minimum road right-of-way provisions for developments with multiple dwelliing units having up to six (6) units

4.20

The minimum clear height for the utilization of the air rights above RROW shall be ______meters from the finished crown elevation of the roadway/carriageway.

4.27 meters

Minimum front setback of R-1

4.50 meters

Minimum front setback of R-4

4.50 meters

Minimum easement of forest areas to the location of water body.

40.0 meters

Minimum height clearance of firewall above roof.

400 mm

Minimum front setbacks for commercial, industrial, institutional and recreational building having 10 - 24 meters RROW.

5 meters

Minimum front setbacks for commercial, industrial, institutional and recreational building having 10 meters and below RROW.

5 meters

Minimum side and rear setbacks for commercial, industrial, institutional and recreational building having 30 meters and above RROW.

5 meters

Open space requirements for corner-lot abutting 3 or more streets, alleys, rivers, etc.

5%

Open space requirements for corner-through lot.

5%

Minimum window total free area of openings for toilet and bath not provided with artificial ventilation.

5% of the floor area

Minimum front setback of basic R-5

6 meters

Minimum front setbacks for commercial, industrial, institutional and recreational building having 25 - 29 meters RROW.

6 meters

Minimum road right-of-way provisions for developments with multiple dwelliing units having seven (7) up to fifteen (15) units.

6.0 meters

Minimum area of rooms for human habitation.

6.0 sqm

Minimum width of firewall along party wall.

600 mm

Minimum road right-of-way provisions for developments with multiple dwelliing units having seven (16) up to fifteen (25) units.

7.0 meters

Minimum eaves, canopies, awnings from the side and rear property lines.

750 mm

Minimum front setback of max R-2

8 meters

Minimum front setback of max R-3

8 meters

Minimum front setbacks for commercial, industrial, institutional and recreational building having 30 meters and above RROW.

8 meters

Minimum road right-of-way provisions for developments with multiple dwelliing units having seven (26) up to fifteen (35) units.

8.0 meters

Absolutely no abutments are allowed at any property line for _____ lot type/location.

R-1

Minimum dimension of an air duct.

0.30 meter

Minimum cross-sectional area of air ducts.

0.30 sqm

Unpaved areas within the lot that are with exposed soil and planted (softscaped).

USA


Related study sets

Intro to Business Managing a Business and Employees

View Set

Chapter 22: School Health Nursing

View Set

Chapter 3: The Role of the Project Manager

View Set

Ch. 6: identifying market segments and targets

View Set

OB Module 2: Care of the Pregnant Woman

View Set