410

¡Supera tus tareas y exámenes ahora con Quizwiz!

directly below

An electric discharge or LED Luminaire or listed assembly can be cord connected if the Luminaire is located [_____] cord is visible for its entire length, except at termination, and the cord is not subject to strain or physical damage.

3

Branch circuit conductors within how many inches of a ballast shall have an insulation temperature rating no lower than 90° C?

maintained

Covers for Luminaires shall be located so that the lamps and Equipment can be properly installed and what?

Shall be installed.

For existing installed Luminaries without disconnecting means in indoor locations, other than dwellings and Associated accessory structures, a disconnecting means [_____] in fluorescent Luminaires that utilize double-ended lamps, typical fluorescent lamps, at the time a ballast is replaced.

20 feet (410.30 B1 ex:2)

Handholds in poles supporting Luminaires shall not be required for poll Less in height of a finish grade if the poles are provided with a hinge base and a minimum of what height?

6 inches

In clothes closets, recessed incandescent or LED Luminaires with a completely enclosed light source can be installed in the wall or ceiling, provided there is a minimum clearance of how many inches between the nearest point of the storage space?

Luminaires that provide emergency illumination required in 716.16

In indoor locations other than dwellings and Associated accessory structures, fluorescent Luminaires that utilize double-ended lamps (typically fluorescent lamps, and contain ballasts that can be serviced in place) shall have a disconnecting means except for what type?

true

Luminaires made of insulating material that are directly wired or attached to outlets supplied by a wiring method that does not provide a ready means for grounding attachment to an equipment grounding conductor shall be made of insulating material and shall have no exposed conductive Parts, true or false?

true

The NEC allows a lighting Outlet on the wall in a Clothes Closet when it is at least 6 inches away from storage space, true or false?

18 in

The Raceway or cable for tap conductors to recessed Luminaires shall have a minimum length of what?

6 pounds (410.30 A)

The maximum weight of a Luminaire permitted to be supported by the screw shell of a lampholder is how many pounds?

In wet or damp locations, or where likely to be subjected to physical damage.

Track lighting shall not be installed when what?

true

True or false, Lumineers that require adjusting or aiming after installation can be cord connected without an attachment plug provided. The exposed cord is suitable for hard usage or extra hard usage and is not longer than that required for maximum adjustment.

false (410.151 A)

True or false, lighting track fittings can be equipped with general-purpose receptacles?

damp or wet

lamp holders installed in damp locations shall be listed for use in what locations?

wet locations

lamp holders installed in wet locations shall be listed for use in what locations?

raceways, type MC, AC, Mi, or NM cable, or flexible cords.

Electric discharge and led Luminaires supported independently of the outlet box shall be connected to the branch circuit through what type of systems?

true

Lamp holders of the screw shell type shall be installed for use as lamp holders only, true or false?

combustible material

Lamp holders shall be constructed, installed, or equipped with shades or guards so that [_____] is not subjugated to temperatures in excess of 90 degrees C?

4 feet

Lighting track shall have two supports for a single section of [_____] feet or shorter in length and each individual section of not more than 4 feet attached to it. Shall have one additional support, unless the track is identified for supports at greater intervals.

5

Lighting track shall not be installed less than how many feet, above the finished floor except where protected from physical damage or where the track operates at less than 30 V RMS, open circuit voltage?

table 250.122

Luminaires and Equipment shall be mechanically connected to an equipment grounding conductor as specified in 250.180, And shall be sized in accordance with what?

bolts, screws, and rivets. (410.36 B)

Luminaires attached to the framing members of a suspended ceiling shall be secured by the framing members by mechanical means such as what?

commercial

Luminaires can be installed in a commercial cooking Hood if the Luminaire is identified for use within what type of cooking Hood?

type O lamp

Luminaires containing a metal halide lamp, other than a thick glass PAR lamp, shall be provided with a containment barrier that encloses the lamp, or shall be provided with a physical means that only allows the use of what lamp type?

recognized wiring methods

Luminaires designed for end-to-end assembly, or Lumineers connected together by what, can contain a two wire branch circuit, or one multi wire branch circuit, supplying the connected Luminaires? One additional two wire branch circuit separately supplying one or more of the connected Luminaires is permitted.

through wiring

Luminaires identified for [_____], with an integral outlet box in accordance with 410.21 shall be permitted to be used as a conductor Raceway.

mercury vapor, metal halide, fluorescent.

Luminaires lamps that, are subjugated to physical damage and installed in playing and spectator seating areas of indoor sports, mixed-use, or all-purpose facilities, shall be of the type that protects the lamp with a glass or plastic lens. What lamps are these?

subject to shower spray

Luminaires located within the actual outside dimension of a bathtub and shower shall be marked for damp locations, or marked for wet locations where they are....

the screw shell. (410.50)

Luminaires shall be wired so that what part of each lamp holder is connected to the same Luminaire or circuit conductor terminal?

equipment grounding conductor

Metal raceways shall be bonded to the metal pole with what grounding system?

8 feet

No parts of cord connected Luminaires, chains, cable, or cord suspended Luminaires, lighting track, pendants, or paddle fans shall be located within a Zone measured 3 ft horizontal or [_____] feet vertically from the top of the bathroom rim or the shower stall threshold. .

true

True or false, if more than one luminar is installed on a branch circuit that is not of the multiwire type, a disconnecting means is not required for every luminar when the light switch or the space ensures that some of the Luminaire in the space will still provide illumination?

true

True or false, outdoor Luminaires and Associated equipment can be supported by trees?

true

True or false, when connected to multi wire Branch circuits, the fluorescent Luminaire disconnect shall simultaneously break all Supply conductors of the ballast, including the grounded conductor?

listed. (410.36 B)

What Clips are identified for use with the type of ceiling framing members and Luminaires that shall be permitted to be used to secure Luminaires to the ceiling framing members?

Surface mounted or recessed incandescent Luminaire with completely enclose light source, fluorescent Luminaire, or LED Luminaire with a completely enclosed light source. (410.16 A1&2)

What types of Luminaires can be installed in a Clothes Closet?

true

When Electric discharge and led Luminaires that are designed not to be supported solely by the outlet box are surface mounted over a concealed outlet box, the Luminaire shall provide access to the wiring within the outlet box by means of suitable openings in the back of the Luminaire, true or false?

Decorative lighting Products, lighting accessories for temporary seasonal and holiday use, and portable flexible lighting Products.

article 410 covers Luminaires, portable Luminaires, lamp holders, pendants, incandescent filament lamps, Arc lamps, Electric discharge lamps, and what else, besides the wiring and Equipment forming part of such products and lighting installations? 410

6 ft

closet storage space is defined as a volume bounded by the sides and back closet walls extending from the highest clothes hanging rod at a horizontal distance of 2 ft from the sides and back of the closet walls and the closet floor vertically to the height of what?

12in for surface mounted incandescent or LED Luminaires with a completely enclosed light source, 6in for surface mounted fluorescent Luminaires, and 6 in 4 recessed fluorescent Luminaires or recessed incandescent or LED Luminaires with a completely enclosed light source.

each Luminaire shall maintain a minimum clearance from the closet storage space of what for each type?


Conjuntos de estudio relacionados

Biochem Tinker Lab: Organic Compounds Indicator and Hydrocarbon

View Set

9th Grd Biology Unit 3 Test Study Guide

View Set

Chapter 3: Collecting Objective Data: The Physical Examination PrepU Quiz and answers

View Set

Security + Threats, Attack and Vulnerabilities

View Set

2023 Nissan titan XD Certification

View Set

BUSM60 Quiz 2 Version 19 Study guide

View Set

Medical-Surgical Assignment Exam

View Set

Live Virtual Machine Lab 3.3: Module 03 NTP Server Management

View Set