By definition, an attachment fitting is different from an attachment plug because no ___ is associated with the fitting

Cord

MULTI WIRE BRANCH CIRCUIT

A branch circuit consisting of two or more grounded conductors having a potential difference between them, and a grounded conductor having equal potential difference between it

Composite optical fiber cables contain optical fibers and

Current-carrying electrical conductors

The ____ of any system is the ratio of the maximum demand of a system, or part of a system, to the total connected load of a system

Demand factor

Systems of illumination utilizing fluorescent lamps, high-intensity discharge lamps or neon tubing are all types of

Electric discharge lighting

Surrounded by case, housing, fence, or walls that prevents persons from accidentally contacting energized parts is called

Enclosed

The installed conductive paths that is part of a ground fault current path and connects normally no current carrying natal parts of equipment together and to the system grounded conductor or to the grounding electrode or both is known as _______ conductor

Equipment grounding

Examples of ground-fault current paths include any combination of conductive materials including

Equipment grounding conductors, metallic raceways, and metal water and gas piping

Connected to ground or to a conductive body that extends the connection is called _______

Equipment grounding, bonded, and grounded

A _____ is an accommodation that combines living, sleeping, sanitary, and storage facilities within a compartment

Guest room

A branch circuit that supplies only one utilization equipment is a(n) ____ branch circuit

Individual

Due to its power limitations, a class 2 circuit considers safety from a fire initiation standpoint and provides acceptable protection from electrical shock

True

A battery system includes storage batteries and battery chargers, and can include inverters, converters, and associated electrical equipment.

True or False

The generating capacity, inverter is the sum of parallel-connected inverter maximum continuous output power at 40 Celsius in

Watt or kW

An effective ground fault current path is an intentionally constructed, low-impedance electrically conductive path designed and intended to carry current during a ground-fault condition from the point of a ground fault

Ground

A conducting object through which a direct connection to earth is established is a ______

Grounding electrode

A conductor used to connect the system grounded grounded conductor or the equipment to a grounding electrode or to a point on the grounding electrode system, is called the ______ conductor

Grounding electrode


Related study sets

Chapter Eleven Psych Assignment Quizlet:

View Set

Ch. 13 Parents by Adoption and ART

View Set

WEEKS 3,4,5 QUIZ: INTRAPARTAL COMPLICATIONS, THERAPEUTIC MGT, BLEEDING DISORDERS, POSTPARTUM COMPLICATIONS

View Set

Chapter 44: Digestive and Gastrointestinal Treatment Modalities 1

View Set

Maternal Newborn Practice Questions

View Set