Building Laws
1.80 meters
BP 220: Minimum ceiling height for mezzanine?
2.00m
BP 220: Minimum ceiling height per floor?
1.80m
BP 220: DOOR Minimum height of Bathroom/Mezzanine?
General: 2.00m
BP 220: DOOR Minimum height?
0.60 m
BP 220: DOOR Minimum width of Bathroom?
0.70 m
BP 220: DOOR Minimum width of Bedroom?
0.80 m
BP 220: DOOR Minimum width of Main Door?
300mm - Above Roof 300mm - From Outermost Edges (Walls) 300mm - Under Eaves
BP 220: Firewall Extensions - Above Roof? - From Outermost Edges (Walls)? - Under Eaves?
Front Setback: 1.50m Side Setback: 1.50m Rear Setback: 2.00m Distance of eaves from property line: 0.75m
BP 220: LOCATION ON PROPERTY Front Setback? Side Setback? Rear Setback? Distance of eaves from property line?
2 Meters
BP 220: Light and Ventilation - Minimum dimension of court?
1.20 meters
BP 220: Light and Ventilation - Minimum width of court passageway?
5% of Floor Area
BP 220: Light and Ventilation - Windows for bathrooms?
10% of Floor Area
BP 220: Light and Ventilation - Windows for rooms?
800-1200mm
BP 220: Stairs - Handrail Height?
250mm maximum
BP 220: Stairs - Maximum Riser?
3.60m
BP 220: Stairs - Maximum Vertical Between Landings?
2.00m minimum
BP 220: Stairs - Minimum Headroom?
200mm minimum
BP 220: Stairs - Minimum Tread?
600mm
BP 220: Stairs - Minimum Width?
300mm-wide
BP 220: Stairs - Slanted nosing preferred over protruding nosing, provide _____ wide tactile strip at top and bottom of stairs.
2.00 M
BP 344: Minimum Ceiling Height for Walkways?
1.20 m
BP 344: Corridors?
820-1060 mm (900 preferred)
BP 344: DOOR Height of door knob?
2.00 m
BP 344: DOOR Minimum height?
0.80 m
BP 344: DOOR Minimum width?
700mm and 900mm
BP 344: Ramps - Handrail height?
6.00 m
BP 344: Ramps - Horizontal distance between landings?
1:12
BP 344: Ramps - Maximum Slope?
1.50 m
BP 344: Ramps - Minimum Landing Length?
1.20 m
BP 344: Ramps - Minimum Width?
1.10 m
PD 1096: Corridors?
1.20 m
PD 1096: DOOR Maximum width?
2.00 m
PD 1096: DOOR Minimum height?
0.90 m
PD 1096: DOOR Minimum width?
400mm - Above Roof 600mm - From Outermost Edges (Walls) 300mm - Under Eaves
PD 1096: Firewall Extensions - Above Roof? - From Outermost Edges (Walls)? - Under Eaves?
Front Setback: 4.50m R1 Side Setback: 2.00m R1 Rear Setback: 2.00m R1 Distance of eaves from property line: 0.75m
PD 1096: LOCATION ON PROPERTY (R1) Front Setback? Side Setback? Rear Setback? Distance of eaves from property line?
2 meters
PD 1096: Light and Ventilation - Minimum dimension of court?
1.20m
PD 1096: Light and Ventilation - Minimum width of court passageway?
5% of floor area, but 240 sq.mm minimum
PD 1096: Light and Ventilation - Windows for bathrooms?
10% of floor area, but 1 sq.m minimum
PD 1096: Light and Ventilation - Windows for rooms?
14.00 cubic meters
PD 1096: Minimum Air Space Requirements Habitable Rooms:
12.00 cubic meters
PD 1096: Minimum Air Space Requirements Office and Factories:
3.00 cubic meters (Allot 1.00 sqm per person)
PD 1096: Minimum Air Space Requirements Schools:
1.80 m
PD 1096: Minimum Ceiling Height for Mezzanine?
Ground Floor: Naturally Ventilated - 2.70m Artificially Ventilated - 2.70m
PD 1096: Minimum Ceiling Heights Ground Floor: Naturally Ventilated? Artificially Ventilated?
Second Floor: Naturally Ventilated - 2.70m Artificially Ventilated - 2.40m
PD 1096: Minimum Ceiling Heights Second Floor: Naturally Ventilated? Artificially Ventilated?
Succeeding Floors: Naturally Ventilated - 2.70m Artificially Ventilated - 2.10m
PD 1096: Minimum Ceiling Heights Succeeding Floors: Naturally Ventilated? Artificially Ventilated?
1.20 sqm minimum dimension of 0.90m
PD 1096: Minimum Room Sizes Bathroom? Minimum Dimension of?
3.00 sqm minimum dimension of 1.50m
PD 1096: Minimum Room Sizes Kitchen? Minimum Dimension of?
6.00 sqm minimum dimension of 2.00m
PD 1096: Minimum Room Sizes Rooms for human habitation? Minimum Dimension of?
800-900mm
PD 1096: Stairs - Handrail Height?
200 mm
PD 1096: Stairs - Maximum Riser?
3.60 m
PD 1096: Stairs - Maximum Vertical Between Landings?
2.00 m
PD 1096: Stairs - Minimum Headroom?
250 mm
PD 1096: Stairs - Minimum Tread?
For Rowhouse: 300mm - Above Roof 300mm - From Outermost Edges (Walls) 300mm - Under Eaves
PD 957: Firewall Extensions - Above Roof for Rowhouse? - From Outermost Edges (Walls) for Rowhouse? - Under Eaves for Rowhouse?
Front Setback: 4.50m Side Setback: 2.00m Rear Setback: 2.00m Distance of eaves from property line: 0.75m
PD 957: LOCATION ON PROPERTY Front Setback? Side Setback? Rear Setback? Distance of eaves from property line?
1.20 sqm minimum dimension: 0.90m
PD 957: Minimum Room Sizes Bathroom? Minimum Dimension of?
3.00 sqm minimum dimension: 1.50m
PD 957: Minimum Room Sizes Kitchen? Minimum Dimension of?
6.00 sqm minimum dimension: 2.00m
PD 957: Minimum Room Sizes Rooms for human habitation? Minimum Dimension of?
2.00 meters
RA 9514: Minimum ceiling height for means of egress?
1220 mm
RA 9514: DOOR Maximum width?
2.00 m
RA 9514: DOOR Minimum height?
710 mm
RA 9514: DOOR Minimum width?
760-865mm
RA 9514: Ramps - Handrail height?
1 in 48
RA 9514: Ramps - Maximum Cross Slope?
1 in 12
RA 9514: Ramps - Maximum Slope?
1120mm
RA 9514: Ramps - Minimum Width?
760mm
RA 9514: Ramps - Vertical distance between landings?