HVAC CLASS 2336
Check valves that open insufficiently will
Act as a throttling device and create a pressure drop
A liquid line filter-drier needs to be replaced when ____
Both A and B
Bubbles in a sight glass may indicate ___
Both A and B
On heat pumps, each bypass line around a metering device usually contains a ___
Check valve
A valve with an adjustable pressure setting that prevents compressor inlet pressure from exceeding a preset safe value is a ____
Crankcase pressure regulator
A port containing a color-changing element used to indicate a system's moisture content is referred to as a moisture valve
False
A relief valve that consists of a metal core that melts at a much lower temperature than its outer shell is called a spring-loaded relief valve
False
Which of the following statements regarding off-cycle defrost systems is false?
It can only be used in very-low temperature systems.
The condenser pressure regulator closes when condenser pressure is
Less than the pressure exerted by the regulators adjustable spring
A single-body, combination condenser-receiver pressure regulator that regulates both condenser and liquid receiver pressures is a ___ control
Low-ambient
In what type of defrost system is air from the conditioned space circulated over the evaporator when the compressor is not running?
Off-cycle defrost system
Receiver pressure regulators
Open on a rise in pressure difference between a discharge line and a liquid receiver
Condenser pressure regulators and receiver pressure regulators are primarily use to ___
Raise high-side pressure
A condensate pump is used to ___
Remove the moisture that builds up from defrosting and condensation
After a compressor burnout, temporarily install a new ____ to protect the compressor for the duration of the cleanup
Suction line filter drier
After a compressor burnout, temporarily install a new ___ to protect the compressor for the duration of the cleanup
Suction line filter- drier
The color-changing element in a moisture indicator is designed to change color based on ___
The amount of moisture in the refrigerant
A small viewport installed in a refrigerant line is a sight glass
True
shutoff valves are designed so that they can be operated by hand
True
some commercial refrigeration applications require that water be kept from freezing at temperatures below 32F (0C)
True
A condenser that uses only the air movement of either natural convection or forced drafts to remove heat from a system's refrigerant is a(n) ___ condenser
air-cooled
In a nonfreezing solution defrost system, ___
all of the above
Solenoid valves are controlled by ___
an electric signal
surfaces in and along air ducts that direct airflow through the evaporator and throughout the cabinet are called
baffles
Valves that are used to permit flow in only one direction are ___
check valves
Valves that are used to permit fluid flow in only one direction are ___
check valves
Refrigerant line valves on a commercial refrigeration system ___
control the flow of refrigerant through system piping
A valve used to direct liquid refrigerant from the liquid line to combine with hot gas and provide a cooler refrigerant mixture into the low side is a ___
crankcase pressure regulator
an electric heat defrost system ___
energizes electric heating coils
A relief valve that consists of a metal core that melts at a much lower temperature than its outer sell is called a spring-loaded relief valve.
false
An off-cycle defrost system can only be used if the air in the conditioned space remains within five degrees of freezing
false
Relief valves should only be inspected every six to twelve years
false
Valves that enable technicians to access a system to add refrigerant, take pressure measurements, and perform other procedures are called check valves.
false
Heat exchangers featuring metal fins of various styles and types connected to evaporator tubing are ___ evaporators.
find-and tube
The condenser pressure regulator and receiver pressure regulator work together to maintain head pressure on the ___
high side of the system in low outdoor temperatures
page 17
left of
A single-body, combination condenser-receiver pressure regulator that regulates both condenser and liquid receiver pressure is a ___ control
low-ambient
An evaporator that depends on gravity for air circulation is a ___ evaporator
natural-draft
an evaporator that depends on gravity for air circulation is a ___ evaporator
natural-draft
In what type of defrost system is hot refrigerant gas diverted to the evaporator to expedite the defrosting process?
off-cycle defrost system
Heat exchangers made from two metal sheets that are welded together to form a series of passages are ___ evaporators.
plate
heat exchangers made from two metal sheets that are welded together to form a series of passages are ___ evaporators
plate
Relief valves are installed in a refrigeration system to
prevent equipment damage or personal injury by venting refrigerant
Relief valves are installed in a refrigeration system to ___
prevent equipment damage or personal injury by venting refrigerant
Condenser splitting is a method of head pressure control that makes use of ___
reduced volume
condenser splitting is a method of head pressure control that makes use of ___
reduced volume
A condensate pump is used to ___
remove the moisture that builds up from defrosting and condensation
A condenser in which a water tubing winds around the inside of a metal refrigerant shell is called a(m) ___ condenser.
shell-and-coil
A suction line-liquid line heat exchanger ___
superheats vapor refrigerant in the suction line
A suction line-liquid line heat exchanger ___.
superheats vapor refrigerant in the suction line
some type of water-cooled condensers use ___
the bottom part of the shell as a liquid receiver
A defrost timer that turns on defrost operations at a preset time and stops defrosting operations when the evaporator reaches a preset cut-out temperature is a ___ defrost timer
time-initiated, temperature-terminated
A defrost timer that turns on defrost operations at a preset time and ends the defrost operation at a preset time is a ___ defrost timer.
time-initiated, time-terminated
A riser is a length of horizontal refrigerant line
true
A rupture disc consists of a thin metal disc that bursts before the pressure in a system reaches dangerous levels
true
a sweet water bath is composed of 20% glycol and 80% tap water
true
air-cooling evaporators are used to directly cool the air within a conditioned space
true
closing the condenser housing louvers can be used to raise low head pressure in low ambient temperatures
true
some water defrost systems spray a lithium chloride brine solution over the evaporator
true
A liquid-cooling evaporator ___
uses a cooled liquid that acts as the primary heat transfer medium
In a hot-gas defrost system, the evaporator is defrosted by ___
warm liquid refrigerant from the high side
which of the following statements regarding water defrost systems is false
water delivery may be done during a cooling cycle with the compressor running
In a tube-within-a-tube condenser, ___
water enters the condenser at the point where the liquid refrigerant exits
A condenser that uses only water as the medium into which system heat is expelled is a(n) ___ condenser.
water-cooled