Altus EOC
Which switch is used for a normal APU start?
1
Which generator buses are the normal sources of power for the battery chargers?
1 & 4
Aircraft batteries can be fully recharged by the battery chargers in
1 hr
To which of the following pallet positions does the logistic rail system provide permanent vertical restraint?
1 through 6 and part of 7
When in operating position, the cable guide sheave allows the cable to extend ___________ above the floor.
1.0 inch
For planning purposes, how many 25,000 pound chains are needed for forward restraint on a vehicle which weighs 53,500 pounds?
10
For planning purposes, how many 10,000 pound chains are needed for aft restraint on a vehicle weighing 53,500 pounds?
12
After installing two symmetrical 25,000 pound tiedowns on a unit of cargo, you measure and record the following: Chain length 75 inches Longitudinal length 60 inches Lateral length 20 inches Vertical length 24 inches How much vertical restraint is provided?
16,000 lbs
Fuel dump above __________ feet may cause engine flameout due to loss of fuel pressure.
20,000
After installing two symmetrical 25,000 pound tiedowns on a unit of cargo, you measure and record the following: Chain length 75 inches Longitudinal length 60 inches Lateral length 20 inches Vertical length 24 inches How much longitudinal restraint is provided per chain?
20,000 lbs
When winching a load on a level surface, a triple-line configuration will provide __________ pounds of cable pull.
22,500
For aircraft with extended range tanks, what is the total fuel load with JP-8?
245,208
The normal pressure for the passenger oxygen system is
285-430 psi
Winch cables used with aircraft snatch blocks have a maximum diameter of __________ inch.
3/8
As a minimum, aircraft batteries can supply emergency power up to __________ minutes.
30
Each ramp heater controller cycles its heater on at a ramp temperature of __________ ° F and off at __________ °
35, 50
Replace winch cable if __________ or more broken wires per strand inch are found
4
The engine-driven hydraulic pumps provide continuous hydraulic pressure of __________ psi.
4,000
After installing four 25,000 pound chains (2 fwd, 2 aft) on a vehicle, you measure and record the following: Chain length 75 inches Longitudinal length 60 inches Lateral length 20 inches Vertical length 24 inches How much lateral restraint per chain is provided?
6,665 lbs.
The passenger oxygen system contains one __________ liter primary converter and one __________ liter auxiliary converter.
75, 75
When operating the cargo winch in the low speed and using a single line cable configuration, the winch is limited to _________ pounds of pull.
7500
For planning purposes, how many 25,000 pound chains are required for forward restraint for a vehicle which weighs 45,000 pounds?
8
Once annunciated during ascent, the WAP message CABIN PRESS LOW and the CAWS alert CABIN ALTITUDE may not rescind until a cabin altitude as low as __________ ft during descent.
8,000
Which area is a caution annunciation zone? (Graphic of WAP with A on the Caution areas, B on the Advisory area, C on the Warning area, and D on the Cue.)
A
Which electrical system component is used to join the left and right sides of the aircraft so that the AC electrical system operates in the parallel mode?
AC cross tie
During an APU fire, the warning and caution annunciation panel will display
APU
An APU fire will be indicated on which of the following panels?
APU control, aft left loadmaster, and single point refueling
You are in the cargo compartment and the APU is running. Suddenly, you hear the APU warning horn. What does the horn indicate?
APU fire
Which position of the avionics bus switch (AV BUS) enables automatic load shedding when the aircraft is on the ground with inadequate cooling?
AUTO
Which component provides automatic sequencing of the cargo door, ramp, and ramp toes operation?
Aerial Delivery System Controller
Which of the following buses is always powered even if the battery switch is OFF?
Battery direct bus
Which area is the cue display on the WAP? (shows same graphic as in Question 62)
D
A 28,000 pound load on dry shoring can be winched up a 3.8-degree incline with a double-line cable configuration
False
When the VHF/UHF backup control panel is powered on, the selected communication radio can still be tuned at the CNC.
False
Generator No. 2 is inoperative. Which component allows AC from generator 1 to power generator bus No. 2?
Generator Bus Tie
What supports the ramp when lowered to the ground for drive-in loading?
Ground support pad
In addition to the MASTER CAUTION light and the APU cue light, the indication you receive for above normal EGT reading is
HOT light
The ramp toes can be connected to the ramp in which of the following two positions?
High and low
To separate flight deck communications from cargo compartment stations, you would use the
ISOL position on the cargo/maintenance interphone isolation switchlight.
If Pax oxygen masks are deployed using the DROP switchlight below 12,500 feet cabin altitude, each -501 regulator toggle switch must be positioned to __________ after pulling the toggle stop ring to provide passenger oxygen.
MANUAL ON
Before caution messages can be manually scrolled, new caution messages must first be acknowledged by pressing the
MASTER CAUTION light.
To enable an alert start, set the APU control panel switches to
MODE SEL to ALERT and START CONTR to RUN.
In which of the following pallet positions are the retractable vertical restraint lips located?
Part of 7 and all of 8 and 9
Which panel is used to select desired speakers for an announcement or adjust PA system volume?
Passenger address control panel
What is used for emergency operation to allow restart of the APU after an automatic shutdown has occurred to provide bleed air pressure for an engine start?
Push the AUTO SHT DN ORIDE
Using Table 4E-1 in TO 1C-17A-9, compute the correct cable configuration to load a 32,300 pound load on skids on a non-skid surface up a 3.8-degree incline
Quadruple-line
To change the selected radio on the VHF/UHF backup control panel, use the __________ then press ENTER.
RT select switch
Internal winching utilizes the
RWC or winch control panels
Which of the following components is used to select and set remote cargo winch controller operating frequencies?
Receiver/Transmitter radio
During normal operation, the oxygen regulator levers will be positioned as follows
SUPPLY lever - ON DILUTER lever - 100% EMERGENCY lever - NORMAL
The normal operating configuration for the electrical system is __________ mode.
Split Parallel
Which of the following statements is a function of the cargo door?
Stows aircraft equipment
An articulating track vehicle is going to be loaded in compartment D. The following information is known about the vehicle: Vehicle weight = 24,500 lbs Number of wheels = 10 Pad area = 18 square inches Track length = 9.5 feet Given the information on the right, compute the wheel weight.
Track width = 18 inches
Using Table 4E-1 in TO 1C-17A-9, compute the cable configuration needed to load a 56,000 pound vehicle rolling on tracks up a 15-degree ramp angle
Triple-line
Because avionics cooling is critical, prompt corrective action is required
True
Less cable pull is needed to winch cargo on a level surface as opposed to an inclined surface.
True
The rotary knob on the winch control panel controls both the direction and speed at which the winch will operate.
True
When positive pressure is required, the oxygen mask must be well fitted to the face to prevent rapid depletion of the oxygen supply.
True
When the CARGO FLR HTR switch is in the AUTO position, the cargo floor heaters automatically activate if the cargo floor temperature drops below 65 degrees Fahrenheit.
True
When the cargo ramp and door are open, they provide access into the cargo compartment; closed they form a protective seal to pressurize the aircraft
True
During the Smoke/Fumes in the Aircraft checklist, what could be used to aid in filtering fumes if EPOS is not available?
Use of wet towels/cloth over the passenger's oxygen mask
w/o STRUT IMP What should you do after manually opening the strut door?
Visually check to make sure the strut door is fully open and the strut is in the vertical position
If both WCCs fail or if the WAP fails, the __________ illuminates
WACS FAIL light
Which type of message on the warning and caution annunciation panel indicates a hazardous condition that requires immediate corrective action?
Warning
The RAT, located in the forward right main gear pod, develops enough hydraulic pressure to control the aircraft for
all engine-out emergency.
On the Smoke/Fumes in the Aircraft checklist, Loadmaster's Report - "CHECK COMPLETED" (LM), indicates:
all passengers are on oxygen.
The intercom system (ICS) control panel
allows selection of microphone outputs and audio monitoring.
Circuit breaker location on the various circuit breaker panels is identified
by vertical and horizontal references.
Ensure the winch cable sheave is in alignment with the __________, properly routed through the __________ and will not interfere with other items.
cable pull; snatch blocks
The two panels at the forward loadmaster station that provide warning and caution information are the DOOR/STATUS panel and the
cargo smoke detection panel
If there is a delay while winching cargo up the ramp/ramp toes, use __________ to secure the item
chain type tiedowns
The oxygen crossfeed switch is used to
connect the crew and passenger oxygen systems
When flying through contaminated airspace, the air used for avionics cooling will be
contaminated.
The transformer/rectifiers perform the function of
converting AC power to DC power.
The warning and caution annunciation panel
displays visual warning, caution, and advisory messages for various systems throughout the aircraft.
If avionics overheat occurs on the ground and air conditioning is NOT available
do not remove electrical power from the aircraft.
The AUTO SHT DN ORIDE switchlight will override all automatic shutdowns except
fire and airspeed
The oxygen control panel for the passenger/auxiliary oxygen system is located at the __________ loadmaster station.
forward
Passenger address (PA) control panels are located in the cockpit and at the
forward and aft left loadmaster stations
Sufficient oxygen must be on board before takeoff to fly
from ETP to the suitable recovery field using 100% oxygen.
Personnel will wear__________ when handling the winch cable.
gloves
Ensure the __________ is clear prior to extending the stabilizer struts.
ground area
The cargo winch is powered
hydraulically.
The APU OIL indication on the WAP may mean the APU
oil pressure is low
The remote cargo winch controller is stored
on the Sure-Comm rack
The primary source of oxygen for the crew system is __________ liquid oxygen converter(s).
one 25-liter
Control panel used for backup communications is located on the
overhead panel
The ORIDE switch on the cargo winch control panel
overrides the remote winch control
An item of cargo weighing 68,000 pounds with hard rubber wheels would require a __________ -line configuration in order to be winched up a 15- degree angle.
quadruple
The CREW OXY LOW warning illuminating on the WAP indicates the oxygen
quantity remaining is less than 5 liters or supply pressure is below 60 +/- 5 psi
The engine-driven hydraulic pumps are located in the
respective engine accessory gear box.
A skidded item of cargo being pulled across the cargo ramp is an example of __________ friction.
sliding
When using the DC electrical system, the __________ configuration is the normal mode for operation.
split-parallel
Use the AF Form 15 or Standard Form 44 when
the AIR Card is not accepted
Circuit breakers will open if
the amount of electricity in the circuit breaker is more than the breaker can tolerate
If the aircraft loses cabin pressure, the aircraft commander will descend
to the lowest practical altitude below FL250
The primary purpose of the __________ pump is to assist in landing gear retraction or cargo door/ramp closing in the event of No. 2 or 3 engine loss.
transfer
The fuel management system
transfers fuel from inboard to outboard tanks until all quantities are equal
If avionics overheat persists and an AVIONICS OVERHEAT WAP caution occurs after placing AVIONICS COOL ORIDE in the OPEN position with the air conditioning pack(s) on,
turn the avionics check valve handle toward the open position until the valve is completely open
There is/are __________ engine driven hydraulic pump(s) per system, located on and driven by their respective engine accessory gearbox.
two