Ch. 9 & 10 Printreading for Residential and light commercial

अब Quizwiz के साथ अपने होमवर्क और परीक्षाओं को एस करें!

One volt ampere is equal to ______________ watts

1

An ____ gal hot water tank provides water service throughout the building.

100

One MBH is equal to ______________ Btu per hour

1000

The maximum distance between control joints in the floor slab is _____

15'

Cat boarding 207 has one ______________ CFM ceiling exhaust fan that is described in the exhaust fan schedule.

150

The upper roof area has a perimeter elevation of ______ above the finish floor.

26'

A roofing membrane is attached with a required minimum _____" overlap between the adjoining sheets.

3

The concrete and reinforcement notes in the general notes, sheet 5-01 indicate that the footing and foundation concrete must reach a compressive strength of ______ psi in 28 days.

3000

Twenty-four inch diameter PVC piping is installed with a ___% grade under the parking lot with a series of manholes and catch basins.

5

A ______________" diameter service line is provided for fire protection throughout the building.

6

Each parking lot light is supported by a 24" diameter concrete pier that must be a minimum of _____" below the surface

60

Each parking lot light is supported by a 24" diameter concrete pier that must be a min of ______________ below the parking lot surface.

60"

The _______ ____ __________ Establishes guidelines for accessibility to places of public accomodation and commercial facilities by individuals with disabilities.

ADA

An ____________ is a revised drawing that is prepared by a contractor at the conclusion of a project.

As-built

____________ locations are indicated with heavy broken lines on the second and lower roof framing plan.

Bar joist

an ______________ is a battery-powered light that automatically turns on if a building experiences a power outage.

Battery emergency light

______________ on the panel GP-1 circuit indicates that it has a CB lock

Circle

A ____________ is constructed near the southernmost skylight to diver water around the skylight and toward the roof drain.

Cricket

The floor plan and gridlines on the second floor plan appear as gray shaded lines, and the ______________ is shown as black lines

Electrical lighting

T or F A different gridline system is used on the second floor plan as the foundation plan and the first floor plan.

F

T or F Light fixtures to be installed around the outside of the building are shown with circles containing letters that relate to the electrical fixture schedule located on specifications-Electrical, sheet E-7

F

T or F Seer is the amount of cooling produced by a system for all the energy it consumes.

F

T or F The foundation plan shows both the underground work that needs to be completed at the beginning of the project for storm and sanitary sewer piping and surface paving work to be completed near the end of the project

F

T or F The grading and utility plan includes both the concrete foundation work and the structural steel information for the project.

F

T or F The no. 8 wire in the perimeter lighting circuit is for the ground wire

F

T or F Waterproof audible/visual emergency lights are installed in an east/west direction in cage 141 and powered by circuit 9

F

The lettered and numbered gridlines on the _______ plan provide a system for identifying and locating structural steel columns.

Foundation

Curbs and pavement for the parking area are shown on the _____ plan.

Grading and utility

The ____________ plan shows the connections of roof drains and surface drains into an integrated storm water system

Grading and utility

Existing surface drain piping and inlets are to be disabled and filled with ____________

Gravel

Sheet ______________ provides information about the HVAC installation for the second floor zone.

M-2

Each circuit breaker is described in terms of the trip amperes per CB and the ______________

Number of poles

The ____________ plan provides a plan view of the roof structure, a variety of detail drawings, and general notes about the roof installation.

Roof

_________ locations are shown with heavy solid lines

Steel beam

T or F A battery standby exit sign, indicated as fixture type F7 or F33 on the prints, is an exit sign that uses a battery as a backup power source if the building experiences a power outage.

T

T or F All exterior wall and interior partition dimensions are given on the first floor plan.

T

T or F On sheet P-1, cold water piping is indicated by a broken line with one dash, while hot water piping is indicated by a broken line with two dashes.

T

T or F Sheet M-1 indicates that the exhaust fans connect to a 10" diameter vertical duct above room 111 and another 10" diameter vertical duct above room 116

T

T or F Signage is shown on the exterior elevation drawings.

T

T or F The 2001 city of chicago electrical code is the governing code for this work as shown on the tile sheet of the prints, so all recep locations and spacing must be performed in accordance with this code.

T

T or F The mounting method, voltage, number of phases, and wire are shown at the top left side of an electrical panel chart.

T

T or F The title page lists all of the key entities involved in a project, such as the structural engineer, civil engineer, construction management firm, landscape architect, and mechanical engineer.

T

T or F Solid lines on the door into the sprinkler room indicate the hinged side of the door.

T

The two isolation rooms have similar power configurations, each having an exhaust fan controlled by a wall switch near the door and one GFCI outlet

T

______________ is generally measured at the point where airflow enters the equipment and where the airflow exits the equipment

Total external static pressure

Interior footings are indicated with dashed lines on the ____________ plan

foundation

Indoor yard/boarding 151 has two sets of _____ installed in the southwest and northeast corners.

house bibbs

An ____________ is shown as jan. 105 and has a slop sink.

janitors closet

______ is a groove in a lift or placement of concrete that is filled with concrete of the next lift

keyway

The ______________ is the highest amount of steady-state electrical current that an RTU should see when operating correctly.

minimum circuit amps

There are ______________ heating/cooling zones in the vet center.

seven

The legal description for the property appears at the top of the ____________

topographical survey


संबंधित स्टडी सेट्स

mgmt chapters 5-12 lecture and hw notes

View Set

CompTIA A+ Chapter 15, Maintaining and Optimizing Operating Systems

View Set