variable load

Ace your homework & exams now with Quizwiz!

Substation

where the power generated steps up or down.

ideal load

An ____ on the station would be one of constant magnitude and steady duration.

planimeter

Area under the load curve can be measure by a ____.

more reliable

Hydro units are ____ than steam units.

steam accumulation

In an industrial process, _____ maintains more constant steam pressure.

size and cost

The ____ of Diesel engine are strong adverse factors.

capacity factor

The ____ of peak load unit is very nearly zero.

daily steam consumption

The area under the boiler load curve is the ____

energy demanded

The area under the load duration curve represents the ____ by the system.

monthly and annual load curve

The most important variations of load curve are the _____

Large hydroelectric units

are not able to respond to sudden swing of loads.

Ruths accumulator

can be called a steam accumulator.

exhaust gas

can be used in raising the capacity of an adjacent steam plant.

Hydraulic accumulators

carry steam station peaks.

Gas turbine plants

eliminate long warm-up fuel cost.

compact gas turbine unit

has low thermal efficiency.

Gas turbine plants

have a high rotational speed which results in low generator cost.

Internal combustion power plants

have been advocated as peak load units.

Heat accumulator systems

have been devised to smooth out fluctuations.

Battery reserve

incurs heavy first cost and maintenance per kWhr of storage.

Variable load

is a non-steady load demand

power station

is designed to meet the load requirements of the consumers

power station

is designed to meet the load requirements of the consumers.

Power factor

is employed to describe certain technical aspects of AC circuits.

Annual load curve

is for annual load factor.

Monthly load curve

is sometimes used in establishing rates.

Demand factor

is the actual maximum demand of the customer between the connected loads.

Daily load factor

is the average load over the day divided by the maximum peak.

Monthly load curve

is the average of the daily load curves over a month.

Annual load curve

is the average of the daily load curves over a year.

Peak load

is the maximum electrical power demand.

Base load

is the minimum level of demand on an electrical grid.

Load curve

is the operating data of demanded load plotted against time sequence.

Plant capacity factor

is the relation between actual energy produced and the maximum energy to be produced during a period.

Plant use factor

is the relation between the energy production and the capacity of the plant during operations.

Diversity factor

is the relation between the total individual maximum demands of the subdivision and the maximum simultaneous demand of the system.

Load factor

is the relation of average load to the maximum load demand

Connected load

is the sum of the continuous ratings of all equipment connected to a supply system

Load duration curve

is useful in financial studies.

Feeders

may each supply several distribution transformers.

Obsolete equipment

may have sufficient capacity to carry short peaks.

Spinning Reserve

represents equipment standing by at normal operating conditions.

Storage battery

requires rotary conversion in a-c system

Load curve

shows the varying load with respect to time

Traction system

uses direct current, for speed control reasons


Related study sets

chapter 6 organization and management

View Set

Fluid Volume Deficit: Hypovolemia

View Set

Research Methods: Ch's 4-6, & 15

View Set

Health Assessment in Nursing, chapter 1

View Set

Power points: Project Management GR 1

View Set

Physical geography chapter 13 review

View Set

Supreme Court, Key Cases, Shelby County v Holder

View Set